NX Reuse Library: The Short Version
An NX reuse library is the set of standard parts, purchased parts, features, profiles and product templates that Siemens NX designers drag in from the Reuse Library instead of modeling them. inteliScience, a Siemens NX partner from Cluj-Napoca, sets it up with classes, attributes and one owner per class. Result: designers find a part before they model it.
The Problem: Designers Model What They Cannot Find
Every NX team has a reuse library on paper. In practice, a designer opens it, clicks through three folders, gives up and models the M8 screw, the bearing block or the cable gland again. Twenty minutes later the part exists twice, under two numbers.
Siemens said it bluntly on its own Teamcenter blog: “for many engineers, it is easier to create a part from scratch than find an existing part that can be re-used” (Siemens Teamcenter blog, 2017). Survey data points the same way. In a 2014 Tech-Clarity survey of 248 manufacturers, engineers reported spending a third of their time on non-value-added work; searching for information made up 23 percent of that lost time, and recreating data they could not find another 12 percent. The same report puts the time spent working with outdated information at 20% (Tech-Clarity, 2014). The figures are not new. The pattern behind them has not changed.
None of this is a tooling gap. NX has had a Reuse Library navigator for many releases, and Siemens lists reusable designs, standard parts, design features, symbols, 2D sections, profiles, curves, shapes and product templates as content that designers locate and drag and drop into a design (Siemens, Reuse of CAD data).
What fails is everything around the navigator. Three failure modes come up again and again: duplicates, outdated parts and classes nobody owns. They share one root. The library is run as a folder, not as a product with an owner, an intake and a way out.
Our position: a small library that designers trust beats a large one they search around.
What Belongs in an NX Reuse Library (and What Stays Out)
An NX reuse library holds objects that recur across products and that the company wants used the same way every time: standard parts, released purchased parts, company features and profiles, approved assemblies and product templates. One-off parts, project geometry and anything without an owner stay out. The admission rule matters more than the folder tree.
| Content type | Examples | Admit when | Keep out |
|---|---|---|---|
| Standard parts | ISO and DIN screws, nuts, washers, pins, retaining rings | Standard, size and grade are on the preferred list | Sizes and grades purchasing does not stock |
| Purchased parts | Bearings, cylinders, sensors, cable glands | Supplier released, ERP item exists, model reworked | Raw supplier STEP downloads |
| Features and profiles | Company slots and bores as user-defined features, 2D sections, extrusion profiles | The geometry is a company standard with fixed parameters | Shapes copied from one project |
| Approved assemblies | Linear unit, clamping set, standard frame corner | Released and used in more than one product | Assemblies still in development |
| Product templates | Parametric parts with PMI and drawing | The part family is stable | Start parts for File New |
Standard and purchased parts
Standard parts are the obvious start and the place where duplicates hurt most. The library should offer the preferred subset that purchasing actually stocks, not the full range of ISO 4762. Every size that is technically possible but never ordered is an invitation to design in a part that has no supplier.
Purchased parts need rework before admission. A designer needs the envelope, the mounting interfaces, the correct mass and the attributes, not every internal detail of the supplier model. A supplier STEP file dropped into the library unchanged slows large assemblies, arrives without your attributes and, sooner or later, sits next to a second copy of itself under the supplier’s own name.
Features, profiles and 2D sections
Company features are underrated library content. A standard slot for T-nuts, a sealing groove, a hole pattern for your own motor flange: as user-defined features with fixed parameters, they produce the same geometry on every part, and a checker can recognize them. Extrusion profiles and 2D sections work the same way for frames and sheet-metal edges.
Approved assemblies and product templates
Approved assemblies (a linear unit, a clamping set, a standard frame corner) save the most time per use, and they age fastest. Admit them only when they are released and already in more than one product.
Product templates go one step further. Siemens describes Reuse Library product templates that carry product and manufacturing information, drawings, motion analysis, structural simulation and validation checking, so that an engineering process is standardized from the moment a designer inserts the template (Siemens, Reuse of CAD data). Start parts are a different thing: they belong in File New, and our guide to setting up and versioning NX templates covers them.
Our clear recommendation: write the admission rule down in one sentence. For example: a part enters the library if it is a standard part from the preferred list, a released purchased part, or a company part used in at least two products. Everything else stays in the project folder.
How to Structure an NX Reuse Library So Designers Find Parts
Structure the library by what a part does, not by project, supplier or the person who modeled it. Keep the class tree shallow, and give every class the attributes a designer would filter by. Someone looking for a screw thinks “fastener, socket head, M8, 25 mm”, not “supplier catalog 2019”.
Finding things is already a large share of design work. In a work-sampling study, 78 design engineers logged their current task once an hour for 20 working days, and acquiring and providing information added up to 55.75% of their working time (Robinson, 2010). Every extra level in the library tree adds to that share, and every search that fails ends in a new part.
Classes by function, three levels deep
Three levels are enough for most machine-building libraries: a domain, a family and a class. If a designer needs more than three clicks to reach a class, they will type a name into search instead, and name search is where duplicates begin.
| Domain | Family | Class | Attributes designers filter by |
|---|---|---|---|
| Fasteners | Screws | Hexagon socket head cap screws | Standard, thread, length, strength class, finish |
| Bearings | Rolling bearings | Deep groove ball bearings | Bore, outer diameter, width, seal type |
| Pneumatics | Cylinders | Compact cylinders | Bore, stroke, mounting style |
| Electrical | Cable glands | Metric cable glands | Thread, cable diameter range, IP rating |
| Profiles | Aluminum profiles | 40 series | Size, slot width, length rule |
Attributes that make a class searchable
Names are the weakest index a library can have. The same Siemens blog post notes that “naming is notoriously inconsistent” and varies by engineer. Attributes do the work names cannot. Each class defines a small set (designation, size, material, finish) with fixed value lists wherever possible, using the same attribute titles that your title block, BOM export and Teamcenter mapping already read. A library part that arrives with these filled carries them into every assembly and drawing that uses it.
When attributes fail, search by shape. Siemens describes Geolus shape search as a way to “find all candidate parts, no matter how they are named”; it finds similar parts regardless of position, orientation or mirroring, from any system that exports JT, STL or VRML. Shape search does not replace a structure, but it is the safety net for the parts that were classified badly.
Teamcenter Classification vs a File-Based NX Reuse Library
If your NX data is managed in Teamcenter, build the reuse library on Teamcenter Classification. A file share next to it turns into a second, competing standard sooner or later. A file-based library is fine for native NX teams at one site, as long as designers can only read it and one person owns it.
In native NX, the Reuse Library navigator shows folders on a file share that the CAD administrator makes available on every seat. Parts are files, the folder tree is the classification, attributes are part attributes, and versioning is whatever the folder convention says.
In Teamcenter-managed NX, the Reuse Library can show the Teamcenter Classification hierarchy instead. Classification arranges items in groups and classes, each class defines its own attributes, and every classified item carries values for them, so a designer filters by bore or thread length before dragging a part into the assembly. The part itself is a Teamcenter item with revisions, release status, access rules and a where-used history.
| Criterion | File-based library (native NX) | Teamcenter Classification |
|---|---|---|
| Where parts live | Folders on a file share | Items in Teamcenter, classified into classes |
| How designers search | Folder tree, file names, part attributes | Class tree plus filters on class attributes |
| Versions and release | Folder conventions; nothing stops an edit | Revisions with release status |
| Where-used | Searching assemblies on disk | Where-used query on the item |
| Access control | File system rights | Teamcenter access rules |
| Link to ERP | Mapped by hand | Item ID shared with the BOM transfer |
| Setup effort | Low | Higher: class model, attributes, classifying existing parts |
| Fits when | One site, native NX, a library one person can still oversee | NX already runs with Teamcenter, several sites or teams |
We’d advise against running both as equals. Our team has seen what that costs: in earlier positions, our engineers built a central reuse library for routing components, because the same components lived in the NX Reuse Library, in Teamcenter and in a third-party electrical engineering system, with nothing keeping the three aligned. The difficult part was not the software. It was agreeing which system is authoritative when two of them disagree.
Moving a file-based library into Teamcenter is a data project, not an import. Map the folder tree to classes, define the attributes per class, and remove duplicates before the import. Import them, and Teamcenter will manage your duplicates very reliably.
Library Governance: One Owner, One Intake, One Status per Part
A reuse library stays useful when every class has a named owner, every new part goes through the same short intake, and every part carries a status and a review date. Without these three, the library grows by copying, and designers stop trusting it.
The roles are simple. A library owner, usually in design methods or CAD administration, owns the class model and the rules. Class owners are designers who know the domain (fasteners, pneumatics, electrical) and decide what enters their class. Every designer may request a part. Give the owners time for this explicitly; a library maintained “on the side” is maintained by nobody.
The intake: six steps from request to release
- Request. The designer names the function, the standard or supplier number and the project that needs the part.
- Search first. Class attributes, then shape search. If a match exists, the request ends with a link to it.
- Model or rework to your company’s CAD modeling guidelines: start part, layers, reference sets, simplified purchased geometry.
- Classify and fill attributes. Class, attribute values, and the link to the ERP item.
- Review by the class owner. Geometry, attributes, mass, interfaces.
- Release. Status released, review date set, visible in the library.
Keep it fast. If a request takes weeks, the designer models the part locally, and the duplicate is created anyway.
Our team has built a library like this to company standards before, in earlier positions: standard parts, features, approved assemblies and templates that designers insert into NX and Teamcenter with names, attributes and metadata already right. What carried over into how we set up libraries today: the quality of a library is decided at intake, not by the tool that inserts the part. We keep one register entry per library part, with the same fields the intake fills:
# One entry in an NX reuse library register (illustrative values)
- id: LIB-FAS-0412
class: "Fasteners / Screws / Hexagon socket head cap screws"
designation: "ISO 4762 M8x25 8.8 zinc flake"
attributes: {STANDARD: "ISO 4762", SIZE: "M8x25", MATERIAL: "steel 8.8", FINISH: "zinc flake"}
source: "Purchased standard part, modeled to the company guideline"
status: released # requested -> in review -> released -> obsolete
owner: "Class owner fasteners"
erp_item: "linked at release"
reviewed: "2026-09-30"
review_interval_months: 12
successor: null # set when obsolete; never delete the part
Retire parts, never delete them
Deleting a library part breaks every assembly that still loads it. Retire it instead: set an obsolete status, name the successor, check where it is used, and hide it from the library view so new designs pick the replacement. Old assemblies keep loading, and the next designer sees why the part is gone.
Test the library against every NX release
Siemens ships two NX releases a year. The June 2026 release (Designcenter 2606, announced on 23 June 2026) also renamed Designcenter NX to Designcenter (Siemens Designcenter blog), and Designcenter 2612 went through an early access program from 31 August to 25 September 2026. Before each upgrade, load a sample of library parts and one assembly per class in the new version, check that library folders and classification views still resolve, and update one product template end to end.
A clean library on one share is a prototype. What’s missing for production: a class model and attribute list your methods team owns, an intake that answers within days, owners with time for it, the same library on every seat or in Teamcenter, and a cleanup of the duplicates already out there. We look at your reuse library together with templates and guidelines in a free first call with an NX engineer, with your own parts.
Five Failure Modes of an NX Reuse Library
Reuse libraries fail in five recognizable ways: duplicates, outdated parts, classes without an owner, local copies next to the library, and a library that admits everything. Each leaves traces in the data, so you can find them in an audit before designers lose patience.
| Failure mode | What you see | Root cause | Countermeasure |
|---|---|---|---|
| Duplicates | The same screw under two numbers; one bracket in two team folders | No search before create, no intake | Search as step 2 of intake; consolidate with a named successor |
| Outdated parts | Withdrawn standards and discontinued purchased parts still on offer | No review date, nothing ever retired | Review interval per class; obsolete status with successor |
| No owner | Requests pile up; nobody can say whether a part is approved | The library is treated as an IT folder | Named owner per class, with time budgeted |
| Local copies | “My parts” folders; library parts edited in place | Intake too slow, library writable | Read-only library, intake measured in days |
| Everything admitted | Thousands of one-off parts; every search returns noise | No admission rule | One-sentence admission rule, enforced at intake |
In practice, most libraries do not fail because of the tool. They fail at the third row, and the other four follow.
Auditing a file-based library with NXOpen
For a native library, a short journal shows where you stand. The one below uses the general NXOpen Python API to read the library attributes of every part in a folder tree. It lists parts without an owner, status or review date, obsolete parts that are still offered, and two kinds of duplicate candidates: parts with the same designation, and byte-identical files under different names.
# NX reuse library audit: owner, status, review date and duplicate
# candidates for every part in a native library folder tree.
# NXOpen Python, general API. Batch example:
# run_journal library_audit.py -args D:\NX_Library C:\nx-audit\library_audit.csv
import csv
import datetime
import hashlib
import os
import sys
from collections import defaultdict
import NXOpen
# Library spec (example values; take yours from the written library rules).
REQUIRED = ["DESCRIPTION", "STANDARD", "SIZE", "MATERIAL", "LIB_OWNER", "LIB_STATUS", "LIB_REVIEWED"]
REVIEW_DAYS = 365
STRING = NXOpen.NXObject.AttributeType.String
def value(part, title):
if not part.HasUserAttribute(title, STRING, -1):
return ""
return part.GetUserAttributeAsString(title, STRING, -1).strip()
def check(attrs, today):
findings = ["missing " + t for t in REQUIRED if not attrs[t]]
if attrs["LIB_STATUS"].upper() == "OBSOLETE":
findings.append("obsolete but still in library")
if attrs["LIB_REVIEWED"]:
try:
age = (today - datetime.date.fromisoformat(attrs["LIB_REVIEWED"])).days
if age > REVIEW_DAYS:
findings.append("review overdue (%d days)" % age)
except ValueError:
findings.append("review date not ISO")
return findings
def main(root, out_csv):
session = NXOpen.Session.GetSession()
today = datetime.date.today()
rows, by_designation, by_content = [], defaultdict(list), defaultdict(list)
for folder, _, files in os.walk(root):
for name in sorted(f for f in files if f.lower().endswith(".prt")):
path = os.path.join(folder, name)
rel = os.path.relpath(path, root)
try:
part, load_status = session.Parts.Open(path)
load_status.Dispose()
except NXOpen.NXException as exc:
rows.append({"part": rel, "owner": "", "status": "", "findings": "cannot open: %s" % exc})
continue
attrs = {t: value(part, t) for t in REQUIRED}
part.Close(NXOpen.BasePart.CloseWholeTree.TrueValue,
NXOpen.BasePart.CloseModified.CloseModified, None)
if attrs["STANDARD"] and attrs["SIZE"]:
key = " ".join(attrs[t].upper() for t in ("STANDARD", "SIZE", "MATERIAL"))
by_designation[key].append(rel)
with open(path, "rb") as f:
by_content[hashlib.sha1(f.read()).hexdigest()].append(rel)
rows.append({"part": rel, "owner": attrs["LIB_OWNER"], "status": attrs["LIB_STATUS"],
"findings": "; ".join(check(attrs, today))})
# Mark duplicate candidates: same designation, or identical file content.
for label, groups in (("same designation as", by_designation), ("identical file to", by_content)):
for parts in groups.values():
if len(parts) > 1:
for row in rows:
if row["part"] in parts:
others = ", ".join(p for p in parts if p != row["part"])
row["findings"] = "; ".join(x for x in (row["findings"], label + " " + others) if x)
with open(out_csv, "w", newline="") as f:
writer = csv.DictWriter(f, fieldnames=["part", "owner", "status", "findings"])
writer.writeheader()
writer.writerows(rows)
if __name__ == "__main__":
root, out_csv = sys.argv[-2:] # the two values passed after -args
main(root, out_csv)
Run it once before you change anything, and again after the first intake month. The journal only catches duplicates that share a designation or a file. Copies with different names and slightly changed geometry need shape search, either Geolus in Teamcenter or a geometric index across all your CAD data. For a Teamcenter-managed library, the same questions (no owner, no review date, obsolete but still classified) become saved queries or reports on the classified items.
Frequently Asked Questions
What is the Reuse Library in Siemens NX?
The Reuse Library is a navigator in Siemens NX that gives designers access to reusable content (standard parts, purchased parts, user-defined features, 2D sections, profiles, symbols and product templates), which they drag and drop into a part or assembly instead of modeling it again. In native NX it shows library folders on a file share; in a Teamcenter-managed installation it can show the Teamcenter Classification hierarchy and filter parts by class attributes. What the library contains, and who keeps it current, is a company decision rather than an NX setting.
Teamcenter Classification vs a file-based NX reuse library: which should you use?
If NX already runs with Teamcenter, use Teamcenter Classification: library parts then become Teamcenter items with revisions, release status, access control and where-used, and classification adds search by class attributes. A file-based library on a share is simpler and works for a single site with native NX, but it relies on folder conventions and file rights to stop uncontrolled edits. Running both side by side as equal sources is the setup we would avoid, because the two drift apart.
How do you prevent duplicate parts in a CAD standard parts library?
Make “search before create” the first step of the intake: search by class attributes first, then by shape, and admit a new part only when both come back empty. Shape search such as Geolus in Teamcenter finds similar parts regardless of name, position or orientation, which catches the duplicates that attribute search misses. Duplicates already in the library should be consolidated to one master part, with the others set to obsolete and pointing to it, not deleted.
How do you keep an NX reuse library up to date?
Give every class a named owner, put a release status and a review date on every part, and retire parts with an obsolete status and a named successor instead of deleting them. A periodic audit, for example with an NXOpen journal on a file-based library or saved queries in Teamcenter, lists parts without an owner, overdue reviews and obsolete parts still on offer. Test a sample of library parts and templates before every NX upgrade.
How much does it cost to set up an NX reuse library?
There is no list price, because the effort depends on the number of classes, the share of purchased parts that need rework, and whether existing parts must be deduplicated and classified in Teamcenter. Most of the cost is internal design and methods time for the class model, the intake and the cleanup; the NX Reuse Library itself comes with NX. inteliScience offers a free first call with an NX engineer and a one-week NX Engineering Assessment for €4,900 fixed that scores the reuse library together with templates, guidelines and the release flow.
Next Step
Bring your library folder or classification tree and twenty parts your team modeled last month. In a free 60-minute call, inteliScience’s Siemens NX engineers from Cluj-Napoca check how many of them already existed in the library, where designers lose the trail and what owners and an intake would change, under NDA. Talk to an NX engineer about your reuse library
Related Topics
- Engineering process optimization for NX design teams
- Finding duplicate parts by geometry, not names
- How NX and Teamcenter work together from the first check-in
References
- Siemens, “Reuse of CAD data” (Designcenter NX Reuse Library, product templates, Geolus shape search): https://www.siemens.com/en-us/products/designcenter/nx-cad-software/mcad/reuse-cad-data/ (retrieved 9 October 2026)
- Argyle, E., “Shape search for parts so you can re-use”, Siemens Teamcenter blog, 2 May 2017: https://blogs.sw.siemens.com/teamcenter/shape-search-for-parts-so-you-can-re-use/ (retrieved 9 October 2026)
- Tech-Clarity, “Tech-Clarity Perspective: Reducing Non-Value Added Work in Engineering”, 2014 (248 survey responses): https://tech-clarity.com/documents/Tech-Clarity-Perspective-DDAa.pdf (retrieved 9 October 2026)
- Robinson, M. A., “An empirical analysis of engineers’ information behaviors”, Journal of the American Society for Information Science and Technology 61(4), 640-658, 2010: https://doi.org/10.1002/asi.21290 (retrieved 9 October 2026)
- Siemens Designcenter blog, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 9 October 2026)
- Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 9 October 2026)