NX STEP Import: Settings, Checks and a Supplier Agreement

NX STEP Import: The Short Version

NX STEP import is reliable when the settings are fixed: import solids and surfaces, sew automatically, keep the assembly structure, and leave Simplify and Optimize off on the first pass. inteliScience’s NX design engineers add post-import checks and a one-page supplier agreement on AP242, units and validation properties, so fewer surface models reach your assemblies.


The Problem: Surface Models and Flat Assemblies From Non-NX Suppliers

A supplier models in CATIA, SolidWorks or Creo, sends a STEP file, and someone drops it into your NX assembly. Weeks later the bracket turns out to be a set of sheet bodies on layer 1, the purchased gearbox is one flat part instead of an assembly, and nobody knows which import settings were used.

STEP is the neutral format of ISO 10303, and it carries shape, not design intent. Whether that shape arrives in NX as a clean solid depends on three things: what the supplier exported, which protocol they used, and how the file was imported. Two of the three you can control, and the third you can put in writing.

Symptom after the NX STEP import Likely cause Where to fix it
Sheet bodies instead of a solidSurface model exported, or faces that do not meet within toleranceImport options (sew), then sew or heal in NX; supplier export
One flat part instead of componentsFlatten Assembly switched on, or a single-product exportImport options; supplier export
Size off by a factor of 25.4Inch and millimetre mixed up in the exportPre-check of the file; units in the agreement
Objects on unexpected layersSTEP layer 0 mapped to NX layer 1; STEP layers above 256 wrap aroundLayer setting on import; your layer standard
PMI visible but not editableAP242 PMI arrives as Imported PMIConvert PMI where you need to edit
Components missing in the navigatorHidden in the source, and NX keeps that state on importShow hidden objects, compare with the BOM

Each sheet body and each heavy, history-free body that stays in an assembly costs load time and graphics performance across every session that opens it. What that does to big structures, and how to find the worst offenders, is the subject of our guide to NX large assembly performance.


AP203 vs AP214 vs AP242: Which STEP Protocol to Accept

Ask for AP242. Of the three, it is the only protocol that carries PMI semantically, and the CAx Interoperability Forum (CAx-IF) puts it plainly: “Semantic Representation of PMI data as described in this document is supported by AP242 only” (CAx-IF, June 2024). AP214 remains a solid choice for geometry without PMI.

Protocol Editions (schema year, CAx-IF) What it carries for NX users Our verdict for supplier files
AP203Edition 1; Edition 2 (2011)Geometry and assembly structure; Edition 2 adds presentation such as colors and graphic PMIAccept for plain geometry, reject Edition 1 for anything with PMI
AP214Edition 3 (2010)Geometry, assembly structure, colors, layers, graphic PMIGood fallback when AP242 is not available
AP242Edition 1 (2014), 2 (2019), 3 (2022), 4 (2025)Everything above plus semantic PMI and tessellated geometryDefault request

The edition years come from the schema annex of the CAx-IF practices for model styling and organization (CAx-IF, version 1.10). The protocol is named in the file header as the FILE_SCHEMA: AP242_MANAGED_MODEL_BASED_3D_ENGINEERING_MIM_LF for AP242, AUTOMOTIVE_DESIGN for AP214, CONFIG_CONTROL_DESIGN for the first edition of AP203 (ISO 10303-21 text, STEP Tools). You can read it before NX ever sees the file, as the working example below shows.

Our clear recommendation: request AP242 in the newest edition both CAD systems export, accept AP214 for geometry-only parts, and treat an AP203 first edition file as a legacy format that tells you the supplier’s export settings deserve a conversation.


NX STEP Import Options That Decide Solid or Surface

In NX, STEP import sits under File > Import. Siemens partner Swoosh Technologies documented one entry per protocol for NX 12, STEP203, STEP214 and STEP242 (Swoosh Technologies), and the NXOpen API mirrors that with Step203Importer, Step214Importer and Step242Importer (NXOpen reference, NX 1926). NX can also open a STEP242 file directly. Dialog labels can differ between releases; the option set behind them has stayed the same in the API from the NX 6 importers to the NX 1926 reference (checked October 2026), which is why the table names the API property too.

Option (NX Help label) NXOpen property Default Our setting for supplier files Why
Import toImportToWork partNew part for anything you keep; work part only for a scratch inspectionA supplier part should be its own NX part, not bodies merged into yours
Model Data (object types)ObjectTypesSolids onlySolids, surfaces and PMI; curves only on requestA surface model should show up as sheets, not vanish in a filter
Sew Surfaces AutomaticallySewSurfacesOffOnCloses sheets into solids where edges meet
SimplifySimplifyGeometryOffOff on the first importRewrites the geometry you received
OptimizeOptimizeOffOff on the first importSame reason
Smooth B-SurfacesSmoothBSurfacesOnOnRemoves knots whose multiplicity equals the surface degree (non-rational B-surfaces)
Flatten AssemblyFlattenAssemblyOffOffOn puts all STEP products into one NX part
Layer Default for Level 0LayerDefault (203 and 214 importers)NX layer 1Your import layerSTEP layers above 256 wrap around
Settings FileSettingsFileTranslator defaultOne saved file per supplier classSame file, same result

Sources for labels and behavior: Siemens NX Help, “Import from STEP options dialog box” (archived copy of an earlier release); defaults for the API from the Step242Importer reference.

Three of these settings deserve a sentence more.

Sew Surfaces Automatically starts after the data is in NX. According to Siemens’ help, the translator cycles through the sewing at a fixed tolerance of 0.1 mm, drops problem surfaces at each stage, makes five attempts, and leaves surfaces that would create non-manifold conditions out of the sewn solid. That is enough for clean surface models and not enough for a sloppy one, which is why you check the result instead of trusting the switch.

Simplify and Optimize change the geometry on the way in. We’d advise against them on the first import of a supplier file: you want to see the data as delivered, judge it, and then decide whether a second import with those options is worth it.

Layer Default for Level 0 maps STEP layer 0 to an NX layer, and STEP layers 257 to 512 land on NX layers 1 to 256 again. If your layer standard reserves layers for imported geometry, set it here, not after the fact.

PMI from AP242 files arrives as Imported PMI, which Siemens describes as graphically accurate and semantically rich; the Convert PMI command, introduced with NX 2206 in June 2022, turns it into native PMI you can edit (Siemens, AP242 update, October 2022). The same Siemens update notes that step242ug.def accepts a metric and an inch template part (BASE_PART_MM, BASE_PART_IN), so a STEP242 file imported to a new part starts with your company preferences.


Working Example: Check the File, Then Run an Inspection Import

A good NX STEP import starts before NX: read the file, know what is inside, then import it once under controlled settings and count what arrived. Two short scripts do that.

Step 1: Read the STEP file before NX does

A STEP file is plain text (ISO 10303-21). This script needs only Python 3 and reports the protocol, the length unit, how many solids and surface models the file contains, the number of assembly usages, and whether the supplier wrote validation properties. We tested it on public sample assemblies in AP203 and AP214 and on a hand-written AP242 header.

# step_precheck.py: look inside a supplier STEP file before it goes into NX.
# Plain Python 3, no NX needed.  Usage: python step_precheck.py bracket.stp
import re
import sys
from pathlib import Path

SCHEMAS = {
    "AP242_MANAGED_MODEL_BASED_3D_ENGINEERING_MIM_LF": "AP242",
    "AUTOMOTIVE_DESIGN": "AP214",
    "AP203_CONFIGURATION_CONTROLLED_3D_DESIGN_OF_MECHANICAL_PARTS_AND_ASSEMBLIES_MIM_LF": "AP203 ed. 2",
    "CONFIG_CONTROL_DESIGN": "AP203 ed. 1",
}

data = Path(sys.argv[1]).read_text(encoding="latin-1").upper()

def count(entity):
    # simple instances such as  #20=MANIFOLD_SOLID_BREP('',#21);
    return len(re.findall(r"=\s*" + entity + r"\s*\(", data))

schema = re.search(r"FILE_SCHEMA\s*\(\s*\(\s*'([A-Z0-9_]+)", data)
schema = schema.group(1) if schema else "not found"
print("protocol      :", SCHEMAS.get(schema, schema))

# an inch definition anywhere wins; mixed-unit files deserve a closer look
if re.search(r"CONVERSION_BASED_UNIT\s*\(\s*'INCH'", data):
    unit = "inch"
else:
    si = re.search(r"SI_UNIT\s*\(\s*(\.[A-Z]+\.|\$)\s*,\s*\.METRE\.", data)
    unit = {".MILLI.": "mm", ".CENTI.": "cm", "$": "m"}.get(si.group(1), si.group(1)) if si else "unknown"
print("length unit   :", unit)

solids = count("MANIFOLD_SOLID_BREP") + count("BREP_WITH_VOIDS")
surface_models = count("SHELL_BASED_SURFACE_MODEL")
print("solid bodies  :", solids)
print("surface models:", surface_models, " <- expect sheets in NX" if surface_models else "")
print("assembly uses :", count("NEXT_ASSEMBLY_USAGE_OCCURRENCE"))
print("validation    :", "geometric" if "'GEOMETRIC VALIDATION PROPERTY'" in data else "none",
      "+ assembly" if "'ASSEMBLY VALIDATION PROPERTY'" in data else "")

The entity names are standard STEP entities (the CAx-IF lists MANIFOLD_SOLID_BREP, BREP_WITH_VOIDS and SHELL_BASED_SURFACE_MODEL among the geometric items that carry validation properties), and the two property labels are the CAx-IF’s agreed strings (CAx-IF validation properties, version 4.6). A file that reports surface models and no solids depends entirely on the sew step in NX; decide before it enters an assembly whether you sew, send it back or plan a repair.

Step 2: Import with fixed settings and count solids and sheets

The second script is an NX journal in Python. Run it in an empty scratch part in native mode. It imports one AP242 file with the settings from the table, flattens the assembly on purpose so that every body lands in the work part and can be counted, and lists what stayed a sheet. Your production import keeps the structure.

# NX journal (Python): inspection import of one supplier STEP AP242 file.
# Run in an empty scratch part (native mode). The assembly is flattened on purpose
# so every imported body can be counted; production imports keep the structure.
# For AP214 or AP203 files use CreateStep214Importer / CreateStep203Importer.
import NXOpen

STEP_FILE = r"C:\exchange\incoming\supplier_bracket.stp"   # adjust

session = NXOpen.Session.GetSession()
work_part = session.Parts.Work
lw = session.ListingWindow
lw.Open()

before = {body.Tag for body in work_part.Bodies}

importer = session.DexManager.CreateStep242Importer()
try:
    importer.InputFile = STEP_FILE
    importer.OutputFile = work_part.FullPath
    importer.FileOpenFlag = False                    # file import, not File > Open
    importer.ImportTo = NXOpen.Step242Importer.ImportToOption.WorkPart
    importer.FlattenAssembly = True                  # inspection only
    importer.ObjectTypes.Solids = True
    importer.ObjectTypes.Surfaces = True             # let surface models show up
    importer.ObjectTypes.Curves = False
    importer.ObjectTypes.PmiData = True
    importer.SewSurfaces = True
    importer.SimplifyGeometry = False                # see the data as delivered
    importer.Optimize = False
    importer.ProcessHoldFlag = True                  # wait for the translator
    lw.WriteLine(f"settings file: {importer.SettingsFile}")
    importer.Commit()
finally:
    importer.Destroy()

new_bodies = [b for b in work_part.Bodies if b.Tag not in before]
solids = [b for b in new_bodies if b.IsSolidBody]
sheets = [b for b in new_bodies if b.IsSheetBody]
lw.WriteLine(f"imported bodies: {len(new_bodies)}  solids: {len(solids)}  sheets: {len(sheets)}")
for b in sheets:
    lw.WriteLine(f"  sheet body on layer {b.Layer}: {b.JournalIdentifier}")

The members used are documented in Siemens’ NXOpen reference: the importer and its defaults (Step242Importer, created in NX 11), the object type switches (ObjectTypeSelector) and the body queries (Body). Store the settings you settle on with Save Settings (SaveSettings in the API), and the next import of the same supplier behaves the same way.


What to Check Right After the NX STEP Import

Six checks catch nearly everything the table at the top describes, and none needs more than NX itself. Run them on every new supplier and on every first revision of a part that goes into a released assembly.

  1. Body type. Every part should be one solid. If sheets remain, sew them with a tolerance that matches the gaps, heal, or send the file back; the options for converting surfaces to a solid in NX have their own guide.
  2. Geometry health. Examine Geometry (Analysis tab) checks, among other things, for tiny bodies, faces, edges and curves (Applied CAx).
  3. Mass properties against the supplier’s values. If the pre-check found geometric validation properties, the sending system wrote volume, surface area and centroid into the file. Compare them with Measure in NX. The CAx-IF quotes proven industry thresholds of 0.5 percent for solid volume and surface area and 0.02 mm plus a 0.1 percent ratio for the centroid of parts larger than 20 mm (version 4.6, April 2023).
  4. Units and size. Measure one dimension you know from the supplier’s drawing. A factor of 25.4 is an inch and millimetre mix-up, and the pre-check would have shown it.
  5. Assembly structure, layers and hidden objects. Compare the component count in the Assembly Navigator with the supplier’s BOM and the assembly usages from the pre-check, look at where the objects landed in Layer Settings, and show hidden objects: Siemens notes that invisibility defined in a STEP file is honored on import.
  6. PMI. If you imported AP242 PMI, check that it sits on the right faces and views, and convert only what you need to edit.

This works for one file on one workstation. What’s missing for production: A settings file per supplier class under version control, the pre-check built into your incoming-data step, an exchange agreement that purchasing actually sends, and engineering capacity for the parts that still arrive as surfaces or heavy, history-free bodies. Our NX design engineers close that gap with STEP file remodeling in Siemens NX: native solids with editable features, checked against the supplier geometry before release.


A One-Page Data Exchange Agreement for Non-NX Suppliers

The cheapest repair is the one you never do. A one-page agreement, attached to the purchase order or the supplier quality manual, moves most fixes upstream to the system that created the geometry and knows its own tolerances.

Item What to ask for Why it matters in NX
ProtocolSTEP AP242 in the newest edition both systems support; AP214 as fallbackSemantic PMI travels in AP242 only
Body typeOne closed solid per part; no loose surfaces, no construction geometrySheets stay sheets in your assembly
UnitsMillimetres, stated in the agreementNo scale surprises
Assembly structureStructure kept; one STEP product per supplier part numberThe Assembly Navigator matches their BOM
Validation propertiesGeometric and assembly validation properties switched on, where the sending system offers themYou can check volume, area and centroid against the CAx-IF thresholds
PMISemantic PMI in AP242 where you use it downstream; otherwise the drawing as PDFImported PMI is read-only until converted
Level of detailFor purchased parts, an envelope with all interfaces (mounting holes, connectors, keep-out zones)Lighter assemblies, faster sessions
Naming and revisionFile name with part number and revisionClean replacement when the next revision arrives

We’d advise against “STEP, any version” in purchase orders. It sounds flexible and guarantees surprises, because each supplier’s default export settings then decide what lands in your NX assemblies.

NX also has direct translators for systems such as CATIA V5, Creo, SolidWorks and Inventor (Siemens). If your licences cover them and a supplier is willing to share native files, test that path once against STEP on the same part. Agree on one route per supplier, not a mix.


When a Part Keeps Arriving Broken: Remodel It Once

Some supplier parts will never import cleanly: surface-only exports from a styling tool, castings with gaps beyond any sensible sew tolerance, or heavy history-free bodies that the whole plant layout drags along. If such a part is used in many assemblies or your own team changes it, repairing it at every revision is the expensive path. Remodel it once as a native NX part.

At inteliScience, that is the work of our NX design engineers, a nearshore team in Romania serving engineering teams in the DACH region: a native NX solid with editable features, built against the imported body. AI and automation speed up the routine part, for example proposing a feature structure from the imported body and comparing the rebuilt model with the source. The engineer models, checks and releases; we do not promise a fully automatic conversion. The comparison uses NX’s own tools: Compare Body marks faces as absent, new or changed between a control and a sample body, and its Deviation option shows how far each face moved (NX Design blog, July 2023). More on the wider discipline is on our page about AI-assisted geometry creation in Siemens NX.

One practical note for anyone writing this into a process: rerun your inspection import after each NX upgrade. The next Designcenter release, 2612, went through Siemens’ Early Access Program from 31 August to 25 September 2026 (Siemens), and translator behavior is exactly the kind of thing worth a quick regression check.


Frequently Asked Questions

Why does a STEP file import into Siemens NX as surfaces instead of a solid?

Because the file contains surfaces rather than a closed solid, or faces that do not meet within tolerance. In the NX STEP import, select Surfaces as well as Solids and switch on Sew Surfaces Automatically; according to Siemens’ help, the translator sews at a fixed 0.1 mm tolerance and leaves out faces that would create non-manifold conditions. Whatever stays a sheet needs a manual sew, healing or a remodel.

AP214 vs AP242: which STEP format should suppliers send for Siemens NX?

AP242, whenever both CAD systems support it. AP214 carries geometry, assembly structure, colors and layers and is fine for geometry without PMI; AP242 adds semantic PMI, which the CAx-IF describes as supported by AP242 only. An AP203 first edition file is a legacy format and a reason to talk to the supplier about export settings.

Does Siemens NX import PMI from STEP files?

Yes, from AP242 files. Siemens describes PMI from STEP242 and JT files as created as Imported PMI in NX, which displays consistently and can be checked with PMI Advisor. Imported PMI cannot be edited until you convert it with the Convert PMI command, available since NX 2206 (June 2022).

Can NX keep the assembly structure of a STEP file on import?

Yes, as long as Flatten Assembly stays off: the translator then imports the STEP products as NX components. With Flatten Assembly on, all products land in one NX part, which suits a quick envelope check and not an assembly you maintain. Compare the component count with the supplier’s BOM after import.

How much effort is it to remodel a supplier STEP part as a native NX part?

It depends on the geometry, not on the file size. A prismatic bracket with holes and blends is a short job for an NX designer, while a casting with drafts and freeform surfaces takes considerably longer, and how often you will change the part decides whether remodeling pays at all. We size it on a small batch of your own files first, with every rebuilt model checked against the supplier geometry.


Next Step

Bring a handful of the supplier STEP files that cause the most trouble. In an NX Sprint on a small batch of your own parts, inteliScience’s NX design engineers run the inspection import, draft the exchange agreement for your suppliers and remodel the parts that need it, so you judge the result in your own assemblies. Talk to our NX engineers about your supplier STEP files



References

  • Siemens NX Help, “Import from STEP options dialog box” (earlier NX release, copy hosted by the University of Rochester, archived 6 February 2023): http://web.archive.org/web/20230206063546/http://www2.me.rochester.edu/courses/ME204/nx_help/en_US/tdocExt/content/9/xid454879.xml (retrieved 2026-10-02)
  • Siemens NXOpen .NET Reference (NX 1926), NXOpen.Step242Importer, NXOpen.ObjectTypeSelector, NXOpen.DexManager: https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a07956.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a06917.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a03519.html (retrieved 2026-10-02)
  • NX Open C++ Reference, NXOpen::Body: https://www.ugapi.com/doc/NXOpen/a00707.html (retrieved 2026-10-02)
  • Siemens Digital Industries Software, “Siemens STEP Support, Update Presentation” (AP242 Day, 20 October 2022): https://www.afnet.fr/Content/2022-AP242DAY/Siemens_vendor_update_October%202022_bd.pdf (retrieved 2026-10-02)
  • Siemens Designcenter blog, “Convert Imported PMI, NX Tips and Tricks” (4 October 2023): https://blogs.sw.siemens.com/designcenter/converting-imported-product-manufacturing-information-within-siemens-nx/ (retrieved 2026-10-02)
  • CAx-IF, “Recommended Practices for the Representation and Presentation of Product Manufacturing Information (PMI) (AP242)”, version 4.1 (20 June 2024): https://www.mbx-if.org/home/wp-content/uploads/2024/06/rec_pracs_pmi_v41.pdf (retrieved 2026-10-02)
  • CAx-IF, “Recommended Practices for Geometric and Assembly Validation Properties”, version 4.6 (21 April 2023): https://www.mbx-if.org/home/wp-content/uploads/2024/05/rec_prac_gvp_v46.pdf (retrieved 2026-10-02)
  • CAx-IF, “Recommended Practices for Model Styling and Organization”, version 1.10: https://www.mbx-if.org/home/wp-content/uploads/2026/08/rec_prac_styling_org_v1.10.pdf (retrieved 2026-10-02)
  • ISO 10303-21, Edition 3, final text (file header and FILE_SCHEMA examples), hosted by STEP Tools: https://www.steptools.com/stds/step/IS_final_p21e3.html (retrieved 2026-10-02)
  • Swoosh Technologies, “Taking the Next STEP in NX” (13 April 2018, NX 12): https://www.swooshtech.com/2018/04/13/taking-the-next-step-in-nx/ (retrieved 2026-10-02)
  • Applied CAx, “Examine Geometry and Heal Geometry, NX CAD Tips and Tricks” (14 July 2017): https://www.appliedcax.com/resources/nx-cad/examine-geometry-heal-geometry-nx-cad-tips-and-tricks/ (retrieved 2026-10-02)
  • Siemens NX Design blog, “Compare Body, NX Tips and Tricks” (7 July 2023): https://blogs.sw.siemens.com/nx-design/compare-body-nx-tips-and-tricks/ (retrieved 2026-10-02)
  • Siemens, “CAD interoperability”: https://www.siemens.com/en-us/products/designcenter/cad-software/cad-interoperability/ (retrieved 2026-10-02)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612, 31 August to 25 September 2026): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 2026-10-02)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.