NX Routing Services
NX Routing Services: Wire Harnesses, Piping and Tubing Designed in Siemens NX
NX routing services are engineering services for the routed systems inside a machine or vehicle, designed in Siemens NX: wire harnesses and cables in NX Routing Electrical, and pipes, tubes and ducts in NX Routing Mechanical. Our NX design engineers route in your assemblies and to your standards, build the routing part libraries and specifications behind the work, and automate repetitive routing steps with NXOpen. An engineer checks and releases every routed assembly.
Short answer
NX Routing is the group of Siemens NX applications for designing routed systems in 3D: wiring harnesses and cables, piping, tubing and HVAC ducts. Our NX design engineers do the routing; NXOpen developers automate what repeats.
inteliScience is a Siemens NX, NXOpen and Teamcenter specialist with an NX design team delivering nearshore from Romania.
This page is about routing as a service: harness and piping design capacity, libraries and automation. If you want to learn the commands yourself, start with our NX routing tutorial, or train your team in our NX Routing Training. How 3D routing in NX shares the work with an electrical design tool is covered in our comparison of NX Routing with dedicated electrical CAD. The service belongs to our NX CAD design services.
Why routed systems cost time in NX projects
Routing comes late in a machine design. The frame, the drives and the sheet metal are placed first, and then the harnesses, tubes and pipes have to find their way through what is left. Every later change to the mechanical design moves a path, changes a length or blocks a clip position. That is why routing work tends to pile up shortly before release.
- Incomplete libraries. If a connector or fitting is not in the routing part library with correct ports and attributes, designers model a placeholder. The 3D model looks right, and the bill of materials is wrong.
- Lengths for manufacturing. Harness shops cut to the lengths on the formboard; pipe shops bend to the bend report. A routed model is only useful when these figures come out of it reliably.
- Repeated variants. In machine building, many orders carry their own harness variant. The same manual steps run again for every order.
- Specialist knowledge. Few NX designers route every week, so the routing know-how often sits with one or two people.
What our NX routing services deliver
Routed harnesses and cables
Paths, bundles and wires routed in NX Routing Electrical from your connection list, with wire lengths and bundle diameters calculated in the model.
Formboard drawings
The 3D harness flattened into formboard drawings for harness manufacturing, with your drawing template, tables and the lengths the shop cuts to.
Piping and tubing runs
Runs routed in NX Routing Mechanical against your specification, checked for bend radius, minimum length and connection compatibility.
Routing part library
Connectors, clips, fittings, elbows and stock set up with ports and attributes, and specifications per discipline that filter what designers can place.
NXOpen routing tools
Repetitive steps as commands in your NX: segment separation, length lists, exchange files with fixed settings, library alignment, release checks.
Data to ECAD, PLM and the shop
Connection lists with lengths back to electrical design, routing data and BOM into Teamcenter, drawings and reports to manufacturing.
How an NX routing project runs
Whether the job is one harness or a series of machine variants, the work follows the same steps. The library comes before the first path, because a routed assembly is only as good as the parts it is built from.
NX routing: one connection list or specification, one routed assembly, one engineer who releases it
Assembly and inputs
Your NX assembly, the connection list or schematic, your standards and the current state of your routing library.
Parts and specifications
Missing connectors, clips and fittings built with ports and attributes; specifications set per discipline.
Routed and checked
Paths, stock and standard parts placed in NX; design rules, clearances and lengths checked.
Released and handed over
Formboards, bend reports, BOM and exchange files, reviewed and released by the engineer.
No length is typed by hand. Wire lengths, bundle diameters and pipe lengths come from the routed NX model, so a design change produces new figures instead of an outdated table.
Free · 45 minutes · live demo · no obligation
Free Intro Call with Live Demo
A screen-share session with an inteliScience NX engineer, walking through your routing process from connection list or specification to released documents.
- 45 minutes by screen share, no system access needed
- Every finding classed as a method, training or automation topic
- A live demo of AI and automation in NX
Free of charge · with an NX engineer, not a salesperson
For a defined routing job
Fixed quote after a short call
Send us one assembly with its connection list or specification. We scope it in a short call and send a fixed quote for routing, library work or automation.
- Scope, deliverables and turnaround in writing
- For a deeper review of your NX process: the NX Engineering Assessment, a one-week review at €4,900 fixed
Automating repetitive routing tasks with NXOpen
The routing itself rarely needs automation. The steps around it do: preparing data, separating segments, producing length lists, running exchanges and keeping libraries in sync. NXOpen gives programmatic access to routing objects such as runs, stock, ports and paths, so these steps can run as commands inside your NX session. More on the general approach is on our NXOpen automation page.
There is no AI in these tools, and that is deliberate. Lengths, exchanges and library rules must give the same result every time. Where AI helps in NX work, it assists people and does not decide what gets manufactured.
Our team’s experience in NX electrical routing
Our NX electrical routing automation case study describes the three tools and the results: the hand-off pass per routed assembly went from several hours to a few minutes, PLMXML export errors became rare exceptions, and about 50 users work with the toolchain.
What NX routing services do not do
- No electrical schematic design. Circuit logic, wire gauges and protection stay with your electrical engineers. We take the connection list and return lengths.
- No routing without an engineer. Automation prepares, checks and documents. An NX design engineer routes and releases.
- No library from nowhere. Routing parts need correct supplier data. Where data is missing, we ask for it instead of guessing dimensions.
- No plant-wide process piping. Our focus is routed systems inside machines, vehicles and equipment designed in NX.
- No harness or pipe manufacturing. We deliver the drawings, lists and data your shop or supplier builds from.
- No changes to your release rules. Release states and approvals stay in your PLM process.
Where the work runs, and who owns the results
Routing needs the matching NX routing licenses, and the work happens in an environment you approve: on your NX installation through a remote workstation or VDI, or as agreed per project under NDA. Your libraries, specifications, routed assemblies and drawings belong to you.
Frequently asked questions about NX routing services
What is NX Routing in Siemens NX?
What is the difference between NX Routing Electrical and NX Routing Mechanical?
Can Siemens NX create formboard drawings for wire harness manufacturing?
Can routing tasks in Siemens NX be automated with NXOpen?
NX Routing vs. electrical CAD for harness design: which tool does what?
What drives the cost of outsourcing NX harness or piping design?
Name the harness or piping system that slows your team down.
Send us one routed assembly or one connection list. We will tell you what is library work, what is routing capacity and what is worth automating with NXOpen.
Talk to an NX Engineer Or book the free intro callSiemens NX design engineers · nearshore from Romania, one hour ahead of CET · under NDA

