Contacts
Get in touch
Close

Contacts

Romania, Cluj-Napoca – 400157
Str. Ploiești Nr. 9

Romania, Vama – 447350
Str. Fermei Nr. 14

+40 774 463 429

info@inteliscience.net

NX Routing Services

NX Routing Services

NX Routing Services: Wire Harnesses, Piping and Tubing Designed in Siemens NX

NX routing services are engineering services for the routed systems inside a machine or vehicle, designed in Siemens NX: wire harnesses and cables in NX Routing Electrical, and pipes, tubes and ducts in NX Routing Mechanical. Our NX design engineers route in your assemblies and to your standards, build the routing part libraries and specifications behind the work, and automate repetitive routing steps with NXOpen. An engineer checks and releases every routed assembly.

Short answer

NX Routing is the group of Siemens NX applications for designing routed systems in 3D: wiring harnesses and cables, piping, tubing and HVAC ducts. Our NX design engineers do the routing; NXOpen developers automate what repeats.

inteliScience is a Siemens NX, NXOpen and Teamcenter specialist with an NX design team delivering nearshore from Romania.

This page is about routing as a service: harness and piping design capacity, libraries and automation. If you want to learn the commands yourself, start with our NX routing tutorial, or train your team in our NX Routing Training. How 3D routing in NX shares the work with an electrical design tool is covered in our comparison of NX Routing with dedicated electrical CAD. The service belongs to our NX CAD design services.

Why routed systems cost time in NX projects

Routing comes late in a machine design. The frame, the drives and the sheet metal are placed first, and then the harnesses, tubes and pipes have to find their way through what is left. Every later change to the mechanical design moves a path, changes a length or blocks a clip position. That is why routing work tends to pile up shortly before release.

  • Incomplete libraries. If a connector or fitting is not in the routing part library with correct ports and attributes, designers model a placeholder. The 3D model looks right, and the bill of materials is wrong.
  • Lengths for manufacturing. Harness shops cut to the lengths on the formboard; pipe shops bend to the bend report. A routed model is only useful when these figures come out of it reliably.
  • Repeated variants. In machine building, many orders carry their own harness variant. The same manual steps run again for every order.
  • Specialist knowledge. Few NX designers route every week, so the routing know-how often sits with one or two people.

What our NX routing services deliver

01 · Electrical

Routed harnesses and cables

Paths, bundles and wires routed in NX Routing Electrical from your connection list, with wire lengths and bundle diameters calculated in the model.

02 · Formboard

Formboard drawings

The 3D harness flattened into formboard drawings for harness manufacturing, with your drawing template, tables and the lengths the shop cuts to.

03 · Mechanical

Piping and tubing runs

Runs routed in NX Routing Mechanical against your specification, checked for bend radius, minimum length and connection compatibility.

04 · Library

Routing part library

Connectors, clips, fittings, elbows and stock set up with ports and attributes, and specifications per discipline that filter what designers can place.

05 · Automation

NXOpen routing tools

Repetitive steps as commands in your NX: segment separation, length lists, exchange files with fixed settings, library alignment, release checks.

06 · Handover

Data to ECAD, PLM and the shop

Connection lists with lengths back to electrical design, routing data and BOM into Teamcenter, drawings and reports to manufacturing.

How an NX routing project runs

Whether the job is one harness or a series of machine variants, the work follows the same steps. The library comes before the first path, because a routed assembly is only as good as the parts it is built from.

NX routing: one connection list or specification, one routed assembly, one engineer who releases it

Intake

Assembly and inputs

Your NX assembly, the connection list or schematic, your standards and the current state of your routing library.

Library

Parts and specifications

Missing connectors, clips and fittings built with ports and attributes; specifications set per discipline.

NX design engineer

Routed and checked

Paths, stock and standard parts placed in NX; design rules, clearances and lengths checked.

Documents · handover

Released and handed over

Formboards, bend reports, BOM and exchange files, reviewed and released by the engineer.

No length is typed by hand. Wire lengths, bundle diameters and pipe lengths come from the routed NX model, so a design change produces new figures instead of an outdated table.

Free · 45 minutes · live demo · no obligation

Free Intro Call with Live Demo

A screen-share session with an inteliScience NX engineer, walking through your routing process from connection list or specification to released documents.

  • 45 minutes by screen share, no system access needed
  • Every finding classed as a method, training or automation topic
  • A live demo of AI and automation in NX
Book the free intro call

Free of charge · with an NX engineer, not a salesperson

For a defined routing job

Fixed quote after a short call

Send us one assembly with its connection list or specification. We scope it in a short call and send a fixed quote for routing, library work or automation.

  • Scope, deliverables and turnaround in writing
  • For a deeper review of your NX process: the NX Engineering Assessment, a one-week review at €4,900 fixed
Ask for a routing quote

Automating repetitive routing tasks with NXOpen

The routing itself rarely needs automation. The steps around it do: preparing data, separating segments, producing length lists, running exchanges and keeping libraries in sync. NXOpen gives programmatic access to routing objects such as runs, stock, ports and paths, so these steps can run as commands inside your NX session. More on the general approach is on our NXOpen automation page.

There is no AI in these tools, and that is deliberate. Lengths, exchanges and library rules must give the same result every time. Where AI helps in NX work, it assists people and does not decide what gets manufactured.

Our team’s experience in NX electrical routing

Our NX electrical routing automation case study describes the three tools and the results: the hand-off pass per routed assembly went from several hours to a few minutes, PLMXML export errors became rare exceptions, and about 50 users work with the toolchain.

What NX routing services do not do

  • No electrical schematic design. Circuit logic, wire gauges and protection stay with your electrical engineers. We take the connection list and return lengths.
  • No routing without an engineer. Automation prepares, checks and documents. An NX design engineer routes and releases.
  • No library from nowhere. Routing parts need correct supplier data. Where data is missing, we ask for it instead of guessing dimensions.
  • No plant-wide process piping. Our focus is routed systems inside machines, vehicles and equipment designed in NX.
  • No harness or pipe manufacturing. We deliver the drawings, lists and data your shop or supplier builds from.
  • No changes to your release rules. Release states and approvals stay in your PLM process.

Where the work runs, and who owns the results

Routing needs the matching NX routing licenses, and the work happens in an environment you approve: on your NX installation through a remote workstation or VDI, or as agreed per project under NDA. Your libraries, specifications, routed assemblies and drawings belong to you.

Frequently asked questions about NX routing services

What is NX Routing in Siemens NX?
NX Routing is the group of Siemens NX applications for designing routed systems in 3D: Routing Electrical for wiring harnesses and cables, and Routing Mechanical for piping, tubing, HVAC ducts, conduit and raceways, with Routing Logical for 2D diagrams. Routed systems are built along centerline paths through the NX assembly: stock is assigned to the paths, and standard parts from a routing part library connect it. NX routing services apply these tools to your assemblies, libraries and standards.
What is the difference between NX Routing Electrical and NX Routing Mechanical?
Routing Electrical is for electrical systems: wiring harnesses, wires and cables between connectors, connection lists, and formboard drawings for harness manufacturing. Routing Mechanical is for fluid and structural systems: tubes, pipes, conduit, raceways and HVAC ducts, with design rule checks such as minimum bend radius, bills of materials and bend reports. Both share the same routing base of paths, stock and standard parts, which is why one library strategy can serve both.
Can Siemens NX create formboard drawings for wire harness manufacturing?
Yes. Formboard in NX Routing Electrical creates a flattened 2D representation of the 3D harness model for manufacturing drawings, and Update Formboard refreshes it from the latest 3D harness data. Layout tools orient branches, shape segments and rotate components on the board. Several harnesses can go on one formboard when they are connected through shared geometry or port-to-port connections. In our projects, formboards are built in your drawing template with the tables your harness shop uses.
Can routing tasks in Siemens NX be automated with NXOpen?
Yes. The NXOpen API includes a Routing namespace, available in .NET, C++ and Python, with classes and builders for routing objects such as runs, stock, ports and paths. Typical candidates are the steps around the routing: separating segments for exact lengths, running data exchanges with fixed settings, keeping libraries aligned, producing length lists and checking attributes before release. Our team has built such tools for electrical routing, and they run as commands in the user’s NX session.
NX Routing vs. electrical CAD for harness design: which tool does what?
They do different jobs and usually work together. An electrical CAD system defines the circuit logic: schematics, wire connections, wire types and protection. NX Routing defines the physical harness in the 3D machine assembly: where wires run, how long they are, how thick the bundles are and how the formboard looks. The connection list is the link between the two: it comes from the electrical side and goes back with lengths from NX.
What drives the cost of outsourcing NX harness or piping design?
The effort per routed assembly, which depends on the number of connectors, wires or runs, the state of the routing library, how often the surrounding design still changes, and how detailed the required documents are. A clean library and a stable assembly make routing much faster than a job where parts must be built first. We quote a fixed price per defined job after reviewing one sample assembly with you.

Name the harness or piping system that slows your team down.

Send us one routed assembly or one connection list. We will tell you what is library work, what is routing capacity and what is worth automating with NXOpen.

Talk to an NX Engineer Or book the free intro call

Siemens NX design engineers · nearshore from Romania, one hour ahead of CET · under NDA

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.