NX PMI Tutorial 2026: Add PMI in Siemens NX Step by Step

NX PMI Tutorial: The Short Version

This NX PMI tutorial shows, in eight steps, how to put dimensions, datums, GD&T and notes on the 3D model in Siemens NX, organize them in model views, show component PMI in assemblies and let the drawing inherit it. inteliScience’s Siemens NX engineers from Cluj-Napoca teach this workflow on customers’ own parts. Result: no dimension is typed twice.

Step What you do Where in Siemens NX
1. StandardSet the drafting standard and PMI preferences, ideally in the templateCustomer Defaults > Drafting > General/Setup > Standard; File > Preferences > PMI
2. Work view and planeMake the target model view the work view, check plane and associated objectsMBD Navigator > Model Views > double-click the view
3. DatumsDatum feature symbols on the datum facesPMI tab > Annotation > Datum Feature Symbol
4. GD&TFeature control frames that reference the datumsPMI tab > Annotation > Feature Control Frame
5. Dimensions and notesSize dimensions, notes, surface finishPMI tab > Dimension > Rapid Dimension
6. Model viewsOne view per reading task, PMI shown where it belongsMBD Navigator > Add View; right-click PMI > Display > in Views
7. AssemblyComponent PMI shown in an assembly viewMBD Query > Create Model View; WAVE PMI Linker for copies
8. DrawingDrafting views inherit PMI from model viewsDrafting Preferences > Drawing View > Common > PMI

The Problem: PMI That Looks Right and Fails Downstream

Placing a PMI dimension in Siemens NX takes a few clicks. Placing it so that the drawing, the assembly and the inspection department can still use it after the next design change is where first attempts go wrong.

The failures repeat from team to team. The dimension lands in whichever model view happened to be the work view, so nobody finds it. It floats without associated faces, a label rather than a definition. The drawing gets the same values typed in again because no drafting view inherits PMI. And an assembly opened with a lightweight load shows PMI as retained, which looks like broken data and is only a load option.

None of this is a software limit; it is the order of steps. Get the order right and PMI pays off downstream: on a high-volume powertrain line documented by Siemens, the PMI-based approach “has saved 50 percent or more of typical CMM programming time” (Siemens NX Manufacturing blog, July 2021). That only works when PMI is attached to geometry and carries its meaning as data, the difference we unpack in MBD vs PMI and why semantic PMI matters.

A note on versions. The command paths below follow the Siemens NX help for the NX 2306 series. Ribbon groups move between releases: the current one is Designcenter 2606 (23 June 2026), with which Siemens renamed Designcenter NX to simply Designcenter, and 2612 went through Siemens’ Early Access Program from 31 August to 25 September 2026. If a path differs on your seat, type the command name into Command Finder.


Step 1: Set the Standard and PMI Preferences First

PMI and Drafting in Siemens NX share one set of standards. The Drafting Standard customer default configures annotation and dimension settings to ASME, DIN, ESKD, GB, ISO, JIS or Shipbuilding, and NX applies it to PMI and drawings alike. Set it before the first annotation, because a later change does not touch existing PMI.

Three levels decide what your PMI looks like, and they act at different moments:

Level Where in NX What it controls When it takes effect
Customer defaultFile > Utilities > Customer Defaults > Drafting > General/Setup > Standard tabThe standard behind all annotation and dimension defaultsNew PMI and drawings only; existing objects keep their settings
Part preferencesFile > Preferences > PMIAnnotation plane, display in model views, text, dimension and tolerance formatNew PMI in this part; a PMI preference also sets the matching Drafting preference
Session resetTools > Drafting Standard, in the Drafting applicationReloads a standard file into the current preferencesResets PMI and Drafting preferences together

Before you annotate, switch on the PMI application (Application tab > Design group > PMI, or File > All Applications > PMI). Then check two settings under File > Preferences > PMI > PMI General/Setup > Display. Clear Display in all Views in the Create group if PMI should appear only in the view where you create it. In the Annotation Plane group, Plane = Model View Plane puts new PMI on the plane of the current model view, which is what you want for views that later become drawing views.

Our clear recommendation: put the standard, units and PMI preferences into the part template, not into individual parts. The NX help states that changes to customer defaults “do not affect existing PMI and Drafting objects” (NX help, Setting customer defaults for PMI). A standard fixed on part ten leaves parts one to nine as they were.


Steps 2 to 5: Datums, GD&T and Dimensions on the 3D Model

Every PMI object in Siemens NX sits on an annotation plane and should be associated with the faces, edges or bodies it controls. Pick the work view first, because new PMI lands only there. Then place datums, then the feature control frames that reference them, and size dimensions and notes last.

Step 2: Work view, annotation plane and associated objects

Open the MBD Navigator on the Resource bar, expand Model Views and double-click the view you want to annotate; NX appends (Work, Displayed) to its name. In an assembly, new PMI goes into the work view of the assembly part. Make a component the work part and the PMI goes into the component instead.

NX infers the annotation plane from the geometry you select and falls back to the Plane preference from step 1; the active plane shows as a highlighted datum. Specify Plane in the Orientation options of any PMI dialog defines your own, and Lock Plane (right-click in the graphics window background) keeps the next PMI on the same plane.

Then the part most people skip. Every PMI dialog has an Associated Objects group for the edges, faces, bodies or components the PMI applies to. A note can have one leader to one face and still be associated with all six faces it specifies. PMI without associated objects displays and prints, but nothing downstream knows what it controls.

Step 3: Datum feature symbols

Choose PMI tab > Annotation group > Datum Feature Symbol, type the letter in the Datum Identifier group and associate the datum faces. With a leader, set the leader type to Datum and click Select Terminating Object; NX adds the face you click as an associated object. Repeat for B and C.

We’d advise against starting with dimensions. The datum reference frame decides how the part is fixtured and inspected, and every feature control frame you add later refers to those letters. Teams that dimension first end up re-attaching tolerances once the datums are agreed.

Step 4: Feature control frames

Choose PMI tab > Annotation group > Feature Control Frame and place the symbol; its content is then set on the Feature Control Frame > General tab of the ribbon. The NX help example for a single frame is a typical position tolerance:

  1. Place the frame and, under Associated Objects, select the face of the feature.
  2. Characteristic: Position.
  3. Tolerance: value 0.3, with zone shape and maximum material condition set in the Tolerance group.
  4. Datum references: primary A, secondary B, tertiary C.
  5. Leader: Select Terminating Object, then OK.

Step 5: Dimensions, notes and surface finish

Rapid Dimension (PMI tab > Dimension group) infers the type from your selection: horizontal, vertical, point-to-point, perpendicular, cylindrical, angular, radial or diametral. Linear, Radial, Angular, Chamfer, Thickness, Arc Length and Ordinate sit in the same group for the cases Rapid gets wrong. Notes and surface finish symbols come from the Annotation group and follow the same plane and association rules.

One shortcut tempts every team: Edit > Feature > Feature Dimension, then Display as PMI. The result is associative and edits in both directions, but Siemens warns that such dimensions “only apply to the feature itself, and may not address the fit, form or functional requirements needed to properly dimension the feature” (NX help, Converting feature dimensions to PMI). Use it for driving dimensions that already say what manufacturing needs. Dimension everything else yourself.


Step 6: Organize PMI in Model Views

A model view is a saved orientation plus the PMI that belongs to it, and it is what the drawing, a 3D PDF and the person reading the model will see. NX shows new PMI only in the current work view unless Display in all Views is set, so your view structure decides whether anybody finds the annotations.

Create views in the MBD Navigator: right-click Model Views > Add View makes a user-defined view from the current work view. To move PMI between views, right-click it and choose Display > in Views, in all Views or in Work View; Convert to New Display Instance gives the same PMI its own style and position in one view. PMI section views belong here too, for internal features nobody can dimension from outside.

We build model views around reading tasks, one per future drawing view or inspection setup: datums and position tolerances, a section through the bore, surface finish and notes. Display in all Views works for datum symbols and general notes. For dimensions it produces views nobody can read.

Check what each model view carries

Before you start the drawing, this read-only NX journal in Python counts the PMI display instances in each model view and flags PMI that is retained, shown in no view or not associated with geometry.

# NX journal (Python), read-only: what does each model view carry?
# Counts PMI display instances per model view and flags PMI that is
# retained, shown in no model view or not associated with geometry.
import NXOpen

session = NXOpen.Session.GetSession()
work = session.Parts.Work
lw = session.ListingWindow
lw.Open()

per_view = {view.Name: 0 for view in work.ModelingViews}
findings = []

for pmi in work.PmiManager.Pmis:
    label = f"PMI {pmi.Index}"
    instances = pmi.GetDisplayInstances()
    if not instances:
        findings.append(f"{label}: shown in no model view")
    if any(inst.IsRetained for inst in instances):
        # retained: referenced geometry deleted, suppressed or not loaded
        findings.append(f"{label}: retained")
    for inst in instances:
        for view in inst.GetViews():
            per_view[view.Name] = per_view.get(view.Name, 0) + 1
    assoc = pmi.GetAssociatedObject()
    if assoc is None or not assoc.GetObjects():
        findings.append(f"{label}: no associated objects")

lw.WriteLine("PMI display instances per model view:")
for name, count in per_view.items():
    lw.WriteLine(f"  {name}: {count}")
lw.WriteLine(f"Findings: {len(findings)}")
for line in findings:
    lw.WriteLine("  " + line)

It uses public NXOpen API only: Pmi.GetDisplayInstances and Pmi.GetAssociatedObject (NXOpen .NET reference, Pmi) plus Annotation.GetViews and the IsRetained property (NXOpen Python reference, Annotation). A view with zero PMI, or a long findings list, is cheaper to fix now than after the drawing exists.

Ready to do this on your own parts? Our NX PMI and MBD training for design teams covers every step of this tutorial, from standard setup to supplier export, live online or at your site for up to six participants.


Step 7: Show PMI in an Assembly

PMI lives in the part where it was created. To show component PMI in an assembly view, Siemens NX uses MBD Query; to give CAM or another part an associative copy, it uses the WAVE PMI Linker. PMI that belongs to the assembly itself, such as a note on a fit between two components, is created with the assembly as the work part.

You need NX tool What you get Watch out for
PMI that belongs to the assemblyAssembly as work part, then the commands from steps 2 to 5PMI stored in the assembly partA component set as work part receives the PMI instead
Component PMI visible in an assembly viewMBD Query, then Create Model View or Display > in ViewsComponent PMI displayed in assembly model viewsResults are static; downstream applications cannot reuse component PMI
An associative copy for CAM or another partWAVE PMI LinkerLinked PMI that updates when the source changesNot editable in the target; edit the source part

For the common case, showing component PMI (NX help, MBD Query in assemblies):

  1. Open the assembly and click the MBD Query tab on the Resource bar.
  2. In the Query panel, choose Rule Based Query and a rule such as Find Dimension or Find Datum.
  3. Set the rule parameters and the assembly scope, then click OK.
  4. Select the PMI found, right-click and choose Create Model View, or Display > in Views for an existing view.
  5. After a component’s PMI changes, run the query again.

Load state causes most “broken” assembly PMI. PMI whose geometry is not loaded appears retained, and component-level PMI stays invisible until the component is fully loaded, so check the assembly load options before you edit anything. Since the June 2026 release, Live Share also supports “concurrent multi-user PMI operations” (Siemens, June 2026), which makes clear ownership of assembly and component PMI more important, not less.


Step 8: Pass PMI to the Drawing

You cannot create PMI in the Drafting application. Drafting views inherit it from model views, and each view’s Inherit PMI setting decides which PMI arrives. Set the default once in the drafting preferences and nobody retypes a dimension the model already carries.

Create the drawing with File > New > Drawing tab, Relationship set to Reference Existing Part, and a drawing template. Siemens recommends a template that references the master part over adding the master as a component later. Then open Drafting Preferences > Drawing View > Common > PMI and pick the option in the Inherited group; the Settings of a single view override it.

Inherit PMI option What the drafting view shows When we use it
NoneNo inherited PMI; existing inherited PMI is removed at the next updateOverview and exploded views
From Model ViewAll PMI displayed in the model view placed on the sheetBase views built from dedicated model views (our default)
Aligned to Drawing (View Only)PMI from that model view on annotation planes parallel to the sheetModel views that mix annotation planes
Aligned to Drawing (Entire Part)PMI from any model view on planes parallel to the sheetProjected views of simple parts

What to expect once PMI is inherited, per the NX Drafting help on inherited PMI:

  • Inherited PMI uses the drawing’s annotation preferences and scales with the view.
  • New or semantically changed PMI in the model marks the drawing out of date; the update brings it in, and deleted PMI disappears.
  • Visual edits on the sheet stay on the sheet. Semantic edits reach the model only if the Allow PMI Bidirectional Edits customer default is on.
  • Base, projected, detail and most section views inherit PMI; revolved and folded sections do not, and PMI whose face is cut away stays out.
  • The master must be fully loaded, or inherited PMI stays retained even after an update.

Our rule for drawings is short: never type a dimension on the sheet that PMI already defines. If a sheet should carry only critical characteristics, filter with the PMI Types list in the view settings rather than deleting inherited PMI by hand, which the next update undoes.


Before Release: A PMI Checklist for Siemens NX

Most PMI errors are visible before the part leaves design, if someone looks. This is the list we run on a finished part, in this order.

  1. The part was created from the template with the right drafting standard.
  2. Datums exist before tolerances, and every feature control frame refers to existing datum letters.
  3. Every PMI object has associated objects, and none is retained (the journal above shows both).
  4. Every PMI object appears in at least one named model view, and dimensions are not displayed in all views.
  5. Drawing views inherit PMI, and no inherited value was retyped by hand.
  6. Assemblies were fully loaded before the drawing update.
  7. The STEP AP242 export was checked in a second application.

For item 7, NIST’s free STEP File Analyzer and Viewer (SFA) reports semantic and graphic PMI in a STEP file; version 5.51 came out on 14 September 2026, and the SFA repository had 198 GitHub stars on 9 October 2026. Teams licensed for Model Based Definition can automate items 2 to 4 with PMI Advisor, which checks PMI against ISO or ASME rule sets in Off, Advise or Enforce mode.


Where Rules and AI Come In

The workflow above is manual on purpose. Rules and AI speed it up only when the basics are settled: a standard in the template, datums someone decided, model views people can read.

Rules come first. With the December 2024 release, Siemens shipped “over 100 PMI out-of-the-box and production-ready automation rules” for its MBD tools (Siemens Designcenter blog), which pay off on part families that repeat. What an AI assistant can and cannot do here is covered in our AI-generated PMI experiment in Siemens NX. Neither replaces the decisions in steps 1 to 3.

inteliScience covers both ends within our Siemens NX engineering services from Cluj-Napoca: training for the manual workflow, rules and automation once a part family justifies them. Learn the manual path first. Automation on top of an unreadable model view structure only produces unreadable PMI faster.


Frequently Asked Questions

How do you add PMI to a part in Siemens NX?

You add PMI in Siemens NX with the commands on the PMI tab, such as Rapid Dimension, Datum Feature Symbol, Feature Control Frame and Note, each placed on an annotation plane and associated with faces or edges of the model. Set the drafting standard first, make the target model view the work view, and place datums before tolerances. PMI cannot be created in the Drafting application; drawings inherit it from model views.

How do you show component PMI in a Siemens NX assembly?

Siemens NX shows component-level PMI in an assembly through MBD Query: run a rule such as Find Dimension or Find Datum, then choose Create Model View or Display in Views for the PMI found. The results are static, so rerun the query after a component changes. If CAM or another application must reference the PMI, create an associative copy with the WAVE PMI Linker instead.

Why is PMI not showing in a Siemens NX drawing view?

PMI usually does not appear in a Siemens NX drawing view because the view’s Inherit PMI option is None, an Aligned to Drawing option filters out PMI on non-parallel annotation planes, the master part is not fully loaded, or the associated face is not visible in that view. Check the PMI node in the view’s Settings first, then the load state. Revolved and folded section views cannot show inherited PMI at all.

PMI vs drafting dimensions in Siemens NX: which should you use?

Use PMI whenever the 3D model is, or will become, the reference for manufacturing and inspection, and drafting dimensions only for information that exists on the drawing alone. PMI is associated with model geometry, reusable downstream and inherited into drawing views; drafting dimensions live only on the sheet. Most NX PMI commands mirror their Drafting counterparts, so the switch is about annotation planes and associated objects, not new dialogs.

How much does it cost to use PMI in Siemens NX?

The cost of PMI in Siemens NX has two parts: the license capability and the time to learn it. License prices for the PMI and Model Based Definition capabilities are quoted by Siemens or a reseller and depend on your NX bundle; PMI Advisor, for example, lists Model Based Definition as a prerequisite. For the learning part, inteliScience quotes in-house and live online NX PMI and MBD training after a short call, based on modules and group size.


Next Step

Want your designers to annotate their own parts this way? In a free 60-minute call, inteliScience’s Siemens NX engineers look at one of your annotated parts and the drawing derived from it, and show you where PMI gets lost between model, assembly and sheet. Talk to our NX engineers about PMI on your parts



References

  • Siemens NX help, NX 2306 series, PMI: Introduction to PMI; Setting customer defaults for PMI; PMI annotation planes; PMI associated objects; Create a Datum Feature Symbol; Create a single feature control frame; Rapid dimension; Converting feature dimensions to PMI; PMI visibility in model views; MBD Navigator shortcut menu commands; Display PMI objects for select components in an assembly; WAVE PMI Linker; Effects of assembly load options on PMI; Operating characteristics of inherited PMI: https://docs.sw.siemens.com/documentation/external/PL20221117716122093/en-US/nx_help/nx/2306/nx_help/en-US/pmi/index.html (retrieved 9 October 2026)
  • Siemens NX help, NX 2306 series, Drafting: Setting your Drafting standard; Create a drawing with PMI using the Base View command; Common PMI preferences: https://docs.sw.siemens.com/documentation/external/PL20221117716122093/en-US/nx_help/nx/2306/nx_help/en-US/drafting/index.html (retrieved 9 October 2026)
  • Siemens NX help, NX 2306 series, Model Based Definition: PMI Advisor: https://docs.sw.siemens.com/documentation/external/PL20221117716122093/en-US/nx_help/nx/2306/nx_help/en-US/mbd/index.html (retrieved 9 October 2026)
  • NXOpen .NET Reference Guide 2312, NXOpen.Annotations.Pmi: https://docs.sw.siemens.com/documentation/external/PL20230425446868577/en-US/custom_api/nxopen_net/a34650.html, and NXOpen Python Reference Guide 2312, NXOpen.Annotations.Annotation: https://docs.sw.siemens.com/documentation/external/PL20230425446868577/en-US/custom_api/nxopen_python_ref/a07494.html (retrieved 9 October 2026)
  • Siemens NX Manufacturing blog, “Streamlining machining and quality inspection operations using PMI” (14 July 2021): https://blogs.sw.siemens.com/nx-manufacturing/streamlining-machining-and-quality-inspection-operations-using-pmi/ (retrieved 9 October 2026)
  • Siemens Designcenter blog, “What’s New in NX, NX Inspector and MBD” (8 May 2025, December 2024 release): https://blogs.sw.siemens.com/designcenter/whats-new-in-nx-nx-inspector-and-mbd/ (retrieved 9 October 2026)
  • Siemens Designcenter blog, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 9 October 2026)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612, 31 August to 25 September 2026): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 9 October 2026)
  • NIST, STEP File Analyzer and Viewer (SFA), GitHub repository and release notes for version 5.51: https://github.com/usnistgov/SFA (retrieved 9 October 2026)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.