Contacts
Get in touch
Close

Contacts

Romania, Cluj-Napoca – 400157
Str. Ploiești Nr. 9

Romania, Vama – 447350
Str. Fermei Nr. 14

+40 774 463 429

info@inteliscience.net

NX Upgrade Checklist: What to Test Before a New Release

NX Upgrade Checklist: The Short Version

An NX upgrade checklist lists everything that touches Siemens NX (customer defaults, templates, NXOpen programs, CAM postprocessors, Teamcenter integration, add-ons, licenses, training) and how each is tested before a new functional release goes live. inteliScience runs NX release upgrades from Cluj-Napoca. Result: production switches on a fixed date, without surprises.

Area What to inventory How to test before go-live
Customer defaultsSite and group .dpv files, locksImport into the new release, review new defaults with Find Default
Templates and standardsPart, assembly and drawing templates, PAX files, drafting standardsCreate one file from every template, check the title block
NXOpen programs and journalsCompiled tools, journals, Knowledge Fusion, UDFsRecompile and re-sign, run a regression set of parts
CAMPostprocessors, machine kits, CAM templates, tool libraryPost reference programs, compare the NC output line by line
TeamcenterIntegration settings, managed templates, attribute mappingsSave, check in, revise and clone in a test environment
Add-ons and environmentPartner tools, translators, custom_dirs.dat, environment variablesStart every add-on and run one real task
Licenses and platformLicense file for the new release, server version, OS, driversStart every module you own on a reference workstation
PeopleWho uses which changed commandsDelta training before go-live

The Problem: The Install Takes an Hour, the Surprises Take Weeks

Installing a new NX release is the easy part: a functional release goes into its own directory and runs next to the old one. The cost sits in what your company has built around NX, from settings and templates to programs, posts and integrations. Siemens’ installer tests none of it, and the people who built it have often moved on.

The rhythm makes this a recurring job. Siemens introduced Continuous Release in 2019, with a functional release every six months and monthly updates in between, and has named releases by year and month since NX 2206. The current release is Designcenter 2606, announced on 23 June 2026. The next one, 2612, was shown in Siemens’ early access program from 31 August to 25 September 2026. A team that wants to stay current upgrades every six to twelve months.

What breaks is rarely the obvious thing. Our team once had to build a small tool because the NX color palette had changed between versions: older parts opened in the new release with the wrong colors, and color carried meaning in that company’s models. Nobody had a test for it, because nobody expected colors to change. Most upgrade surprises look like that, and finding them before go-live is the point of every NX release upgrade we run.

Functional Release or Monthly Update: How Much Testing Each Needs

Monthly updates within a release series are cumulative, update the existing installation and leave Teamcenter and Active Workspace compatibility unchanged, so a short smoke test is enough. A functional release installs separately, needs a license that covers it, can change NXOpen and prerequisites, and gets the full NX upgrade checklist.

Monthly update (for example 2606.x) Functional release (for example 2512 to 2606)
InstallationUpdates the existing directory, cumulativeNew directory, runs next to the old release
LicenseCovered by the license for the seriesNeeds a license that covers the new release
NXOpen binariesRun unchanged within the release familyRecompile, relink and re-sign
Teamcenter and Active WorkspaceCompatibility unchangedCheck the support matrix
Part filesOpen across the monthly updates of the seriesParts saved in the new release do not open in the older one
Test depthSmoke test on reference partsFull checklist and pilot

Two dates frame the plan. Monthly updates for a release series run through its standard maintenance period, which Siemens’ documentation puts at about a year after the functional release. And under Siemens’ maintenance terms, Siemens maintains the current version plus the latest point release of the previous one. You may skip releases (moving from 2412 straight to 2606 works), but our recommendation is at least one functional release upgrade per year, so you never fall out of both windows at once.

The NX Upgrade Checklist Inventory: Everything That Touches NX

Take the inventory before you install. List every file, variable, program and connection that changes how NX behaves, each with an owner. The surprises come from items nobody knew existed: a DLL in a startup folder, a group defaults file, a journal on a shared drive that one department runs every Friday.

  1. Customer defaults: site and group .dpv files, the locks in them, and how many user files deviate.
  2. Templates and standards: template parts, PAX files, drafting and PMI standards, borders and title blocks, ideally outside the installation directory.
  3. Environment: changes to ugii_env.dat, all UGII_* variables, custom_dirs.dat (by default in the ugii\menus folder of the installation) and every directory it lists, with their startup, application, udo, udf and dfa subfolders.
  4. NXOpen and automation: compiled tools (C#, C++, Java), Python and VB journals, Knowledge Fusion classes, UDFs, menus and roles.
  5. CAM: postprocessors, machine kits, CAM setup templates, the tool and machine library.
  6. Teamcenter: NX integration settings, Teamcenter-managed templates, attribute mappings, Active Workspace use from NX.
  7. Add-ons: partner applications, translators, PDM connectors, CAM App Hub apps.
  8. Licenses: the license file for the new release, bundles, server version.
  9. Platform: operating system, graphics drivers, the WebView2 browser NX has used since NX 2412, runtimes such as the Visual C++ redistributable and a 64-bit Java 11 runtime for Java-based NX products (the NX 2506 requirements).
  10. People: who uses which applications, so training targets the commands that changed.

The script below collects most of the technical part from a workstation. It only reads. Because NX can define variables in ugii_env.dat that Windows does not see, it also stores the output of NX’s own env_print -all utility.

# Read-only inventory of what customizes NX on this workstation, before a release upgrade.
# Run once per workstation type; compare the reports of old and new installation.
$NxRoot = $env:UGII_BASE_DIR        # or the path of the release you want to inspect
$Report = "C:\nx-upgrade\inventory_$($env:COMPUTERNAME).txt"
New-Item -ItemType Directory -Force -Path (Split-Path $Report) | Out-Null

"== Environment variables (Windows) ==" | Out-File $Report
Get-ChildItem Env: | Where-Object { $_.Name -match '^(UGII_|SPLM_|UGS_)' } | Sort-Object Name |
    ForEach-Object { "$($_.Name) = $($_.Value)" } | Out-File $Report -Append

"== Environment as NX sees it (env_print -all) ==" | Out-File $Report -Append
$envPrint = Get-ChildItem -Path $NxRoot -Filter env_print.exe -Recurse -Depth 2 -ErrorAction SilentlyContinue | Select-Object -First 1
if ($envPrint) { & $envPrint.FullName -all | Out-File $Report -Append }

"== Customer defaults files ==" | Out-File $Report -Append
foreach ($var in "UGII_SITE_DIR", "UGII_GROUP_DIR") {
    $dir = [Environment]::GetEnvironmentVariable($var)
    if ($dir) {
        Get-ChildItem -Path (Join-Path $dir "startup") -Filter *.dpv -ErrorAction SilentlyContinue |
            ForEach-Object { "$var  $($_.FullName)  $($_.LastWriteTime)" } | Out-File $Report -Append
    }
}

"== Custom directories and what they load ==" | Out-File $Report -Append
$dat = if ($env:UGII_CUSTOM_DIRECTORY_FILE) { $env:UGII_CUSTOM_DIRECTORY_FILE } else { Join-Path $NxRoot "ugii\menus\custom_dirs.dat" }
$expand = [System.Text.RegularExpressions.MatchEvaluator] { param($m) [Environment]::GetEnvironmentVariable($m.Groups[1].Value) }
Get-Content $dat -ErrorAction SilentlyContinue | Where-Object { $_.Trim() -and -not $_.TrimStart().StartsWith("#") } | ForEach-Object {
    $root = [regex]::Replace($_.Trim(), '\$\{(\w+)\}', $expand)
    foreach ($sub in "startup", "application", "udo", "udf", "dfa") {
        Get-ChildItem -Path (Join-Path $root $sub) -File -ErrorAction SilentlyContinue |
            ForEach-Object { "$sub  $($_.FullName)  $($_.LastWriteTime)" } | Out-File $Report -Append
    }
}

Lines in the report without an owner are the ones to question first: a customization nobody can explain is a candidate for retirement, not for migration.

Testing NXOpen Programs and Journals

Compiled NXOpen tools have to be recompiled and relinked when you move to a new functional release family, and signed again with the new release’s signing utility. Journals usually run unchanged but still need a test run. Siemens’ “NX Open Differences between releases” pages and the NXOpenReporter toolset tell you upfront what needs rework.

Siemens’ policy helps with planning. NX libraries are forward compatible within a release family, not across families, and the compiler can change with a functional release. A deprecated API stays available in the current and the next release family before it is retired, so reading the change lists gives you one release of warning. NXOpenReporter scans .NET, C++, Python and Java code and writes CSV reports that sort each application into “needs rework”, “future work for deprecation” or “recompile is enough”. Siemens’ comparison pages cover up to two years of releases, one more argument against long upgrade gaps.

For Python journals, check the supported Python version in the release notes of the target release. For Visual Studio projects, regenerate the project files with the NX project wizard of the new release rather than editing old ones. Our guide to migrating NXOpen code across NX releases goes through the code changes in detail.

The second half of the test is behavior. This journal, written with the general NXOpen Python API, opens a folder of reference parts and records body count, feature count and solid volume per part. Run it in the old and the new release and compare the two CSV files; any difference is a part to look at before go-live. It closes every part without saving, so the reference set stays readable for the old release.

# Upgrade regression baseline: run in the old and the new NX release, then compare the CSVs.
# NXOpen Python, general API. Batch example:
#   run_journal.exe upgrade_baseline.py -args C:\nx-upgrade\reference 2606 C:\nx-upgrade\baseline_2606.csv
import csv
import os
import sys

import NXOpen


def measure(part):
    bodies = [b for b in part.Bodies if b.IsSolidBody]
    volume = 0.0
    if bodies:
        units = [part.UnitCollection.GetBase(m) for m in ("Area", "Volume", "Mass", "Length")]
        volume = part.MeasureManager.NewMassProperties(units, 0.99, bodies).Volume
    return len(bodies), len(part.Features.ToArray()), round(volume, 3)


def main(folder, release, out_csv):
    session = NXOpen.Session.GetSession()
    with open(out_csv, "w", newline="") as f:
        writer = csv.writer(f)
        writer.writerow(["release", "part", "unloaded_components", "solid_bodies", "features", "volume"])
        for name in sorted(os.listdir(folder)):
            if not name.lower().endswith(".prt"):
                continue
            part, load_status = session.Parts.Open(os.path.join(folder, name))
            unloaded = load_status.NumberUnloadedParts
            load_status.Dispose()
            writer.writerow([release, name, unloaded] + list(measure(part)))
            # Close without saving: parts saved in a newer release do not open in an older one.
            part.Close(NXOpen.BasePart.CloseWholeTree.TrueValue,
                       NXOpen.BasePart.CloseModified.CloseModified, None)


if __name__ == "__main__":
    folder, release, out_csv = sys.argv[-3:]  # the three values passed after -args
    main(folder, release, out_csv)

Choose the reference parts deliberately: one per template, the parts your NXOpen tools touch, a few heavy feature histories and legacy parts. Twenty well-chosen parts find more than two hundred random ones.

CAM Postprocessors, Templates and Customer Defaults

These three areas break quietly: the post still writes a program, the template still opens, the defaults still load. Test them against reference results from the old release instead of checking that they start.

Postprocessors. For each machine, post a set of reference operations in the old and the new release and compare the NC files line by line, then dry-run anything that differs. Post Builder deserves a decision of its own: the Post Builder repository of the NX Post Builder project team on GitHub states that development stopped with the 1953 series and lists PB1980 as the final release. Siemens documents a converter add-on in a community tech tip, but a converted post is a new post and needs the same buy-off. CAM setup templates need a look too: with Teamcenter 2606, Siemens imports CAM templates automatically during installation and updates, with item IDs that include the unit system and NX version.

Templates. Create one part, one assembly and one drawing from every template entry in the new release, check that the title block fills from attributes, and confirm that File New lists your entries and not the shipped ones. Keep company templates outside the installation directory, where a new release cannot overwrite them.

Customer defaults. Import the old .dpv files per level with Import Defaults, read the summary, then search Find Default for the new release number to list the defaults that are new or changed. User preferences live in a folder per functional release (UserPreferences.txt under %LOCALAPPDATA%\Siemens\), so check what pilot users find in the new release instead of assuming their settings moved along.

Teamcenter, Add-ons and Licenses

Teamcenter is where an NX upgrade touches other teams. Check the support matrix for your NX and Teamcenter combination in Siemens Support Center before anything else, then test the daily operations (save, check-in, revise, clone, where-used) in a test environment with a copy of production data, not on an empty database.

If Teamcenter is due for an upgrade as well, sequence the two instead of combining them in one weekend. Teamcenter 2606 added blue-green deployment, which keeps production running while the upgraded environment is prepared and makes a separate Teamcenter step easier to schedule.

For add-ons, ask each vendor which NX releases their current version supports, and start every add-on on the pilot workstation with one real task. Siemens states that CAM App Hub apps are compatible with the last four NX CAM releases; partner tools follow their own calendars.

Licenses are the cheapest item to forget. Each functional release needs a license that covers it, so request the updated license file before the pilot, not on go-live morning, and update the Siemens License Server software at the same time.

A new release that runs on one test workstation is a prototype. What’s missing for production: an inventory with owners, recompiled and re-signed NXOpen tools, posts bought off on the machines, defaults and templates migrated, a tested Teamcenter combination, trained users and a rollback plan. We run the whole sequence with your team as an NX release upgrade project, from the first inventory to go-live.

Pilot, Training and Rollout

Run the new release in parallel, with a pilot group from each department, for a few weeks of real work before everyone switches. Train the delta beforehand, roll out with a scripted, logged installation, and keep the old release installed until sign-off.

Parallel operation is built in: a functional release installs into its own directory, and the Siemens NX Launcher can set up a sandbox to validate customizations before they reach the pilot. The one rule for pilots is data. Parts saved in the new release do not open in the older one, because each functional release brings a newer Parasolid version. Pilot users therefore work on copies or on projects that only they touch until the switch.

Training is part of the upgrade. Releases change daily habits: Designcenter 2606, for example, keeps sketch relations explicitly instead of inferring them, and redesigned how users find and switch between more than 140 applications. A half day on exactly those changes, on your own parts, saves weeks of tickets; that is the idea behind our NX update training.

For the rollout, script the installation and log it. Monthly updates can be installed unattended with the command Siemens documents in its installation guide:

rem Unattended NX monthly update within an installed release series (from Siemens' NX installation guide).
setup.exe /s /w /v"/qn /L*v C:\temp\upgrade.log REINSTALL=ALL REINSTALLMODE=vomus"

Our team has packaged NX customizations as MSI installers with scripted, logged installation, including restricted IT environments with a role and rights concept. The lesson holds for every upgrade: deployment is half the job.

Frequently Asked Questions

How long does a Siemens NX release upgrade take?

Installing a Siemens NX functional release takes hours; working through the NX upgrade checklist takes days to weeks, depending on how much is built around NX. A site with standard templates and a few journals can switch within a couple of weeks; a site with compiled NXOpen tools, its own postprocessors and a Teamcenter integration should plan a test phase and a pilot of several weeks.

Can you skip NX releases, for example upgrade from NX 2412 directly to NX 2606?

Yes. Siemens NX does not require you to install every functional release; you install the target release into its own directory and migrate from there. Data from older releases stays readable and customer defaults are imported from the older .dpv files, but the NXOpen change lists to review grow with the gap.

Do NXOpen programs need to be recompiled for a new NX release?

Compiled NXOpen programs need to be recompiled, relinked and signed again when you move to a new functional release family, because NX is not binary compatible across families and the compiler can change. Within one family, they run on the monthly updates unchanged. Python and VB journals are not compiled but still need a test run.

NX monthly update vs functional release: what is the difference?

A Siemens NX functional release is a new release series, published every six months, that installs into its own directory, needs a license that covers it and can change NXOpen and prerequisites. A monthly update fixes errors and adds small enhancements within a series, updates the existing installation, is cumulative and does not change Teamcenter or Active Workspace compatibility, so a short regression test is enough.

How much does a Siemens NX upgrade cost?

With active maintenance or a subscription, new Siemens NX releases are included in what you already pay, so the cost of an upgrade is internal effort: inventory, testing, fixes to NXOpen tools and posts, training and rollout. inteliScience offers a free first call with an NX engineer and a one-week NX Engineering Assessment for €4,900 fixed that includes a review of your NX setup and its upgrade risks.


Next Step

Send us the inventory report of one workstation. In a free 60-minute call, inteliScience’s Siemens NX engineers from Cluj-Napoca go through what it shows, which items carry upgrade risk and what a test plan for your next release would cover, under NDA. Talk to an NX engineer about your next NX upgrade



References

  • Siemens, “Designcenter CAD software” (Continuous Release since 2019, year-month naming since NX 2206, Designcenter 2606): https://www.siemens.com/en-us/technology/nx-cad/ (retrieved 6 October 2026)
  • Siemens Designcenter blog, Jamie Tyler, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 6 October 2026)
  • Siemens Designcenter blog, Jamie Tyler, “What’s New in Designcenter, June 2026, Core Capabilities” (8 July 2026, sketch relations, application access): https://blogs.sw.siemens.com/designcenter/whats-new-in-designcenter-june-2026-core-capabilities/ (retrieved 6 October 2026)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 6 October 2026)
  • Siemens, “Designcenter bundles and deployment options” (data from releases back to about 1984 without translation): https://www.siemens.com/en-us/products/designcenter/cad-software/offerings/deployment-licensing-types/ (retrieved 6 October 2026)
  • Siemens Digital Industries Software, General Maintenance Services Terms for Software and Hardware, version 1.5 (December 2025): https://static.sw.cdn.siemens.com/siemens-disw-assets/public/3k6JIlWGIGFemXrJHQtSSP/en-US/GEN%20MNT%20V1.5%202025.12.12%20EN.pdf (retrieved 6 October 2026)
  • Siemens Teamcenter blog, Bill Lewis, “Introducing Teamcenter 2606” (12 June 2026, blue-green deployment): https://blogs.sw.siemens.com/teamcenter/teamcenter-2606/ (retrieved 6 October 2026)
  • Siemens NX Manufacturing blog, Ashley Eckhoff, “What’s new in NX for Manufacturing 2606 (June 2026)” (19 June 2026, automated CAM template import with Teamcenter 2606): https://blogs.sw.siemens.com/nx-manufacturing/whats-new-in-nx-for-manufacturing-2606-june-2026/ (retrieved 6 October 2026)
  • NX Post Builder project team on GitHub, Post Builder repository (development stopped with the 1953 series, PB1980 final release): https://github.com/Unigraphics/PostBuilder (retrieved 6 October 2026)
  • Siemens Community tech tip, “Convert Post Builder postprocessor to Post Configurator”: https://community.sw.siemens.com/s/article/Convert-Post-Builder-postprocessor-to-Post-Configurator (retrieved 6 October 2026)
  • Siemens Support Center knowledge base, “Can a part from a Functional Release of NX be opened in a Monthly Update release?” (PL8792716, login required): https://support.sw.siemens.com/en-US/okba/PL8792716/Can-a-part-from-a-Functional-Release-of-NX-be-opened-in-a-Monthly-Update-release/index.html (retrieved 6 October 2026)
  • Siemens NX 2506 Installation Guide for Windows (functional releases and monthly updates, parallel installation, unattended upgrade command, operating system and runtime requirements), NX Continuous Release documentation, NX Open Programmer’s Guide (release upgrade policy, deprecation, NXOpenReporter, signing) and MenuScript User’s Guide (custom_dirs.dat), checked against the NX 2506 documentation set

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.