NX Post Builder vs Post Configurator: Stay or Switch (2026)

NX Post Builder vs Post Configurator: The Short Version

NX Post Builder vs Post Configurator compares Siemens’ two tools for NX CAM postprocessors. Post Builder edits self-contained posts and stopped development with the 1953 series. Post Configurator layers your changes on Siemens-maintained controller logic and gets new features. Existing posts keep running. inteliScience CAM engineers build new posts in Post Configurator, proven on your machine.

Question NX Post Builder NX Post Configurator
Status in 2026Final release, no new featuresCurrent Siemens tool for NX CAM posts
How a post is builtOne self-contained post, edited in placeYour layer on top of Siemens base and controller layers
Siemens Post Hub libraryNot built with itEvery Post Hub post is built with it
Your existing postsKeep running in NXConverter add-on (NX CAM 2606) or a rebuild

The Problem: Your Posts Work, but the Tool Behind Them Stopped Moving

If your shop has used NX CAM for more than a few years, the posts driving your machines were very likely built in Post Builder: Post Configurator only arrived in March 2015. Those posts usually work, which is exactly why nobody touches them.

The trouble starts with the next change. A new probing cycle, a second machine of the same type, an NX upgrade, or the retirement of the engineer who knew what each custom command does. Meanwhile Siemens has stopped developing Post Builder, built its whole Post Hub library in Post Configurator and offers an add-on, current for NX CAM 2606, that converts Post Builder posts automatically.

So the real question is which posts stay, which move, and in what order. That decision is what this article covers. How an NX CAM post works, where Post Hub kits fit in and how to buy off a post on the machine is explained in our guide to NX CAM postprocessors.


What Each Tool Is

Both tools produce the same kind of program: Tcl event handlers that the Manufacturing Output Manager (MOM) in NX calls as it walks through your operations, from program start to tool change to a drilling cycle. They differ in how the post is organized and in who maintains which part of it.

Post Builder: one post, edited in place

Post Builder is a separate application with its own Tcl/Tk interface. Each post consists of a .tcl file with the event handlers, a .def file with the output formats and a .pui file that Post Builder uses to reopen it. Whatever the dialogs do not cover goes into custom commands, Tcl procedures named PB_CMD_.

A new post starts as a copy of a controller template. From then on it is entirely yours: easy to read, easy to copy, and the reason a shop ends up with several slightly different versions of the same Fanuc post.

Post Configurator: your layer on a Siemens library

Post Configurator runs inside NX CAM and first shipped with NX 10.0.1 in March 2015, as Siemens’ Post Configurator enablement slides from 2016 show. A post is a stack of layers, listed there from bottom to top: base, controller (Sinumerik, Fanuc and others, encrypted and not editable), machine tool builder, OEM, machine series, service and customer.

Most settings are dialog properties with context help. Tcl covers the rest and goes into your own layer. “Promote re-use rather than re-write” was Siemens’ own slogan for the design.

The two formats do not mix: neither tool opens the other’s posts.


NX Post Builder vs Post Configurator Side by Side

For the NC programmer at the Postprocess dialog, little changes: posts from either tool are selected the same way and should write the same NC code. The differences show up for whoever edits the post, licenses it and retests it after an NX upgrade.

Aspect NX Post Builder NX Post Configurator
Where you workSeparate application with a Tcl/Tk interfaceInside NX CAM
How a post is organized.tcl event handlers, .def formats, .pui for Post BuilderSiemens base and controller layers, machine layers, your own layer on top
Changes beyond the dialogsCustom commands (PB_CMD_ procedures) inside the postProperties first, Tcl in your own layer
Controller knowledgeTemplate copied into the post when it is createdController layers that Siemens maintains
Development statusStopped with the 1953 seriesComplete production status since NX 1899, still developed

The status row decides where new functionality lands. NX for Manufacturing 2606, released on 19 June 2026, added Tcl snippets in CAM Notes that run as Post Configurator commands during NC output, plus tool-setting and probing cycles whose output goes through the postprocessor layers. A Post Builder post gains none of that by itself.

The controller row matters just as much. Improvements to a Post Builder template never reach the posts copied from it, while a Post Configurator post sits on a controller layer that Siemens keeps maintaining.


Why Siemens Moved to Post Configurator

Siemens moved to Post Configurator to get away from one-off posts that each carry their own copy of the controller logic. The shift took about ten years, and Siemens’ own advice changed on the way, which is why old forum threads say “don’t migrate” while current Siemens material says “convert”.

Date What happened
March 2015First Post Configurator release with NX 10.0.1: single-channel milling machines up to 5 axes, Sinumerik, Fanuc and other controllers
November 2016Siemens calls Post Configurator “not an extension or replacement for Post Builder” and advises against migrating posts that work “at this time”
February 2020Post Hub launches, free to NX CAM users, with more than 1,100 postprocessors, all developed with Post Configurator (Siemens NX Manufacturing blog)
July 2021A member of Siemens’ Post Configurator team confirms that Post Builder development stopped with the 1953 series, that Post Configurator reached complete production status with NX 1899, and recommends it for new projects and for converting old posts (Siemens Community)
19 June 2026With NX CAM 2606, a Siemens Community tech tip describes an add-on that converts Post Builder posts automatically and preserves existing customizations (Siemens Community tech tip)
September 2026Siemens previews the next release, 2612, in its Early Access Program (virtual 31 August to 4 September, on site 14 to 25 September)

Read the 2016 advice in context. Siemens then recommended Post Configurator only within limits (single channel, up to five axes), and no converter existed. Both have changed, as the 2021 and 2026 rows show. The 2021 answer also expected the Post Builder application to leave the NX installation within one to three years. Training moved the same way: Siemens’ four-day instructor-led Post Configurator course (ILT045003) is now listed as no longer offered.

Ten years in, the direction is settled. Only the pace of your own move is still open.


What Changes for Existing Post Builder Posts

Nothing breaks on the day you decide. Post Builder posts are Tcl programs on the same MOM architecture as Post Configurator posts, and Siemens has stated that Tcl posts, including Post Builder posts, will continue to run. What changes is everything around the post.

Editing and new features

Post Builder still edits your posts but gains no new features; new post functions such as the 2606 probing output arrive in Post Configurator. For any post you plan to extend, that alone settles the question.

Conversion is the start, not the proof

The 2606 add-on is the right starting point. Siemens says it preserves existing customizations; treat that as a claim to test. Every PB_CMD_ procedure of the old post must reappear in the new layer and write the same output. Versions matter as well: a user in the Siemens Community reported that an earlier converter, built for NX 1899, stopped with a version error in NX 2306.

Conversions fail quietly. The post runs, and one cycle, one clamp command or one header line comes out different. Only reference programs posted with both versions and compared line by line will show it.

Licenses, protection and skills

Siemens’ 2016 material lists three Post Configurator license levels: Basic (free with NX CAM, runs posts), Advanced (NX31439, creates posts and changes settings) and Full (NX31440, adds Tcl customization and encryption). Bundles have changed since, so check your license file before you plan in-house post work.

Encrypted layers (.pce files), which can also be tied to Siemens Sold-To IDs or an expiry date, cannot be decrypted. A post bought from a vendor may therefore contain logic you can neither read nor convert. If you encrypt your own layers, keep the original Tcl.

The skills stay close to Post Builder: Tcl, MOM events and variables, plus Post Configurator’s concepts. Teams that want to maintain their own posts can learn it in our NX Post Configurator training, with an optional module on Post Builder migration.

First, count what you have

Before deciding, list your posts. This script reads template_post.dat, where NX registers its posts, detects the header that Post Builder writes into each .tcl file, and counts the PB_CMD_ custom commands:

# Inventory of NX CAM posts registered in template_post.dat
# Python 3, standard library only.
# Usage: python post_inventory.py "D:\nx_posts\template_post.dat" > posts.csv
import csv
import os
import re
import sys


def classify(tcl_path):
    """Return (tool, Post Builder version, custom command count) for a post."""
    try:
        with open(tcl_path, encoding="latin-1") as f:
            text = f.read()
    except OSError:
        return ("file not found", "", 0)
    header = re.search(r"with Post Builder version\s+([\w.]+)", text)
    custom = len(re.findall(r"^proc PB_CMD_", text, re.MULTILINE))
    if header:
        return ("Post Builder", header.group(1).rstrip("."), custom)
    return ("not Post Builder, check", "", custom)


def main(dat_file):
    out = csv.writer(sys.stdout)
    out.writerow(["post", "tcl_file", "tool", "pb_version", "pb_custom_commands"])
    with open(dat_file, encoding="latin-1") as f:
        for line in f:
            line = line.strip()
            if not line or line.startswith("#"):
                continue
            parts = [p.strip() for p in line.split(",")]
            if len(parts) < 2:
                continue
            # Entries look like NAME,${UGII_CAM_POST_DIR}post.tcl,${UGII_CAM_POST_DIR}post.def
            # If a ${...} variable stays unresolved, set it in your shell and run again.
            tcl_file = os.path.expandvars(parts[1])
            tool, version, custom = classify(tcl_file)
            out.writerow([parts[0], tcl_file, tool, version, custom])


if __name__ == "__main__":
    main(sys.argv[1])

Posts not flagged as Post Builder may be Post Configurator, Post Hub or hand-written posts; open them in Post Configurator to confirm. The command count includes those inherited from the controller template, so compare posts with each other rather than reading it as your own changes.

A converted post that runs in NX is a POC. What’s missing for production: reference programs posted with the old and the new post and compared line by line, a test part on the machine, and an acceptance protocol that names the post version and the NX release. Our CAM engineers do exactly this in NX postprocessor development: new posts from €5,000 for one 3-axis milling machine, migrations quoted after a requirements questionnaire.

The migration itself, from inventory and baseline to conversion, comparison and machine test, is described step by step in our guide to moving posts from Post Builder to Post Configurator.


When to Stay on Post Builder and When to Switch

Stay where a Post Builder post drives a machine that will not change and will leave within a few years. Switch for every new post, for any post you keep extending, and for posts nobody can explain anymore. Our clear recommendation for 2026: no new posts in Post Builder, and no big-bang conversion of all old ones either.

Your situation Our recommendation
New machine, or a post written from scratchPost Configurator, starting from the controller library or a Post Hub post. No exceptions in 2026
Post Builder post that runs well, rarely changes, machine leaves in two to three yearsStay. Freeze the post, version it, keep reference programs and retest on every NX release
Post that needs new functions soon (probing, tool setter, new cycles)Switch first, then add the functions in your Post Configurator layer
Post nobody understands, author gone, no test programsSwitch, but build a baseline of reference programs before converting anything
Several near-identical posts for one controller familySwitch in waves: one machine first, then reuse its layer for the others
Encrypted post from a vendor, no Tcl sourceAsk the vendor. Without the source there is nothing to convert
Your team wants to own its postsSwitch, and train the people who will maintain them

“Stay” still means work: a post that stays needs a version number, reference programs and a retest before each of the two NX releases a year goes into production.

We’d advise against converting posts in the same window as an NX upgrade. If the NC output changes, you will not know whether the upgrade or the conversion caused it. Convert and accept on the release you run today, then upgrade.

Start with the post that costs you the most today, the one with hand edits at the control or the one nobody dares to open. The easiest post teaches you little that the next migration can use.


Frequently Asked Questions

Is Siemens NX Post Builder discontinued in 2026?

Post Builder is no longer developed, but it has not disappeared. A member of Siemens’ Post Configurator team confirmed in 2021 that development stopped with the NX 1953 series, and Siemens offers an add-on, current for NX CAM 2606, that converts Post Builder posts to Post Configurator. The CAM product notes of each NX release state whether the Post Builder application still ships with it.

Do Post Builder postprocessors still run in NX CAM 2606?

Yes. Post Builder posts are Tcl programs on the same Manufacturing Output Manager (MOM) as Post Configurator posts, and Siemens has stated that Tcl posts, including Post Builder posts, will continue to run. They do not gain the new post functions Siemens adds to Post Configurator, and like any post they should be retested with reference programs before a new NX release goes into production.

Is Post Configurator better than Post Builder for NX CAM postprocessors?

For new posts, yes. In the NX Post Builder vs Post Configurator choice, only Post Configurator builds on controller layers that Siemens maintains, keeps your customizations in a separate layer and is the tool behind Post Hub. For a Post Builder post that runs well on a machine that will not change, switching brings little immediate benefit. The deciding question is whether the post will change again; if it will, move it first.

Which license do you need to create postprocessors with NX Post Configurator?

Running Post Configurator posts is included in NX CAM; creating and customizing them needs a higher level. Siemens’ 2016 enablement material lists Basic (free, runs posts), Advanced (NX31439, creates posts and changes settings) and Full (NX31440, adds Tcl customization and encryption). Check your current license file or ask your Siemens reseller, since bundles have changed since then.

How much does it cost to move an NX postprocessor from Post Builder to Post Configurator?

There is no list price, because the effort depends on the custom commands, the controller, rotary axes and the testing your machine needs; Siemens’ tech tip names no price for the converter add-on either. Plan for the proof as well as the conversion: reference programs, a line-by-line comparison of NC output and a test part. At inteliScience, migrations are quoted after a requirements questionnaire, and a new post for one 3-axis milling machine starts at €5,000.


Next Step

If your shop runs Post Builder posts today, the most useful next hour sorts them: keep, convert or rebuild, and in what order around your next NX upgrade. inteliScience, a Siemens NX specialist based in Cluj-Napoca, Romania, goes through your post list with you and tells you plainly where the converter is enough.

Talk to our CAM engineers about your Post Builder posts


Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.