NX Templates: Set Up Start Parts Once, Version Them (2026)

NX Templates: The Short Version

NX templates are the start parts that File New copies for every new part, assembly and drawing, with units, attributes, layer categories, reference sets, drawing borders and PMI settings. inteliScience, a Siemens NX specialist delivering nearshore from Romania, sets them up as one versioned set per part type. Result: part one hundred starts like part one, version-stamped.

Start file What it should carry What stays out
Part templateUnits, datum coordinate system, company attributes including a template version, layer categories and work layer, a MODEL reference set, the company drafting and PMI standardGeometry, part numbers, project-specific expressions
Assembly templateThe same units, attributes and categories as the part template, plus the attributes the BOM needsComponents, load options
Drawing templateOne border per sheet size, a title block that reads attributes, the company drafting standard, the master model referenceTyped title block values, notes that belong in the model
Customer defaults (not a template, rolled out with it)How NX behaves and what commands propose, locked at site levelAnything a new part must carry with it

The Problem: Every Designer Starts From a Different Part

Most NX teams do not have a template problem they can see. They have parts that disagree: inch next to millimeter, attributes filled in at release, sketches on layer 1, a reference set called BODY in one part and MODEL in the next. The cause is usually the start: a copied project part instead of a maintained template.

The mechanism is simple. File New copies the template into a new file, and from that moment the new part has no link back to it. Fix the template today and every part created last year still carries yesterday’s settings. Copy an old project part as a “start part” and you inherit its layers, its stale attributes and sometimes its expressions and hidden geometry.

Each deviation costs little on its own. It shows up downstream: the title block that cannot fill itself, the BOM export that misses a material, the assembly that loads the wrong reference set, the checker who sends the drawing back. It also shows up as questions. In a work-sampling study, 78 design engineers logged their current task once an hour for 20 working days, and acquiring and providing information added up to 55.75% of their working time (Robinson, 2010). “Which template, which layer, which attribute?” is exactly that kind of time, asked again by every new designer.

Siemens positions templates as a standardization tool in its own right. Product templates from the reuse library can carry PMI, drawings, motion analysis, structural simulation and validation checking, so that engineering processes are automated and standardized from the start (Siemens, Reuse of CAD data). The tooling is there. What is usually missing is a decision about what goes into the template and a way to keep it current across a team.

What Belongs in NX Templates for Parts, Assemblies and Drawings

A good NX template carries everything that must be identical on every new file and nothing that differs per part. That is a short list: units, attributes, layers and categories, reference sets, the drafting and PMI standard, plus borders and title block for drawings. How the part is then built belongs in your company CAD modeling guidelines, not in the template.

Part template: units, attributes, layers and reference sets

Start with units. A part’s units are set when it is created, and changing them afterward is a conversion job, not a preference. NX ships separate millimeter and inch templates; for a DACH team that means millimeters only, and the inch entries leave the picker unless a customer requires them.

Attributes are the part’s data interface. Define them in the template, present but empty, with the exact titles that your title block, BOM export and Teamcenter mapping expect: description, material, designer, project, and a TEMPLATE_VERSION that the template sets itself. An attribute that exists from the first save gets filled when the designer knows the answer, not when the checker asks.

NX parts have 256 layers. Without a plan, everything lands on layer 1. With one, a designer hides all sketches in one click, the drawing shows only solids and an export can leave construction geometry behind. Name the ranges as layer categories in the template and set the work layer for solids. One common scheme:

Layers Category Contents
1-20SOLIDSFinal solid bodies
21-40SKETCHESSketches
41-60CURVESConstruction curves and points
61-80DATUMSDatum planes, axes and coordinate systems
81-100SHEETSSheet bodies and surfaces
101-256(reserved)Routing, simulation, imported data, later needs

This is not a Siemens standard. Which ranges you choose matters far less than having one that every template shares.

Reference sets decide what an assembly sees of a part. Put a MODEL reference set into the template (the name most NX sites use for the solid body set) and check the assembly customer defaults that control whether new solid bodies are added to it automatically. Keep the datum coordinate system that the shipped model template has at the absolute origin.

Our clear recommendation: no geometry, no part number and no project expressions in a part template. Each of them is copied into thousands of parts and is wrong for most of them.

Assembly template: the same base, a different job

An assembly template shares units, attributes and layer categories with the part template, so a subassembly does not quietly switch conventions. Add the attributes your BOM needs at assembly level. Leave load behavior out: which reference set NX tries first when it loads a component, for example MODEL before Entire Part, is set in the assembly load options and their customer defaults, not in the file.

Drawing template: borders, title block and drafting standard

Drawing templates need the most care and usually get the least. Build one border per sheet size you actually use, A0 to A4 for most DACH companies, with the Borders and Zones command, and turn the title block table into a defined title block with Define Title Block (Swoosh Technologies).

Every field that exists as an attribute should reference it: part number, description, material, revision, drawn by. A typed title block is wrong after the next revision.

The drafting standard is part of the template as well. For DACH that means ISO with first-angle projection, saved as a named company standard at site level, so dimension styles, fonts and arrowheads match on every sheet. In the template’s PAX entry, the UsesMasterModel setting makes a new drawing ask for the model it documents instead of standing alone. You want that on every drawing template.

Two of our engineers have each built drawing derivation for part families in earlier positions: one template drawing, then a drawing for every family member. Both projects started with the same step, cleaning up the template drawing, because automation repeats its errors on every member.

PMI settings and model views

If you author PMI, or plan to, the part template is where your MBD standard becomes the default. Set the PMI preferences to the same company drafting standard as the drawings, create the named model views your standard prescribes and add the attributes a supplier data package needs. A PMI setup that differs from the drawing template produces two annotation styles on one part.

NX Templates vs Customer Defaults: Which Setting Lives Where

A setting belongs in the template if every new file must carry it and keep it. It belongs in customer defaults if it controls how NX behaves or what a command proposes. Templates travel with the part. Customer defaults stay with the installation, in .dpv files on three levels (site, group and user), where an administrator can lock values.

Setting In the template part In customer defaults Reason
UnitsYes, one template per unit systemWhich template File New offers firstFixed when the part is created
Attributes (titles, empty values)YesNoEvery part must have them
Layer categories and work layerYesNoStored in the part
MODEL reference setYes, the set itselfAutomatic body assignment, load orderName in the part, behavior in the defaults
Drafting and PMI standardSaved preferencesThe named company standard at site levelBoth must match
Assembly load optionsNoYesSession behavior
Material library locationNoYesA site file, not part data

Site and group defaults are stored as nx_site.dpv and nx_group.dpv in a startup subfolder of the directories that UGII_SITE_DIR and UGII_GROUP_DIR point to; user defaults go to the file named by UGII_LOCAL_USER_DEFAULTS (Swoosh Technologies). Lock at site level whatever your templates rely on. We’d advise against leaving units or the default template to the user level: one changed user default, and a designer builds inch parts for a month before anyone notices.

Some rules fit neither place, such as “no sketch on the solid layer” or “material must come from the approved list”. Those are checks, and our guide to checking company design rules in Siemens NX shows how a written rule becomes an executable one.

How to Build and Register an NX Template

Build a template like a deliverable: from a clean copy of the shipped Siemens template, with every setting taken from a written spec, registered in a PAX file and tested through File New on a second workstation. For drawing templates, the Mark as Template command in Drafting does the registration for you.

  1. Write the spec first. One page per template type: units, attribute titles, layer plan, reference sets, drafting standard, sheet sizes. The spec is what your methods team reviews, not the part file.
  2. Start from the shipped template of the right type and units, never from a project part. Project parts carry history nobody can see.
  3. Apply the spec. Attributes (empty, except TEMPLATE_VERSION), layer categories and work layer, reference sets, preferences. For drawings: borders, attribute-driven title block, drafting standard.
  4. Register it in a PAX file. The PAX file is the XML file that defines what File New lists, with a name, a description, the units and the template file. For drawing templates, Mark as Template in Drafting writes the entry; part and assembly entries are edited into the PAX file. Drawing templates go into ugs_drawing_templates.pax, sheet templates into ugs_sheet_templates.pax; Teamcenter-managed installations use the nxdm_ variants.
  5. Test on a clean workstation. Create one part, one assembly and one drawing from the new entries, run the audit journal below on them and check that the title block fills from attributes.
  6. Release it. New version number, a short change note, into the release folder.

Keep the File New dialog short. Strip the PAX files down to the templates your company uses, one per type, unit system and sheet size. A picker with thirty entries, half of them inch and ANSI, is how a third-angle drawing ends up at a European supplier.

Rolling Out and Versioning NX Templates Across a Team

Treat the template set like software: one source under version control, numbered releases, a deployment that puts the same release on every workstation, and a version stamp inside every part. Without the stamp you cannot tell which parts need attention after a template change, because NX never updates existing parts.

One release folder outside the NX installation

Keep templates, PAX files and site customer defaults in a company folder, not in the NX installation directory, where the next upgrade replaces them. Point NX at that folder with the UGII_TEMPLATE_DIR environment variable, check in File New that only your entries appear, and keep the source in Git or a controlled share with a changelog. Deployment then mirrors one release to every workstation and logs it:

# Deploy one released NX template set to a workstation.
# Run from your software deployment tool with administrator rights.
$Release = "2026.10"
$Source  = "\\cadfs01\nx-standards\templates\releases\$Release"
$Target  = "D:\NX_Site\templates"
$Log     = "D:\NX_Site\logs\template-deploy.log"

# Mirror the release: the same PAX files and template parts on every seat, nothing else.
robocopy $Source $Target /MIR /R:2 /W:5 /NP /LOG+:$Log
if ($LASTEXITCODE -ge 8) { throw "Template deployment $Release failed, see $Log" }

# Record the installed release, then point NX at the company folder.
Set-Content -Path (Join-Path $Target "TEMPLATE_RELEASE.txt") -Value $Release
[Environment]::SetEnvironmentVariable("UGII_TEMPLATE_DIR", "$Target\", "Machine")

Our team has done this before, in earlier positions at an international commercial-vehicle manufacturer: attribute and naming standards for the NX and Teamcenter integration, NX customizations packaged as MSI installers with scripted, logged installation, and operation in a restricted IT environment with a role and rights concept. The lesson we took from it: deployment is half the work. A template that sits on the share but not on every seat is not a standard.

A version number inside every part

Because File New copies the template, the TEMPLATE_VERSION attribute is the only reliable way to know later which settings a part started with. Use a date-based number such as 2026.10 and change it with every release. When the drafting standard changes, you can then list exactly the parts that predate it, instead of guessing from creation dates.

Audit the parts that already exist

The journal below uses the general NXOpen Python API to compare a folder of parts with the template spec: units, required attributes, layer categories, reference sets and template version. Run it on a sample of recent parts before the rollout to see where you stand, and again a month later to see whether new parts start right.

# NX template audit: does each part match the template spec,
# and which template version did it start from?
# NXOpen Python, general API. Batch example:
#   run_journal template_audit.py -args C:\nx-audit\parts C:\nx-audit\template_audit.csv
import csv
import os
import sys

import NXOpen

# Template spec (example values; take yours from the written spec).
CURRENT_VERSION = "2026.10"
EXPECTED_UNITS = NXOpen.BasePart.Units.Millimeters
REQUIRED_ATTRIBUTES = ["DESCRIPTION", "MATERIAL", "DESIGNER", "TEMPLATE_VERSION"]
REQUIRED_CATEGORIES = {"SOLIDS", "SKETCHES", "CURVES", "DATUMS", "SHEETS"}
REQUIRED_REFERENCE_SETS = {"MODEL"}
STRING = NXOpen.NXObject.AttributeType.String


def has_attribute(part, title):
    return part.HasUserAttribute(title, STRING, -1)


def audit(part):
    version = part.GetUserAttributeAsString("TEMPLATE_VERSION", STRING, -1) \
        if has_attribute(part, "TEMPLATE_VERSION") else ""
    categories = {c.Name.upper() for c in part.LayerCategories}
    reference_sets = {r.Name.upper() for r in part.GetAllReferenceSets()}
    return [
        "ok" if part.PartUnits == EXPECTED_UNITS else "wrong units",
        version or "none",
        "current" if version == CURRENT_VERSION else "outdated",
        ";".join(a for a in REQUIRED_ATTRIBUTES if not has_attribute(part, a)),
        ";".join(sorted(REQUIRED_CATEGORIES - categories)),
        ";".join(sorted(REQUIRED_REFERENCE_SETS - reference_sets)),
    ]


def main(folder, out_csv):
    session = NXOpen.Session.GetSession()
    with open(out_csv, "w", newline="") as f:
        writer = csv.writer(f)
        writer.writerow(["part", "units", "template_version", "status", "missing_attributes",
                         "missing_categories", "missing_reference_sets"])
        for name in sorted(os.listdir(folder)):
            if not name.lower().endswith(".prt"):
                continue
            part, load_status = session.Parts.Open(os.path.join(folder, name))
            load_status.Dispose()
            writer.writerow([name] + audit(part))
            part.Close(NXOpen.BasePart.CloseWholeTree.TrueValue,
                       NXOpen.BasePart.CloseModified.CloseModified, None)


if __name__ == "__main__":
    folder, out_csv = sys.argv[-2:]  # the two values passed after -args
    main(folder, out_csv)

For Teamcenter-managed data, export a sample to a native folder first or adapt the open call. Deviations that keep coming back belong in Check-Mate, where designers see them while they work; our guide to writing custom Check-Mate checkers for company rules covers that step.

Test against every NX release

Siemens ships two releases a year. The June 2026 release (Designcenter 2606, announced on 23 June 2026) also renamed Designcenter NX to Designcenter, and the early access program for Designcenter 2612 ran from 31 August to 25 September 2026.

Before each upgrade, create one file from every template in the new version, run the audit and check a drawing title block. The shipped templates and PAX files in the installation folder change with the release. Yours should not.

One clean template set on one workstation is a prototype. What’s missing for production: a written spec your methods team owns, the same release on every seat and in Teamcenter, locked site defaults, an audit of the parts already out there, and designers trained on the new standard. We set this up with your team, tested on your own parts, as part of engineering process optimization for Siemens NX.

NX Templates in Teamcenter

In a Teamcenter-managed environment the templates themselves live in Teamcenter, and the Teamcenter-managed PAX files (the nxdm_ variants) point File New at them. That makes versioning easier, not harder: a template revision with a release status replaces the copied folder, and only released revisions should appear in the picker.

Item types, IDs and attribute mappings

In the Teamcenter-managed PAX entries, each template also names the item type a new part is created as. Point your templates at your company’s item types, so that naming rules assign the ID and the right properties and workflows apply from the first save. A part number never belongs in a template.

Title block attributes should come from Teamcenter rather than be typed in NX. Attribute mappings connect NX part attributes to Teamcenter properties (administrators maintain them with the import_attr_mappings utility), so a description entered once in Teamcenter appears in the part and on the drawing. Decide per attribute which side is the master, and write it into the template spec. What has to work before any of this, from the first save and check-in onward, is in our guide to setting up the Teamcenter NX integration.

Templates and the reuse library follow one rule

Our team has also developed, in earlier positions, a library for recurring design elements to company standards: standard parts, features, approved assemblies and templates, inserted into NX and Teamcenter with the correct attributes, names and metadata. Templates and library share one rule. Whatever a designer starts from or drops into an assembly must already conform, because nobody fixes conformity later at scale.

Frequently Asked Questions

How do you create a custom part template in Siemens NX?

Create a new part from the shipped template with the right units, apply your company settings (attributes, layer categories, reference sets, drafting and PMI preferences), save it and add an entry for it to a PAX file so the template appears in File New (for drawing templates, the Mark as Template command in Drafting writes that entry). Keep the template and its PAX file in a company folder referenced by UGII_TEMPLATE_DIR rather than in the NX installation, so an upgrade does not overwrite them. Test it on a second workstation before you release it.

NX templates vs customer defaults: what is the difference?

NX templates are part files that File New copies, so their settings (units, attributes, layers, reference sets, saved preferences) travel with every new part. Customer defaults are the initial values and behavior settings of NX itself, stored in .dpv files at site, group and user level, and they stay with the installation. Use templates for what every part must carry, and customer defaults, locked at site level, for how NX behaves.

Does changing an NX template update parts already created from it?

No. NX copies the template when a part is created and keeps no link to it, so a template change only affects parts created afterward. Existing parts have to be found and corrected separately, which is why we put a template version attribute into every template and audit parts in batch with NXOpen to list the ones created from older versions.

How do NX templates work with Teamcenter?

In Teamcenter-managed NX, the templates are stored in Teamcenter and listed through Teamcenter-specific PAX files (the nxdm_ variants), and each template also sets the item type a new part is created as. Template versions then follow Teamcenter revisions and release status instead of folder copies. Title block attributes should be mapped to Teamcenter properties, so they are maintained once and not typed in NX.

How much does it cost to set up NX templates for a design team?

There is no list price, because the effort depends on the number of template types, unit systems, drafting standards and sheet sizes, and on how many existing parts must be audited. Most of it is internal methods and CAD admin time for the spec, testing and rollout; the template files themselves take days, not months. inteliScience offers a free first call with an NX engineer and a one-week NX Engineering Assessment for €4,900 fixed that scores templates together with the rest of the NX design process.


Next Step

Bring one part, one assembly and one drawing your team created last month. In a free 60-minute call, inteliScience’s Siemens NX engineers from Cluj-Napoca look at what your templates carry today, where new parts drift from them and what a versioned template set would change, under NDA. Talk to an NX engineer about your template set



References

  • Robinson, M. A., “An empirical analysis of engineers’ information behaviors”, Journal of the American Society for Information Science and Technology 61(4), 640-658, 2010: https://doi.org/10.1002/asi.21290 (metadata and abstract retrieved via Crossref, 9 October 2026)
  • Siemens, “Reuse of CAD data” (Designcenter NX reuse library and product templates): https://www.siemens.com/en-us/products/designcenter/nx-cad-software/mcad/reuse-cad-data/ (retrieved 9 October 2026)
  • Siemens, “CAD model design validation” (Check-Mate): https://www.siemens.com/en-us/products/designcenter/nx-cad-software/mcad/design-validation/ (retrieved 9 October 2026)
  • Swoosh Technologies, “How to create a custom drafting template in NX” (23 September 2022): https://www.swooshtech.com/2022/09/23/how-to-create-a-custom-drafting-template-in-nx/ (retrieved 9 October 2026)
  • Swoosh Technologies, “How to define the defaults level of Customer Defaults” (6 April 2023): https://www.swooshtech.com/2023/04/06/how-to-define-the-defaults-level-of-customer-defaults/ (retrieved 9 October 2026)
  • Siemens Designcenter blog, Jamie Tyler, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 9 October 2026)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612): https://resources.sw.siemens.com/pl-PL/presentation-welcome-to-designcenter-early-access-program/ (retrieved 9 October 2026)
  • NXOpen .NET reference (NX 2022.1 mirror): BasePart (PartUnits, LayerCategories, GetAllReferenceSets), NXObject (HasUserAttribute, GetUserAttributeAsString): https://nxopencsdocumentation.thescriptingengineer.com/NX2022_1/NXOpen.BasePart.html (retrieved 9 October 2026)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.