Contacts
Get in touch
Close

Contacts

Romania, Cluj-Napoca – 400157
Str. Ploiești Nr. 9

Romania, Vama – 447350
Str. Fermei Nr. 14

+40 774 463 429

info@inteliscience.net

NX Onboarding: A 30/60/90-Day Plan for New Designers (2026)

NX Onboarding: The Short Version

NX onboarding is the structured path from a new design engineer’s first Siemens NX login to independent, released work. A 30/60/90-day plan covers company standards and templates, real tasks under review, then owned work packages. inteliScience, a Siemens NX specialist in Cluj-Napoca, trains new hires on your own parts. Day-90 goal: releases that pass review in one loop.

Phase Goal NX focus Finish line
Before day oneA seat that matches the teamThe team’s NX release, company templates, site customer defaults, a Teamcenter training project, a named buddyThe new hire creates a part from the company template on the first morning
Days 1 to 30NX the way your company uses itBasics course, templates, modeling guideline, drafting standard, check-in and release flowOne released part and its drawing rebuilt from scratch, reviewed, not released
Days 31 to 60Real tasks under reviewDrawing revisions, part variants, simple change ordersReview findings shift from standards errors to product questions
Days 61 to 90Work of their ownAssemblies and interfaces, release in Teamcenter, manufacturing and supplier knowledgeA small work package released after one review loop, skills review done

The Problem: NX Onboarding Happens at the Senior’s Desk

In many design teams, NX onboarding is not a plan but a chair next to a senior. The new designer gets a login, a few old project parts to copy and a standing invitation to ask. NX habits then come from whoever answers. That worked while seniors had time. With the retirement wave, it ties the scarcest person in the team to a help desk.

The demographics are not subtle. Germany’s statistics office counted 12.9 million people in the labor force who will pass the statutory retirement age by 2036, almost 30% of the 2021 labor force, while the 15 to 24 age group held only 8.4 million (Destatis, 2022). For technical jobs, the Cologne Institute for Economic Research counted around 133,900 unfilled STEM vacancies in March 2026, with mechanical and automotive engineering among the shortage areas, and estimates that retirements could leave around 138,600 fewer STEM workers available by 2034 (Digital Skills and Jobs Platform, June 2026).

So the people who know why your housings are modeled the way they are will leave, and their successors are harder to find. Many arrive from another CAD system or straight from university.

Every question a successor asks costs senior time. In a work-sampling study, 78 design engineers logged their current task once an hour for 20 working days. Acquiring and providing information took 55.75% of their working time, and they spent as much time searching for information from other people as from documents and other non-human sources (Robinson, 2010). When the source was a person, more of that time went into problem solving and decision making. A senior’s answer is worth a lot, which is exactly why it should be written down once instead of given ten times.

Our position: onboarding a new NX designer is a 90-day project with an owner, a plan and a finish line per phase. It is also the best occasion you will get to capture what your seniors know, because someone new is asking the right questions anyway.

Before Day One: An NX Seat That Matches the Team

Prepare four things before the new designer arrives: an NX seat on the team’s release with the company templates and site customer defaults, access to a Teamcenter training project, a package of reference parts, and a buddy with reserved time. A first morning spent waiting for a license or a login tells the newcomer that your standards are optional.

The NX seat

Install the release your team works in, not the newest one. Siemens ships two NX releases a year. The current one, Designcenter 2606, arrived in June 2026 and renamed Designcenter NX to Designcenter (Siemens Designcenter blog, 23 June 2026), and Designcenter 2612 already went through Siemens’ Early Access Program from 31 August to 25 September 2026 (Siemens). Many teams stay one or two releases behind for good reasons, such as in-house tools tested on a specific version. The newcomer should learn on exactly the menus and dialogs they will work in.

Then add the company layer: the template set in File New, the site and group customer defaults, and a company role that shows the commands your standard uses. If File New still lists thirty templates, half of them in inches, fix that before the next hire; our guide to NX templates and start parts shows how. Site and group defaults live in nx_site.dpv and nx_group.dpv, inside a startup subfolder of the directories that UGII_SITE_DIR and UGII_GROUP_DIR point to (Swoosh Technologies). The journal below checks in a minute whether a new seat actually reads them:

# Day-one seat check for a new NX user: does this seat read the team's
# site and group customer defaults? Python journal on the public NXOpen API.
# Play it from Tools > Automation > Journal > Play.
import os

import NXOpen

# Customer defaults levels and the file NX expects in each "startup" folder.
LEVELS = [
    ("UGII_SITE_DIR", "nx_site.dpv"),
    ("UGII_GROUP_DIR", "nx_group.dpv"),
]


def main():
    lw = NXOpen.Session.GetSession().ListingWindow
    lw.Open()
    problems = 0
    for variable, dpv_file in LEVELS:
        folder = os.environ.get(variable, "")
        found = bool(folder) and os.path.isfile(os.path.join(folder, "startup", dpv_file))
        if not found:
            problems += 1
        lw.WriteLine(("OK    " if found else "FIX   ") + variable + " = " + (folder or "(not set)"))
    user_file = os.environ.get("UGII_LOCAL_USER_DEFAULTS", "(NX default location)")
    lw.WriteLine("INFO  user defaults file: " + user_file)
    if problems:
        lw.WriteLine(str(problems) + " setting(s) for the CAD admin to fix before day two.")
    else:
        lw.WriteLine("Seat reads the team's customer defaults.")


if __name__ == "__main__":
    main()

Run it on the first morning, together with the CAD admin. A seat that falls back to the shipped defaults produces parts that look right and fail review a month later.

Data access and reference parts

Give the newcomer a Teamcenter account with rights in a training project or sandbox, so that no exercise ends up in a released revision. Then collect five to ten released parts, assemblies and drawings that show “done right” in your company, plus one or two that show the problems you see most. These reference parts are the curriculum for the next 90 days.

A buddy with reserved time

Name the buddy before the start date and block the hours in the project plan. The mentoring section below has the planning values.

Days 1 to 30: Learn NX the Way Your Company Uses It

The first month teaches NX with your company layer on top. Start with a short basics course, then templates, modeling guideline, drafting standard and the Teamcenter release flow, all practiced on your reference parts. The finish line is one released part and its drawing, rebuilt from scratch and reviewed by the buddy, but not released.

For designers new to NX, a basics course covers sketching, part modeling, assemblies and drawings. Our NX CAD training for new designers covers those topics, can include work on your own project parts, and is given by NX engineers from our team who work in NX projects themselves. Designers who already know another 3D CAD system need fewer commands and more unlearning. For them, weeks two to four matter more than the course.

  1. Week 1: course and orientation. The basics course on the new seat, then a tour of where things live: templates, standards documents, reference parts, Teamcenter folders and the people to ask for what.
  2. Week 2: the modeling guideline on real parts. Rebuild one reference part from an empty template, then compare the feature tree with the original, side by side with the buddy. The differences are the lesson. If your guideline is a long PDF from three releases ago, write a shorter set of modeling rules before the next hire starts.
  3. Week 3: drawings to your standard. Derive the drawing of the rebuilt part on the company drawing template, with the title block filled from attributes and dimensions and tolerances the way your checker expects them.
  4. Week 4: the release flow. Check-in, revisions, where-used and the release workflow in the training project, then one review against the real checklist.

On-site or online? For new hires we recommend an on-site course at the start and online follow-ups once daily work raises questions, the split we explain in our comparison of NX training online and on-site. Either way, keep the group at six or fewer.

We’d advise against putting a new designer on project work in week one “to learn on the job”. The first parts someone builds tend to become their default, and in week one the only default available is the neighbor’s.

Days 31 to 60: Real Tasks, Reviewed Against a Checklist

In month two the newcomer works on real tasks with low risk and a fast review: drawing revisions, variants of existing parts, simple change orders. Every task goes through review with a written checklist, and the buddy notes what each finding is about. When standards errors give way to questions about the product, the onboarding is on track.

Task Fit for month two What it teaches
Drawing revision after a released changeYesDrafting standard, revisions, the change process
Variant of an existing part or part family memberYesReading someone else’s feature tree and design intent
Simple change order on a released partYesWhere-used, release workflow, talking to manufacturing
Bringing a legacy part up to the current standardYes, with a time boxGuideline, layers, attributes, reference sets
New top-level assembly or skeleton model with WAVE linksNot yetInterface and link rules belong to month three
Customer-critical part on a tight deadlineNoPressure teaches shortcuts, not standards

Count review findings by category, not only by number. Three categories are enough: standards (template, layers, attributes, title block), modeling (sketch constraints, feature order, references) and product (tolerances, manufacturability, materials). Standards findings should disappear first. If they keep coming back in week eight, look at the template or the guideline before you look at the new hire.

If your team runs Check-Mate profiles, the newcomer runs them before every review. The reviewer then spends the time on product questions, which is where the senior’s knowledge is actually needed.

Our clear recommendation: real tasks from week five, not a second month of exercises. An exercise cannot teach what a change order teaches about your products, your release process and the colleagues downstream.

Days 61 to 90: A Work Package of Their Own

Month three hands over one small work package end to end: a part or subassembly with its drawings, through review and release in Teamcenter. Alongside it, the new designer learns what no NX course covers: why your products look the way they do, from manufacturing, suppliers and the seniors who made the decisions.

Assemblies and interfaces come now. Reference sets, the WAVE rules from your guideline and the way your team builds top-down structures, if it does, all need a designer who already models cleanly. Send the newcomer to the shop floor when their first part is machined or assembled, and to one supplier conversation. An afternoon at the machine explains a tolerance faster than any review comment.

The 90-day skills review

Close the plan with a review against what the role requires, not against the course agenda. One matrix per role is enough:

Topic Day 30 Day 60 Day 90
Templates, layers, attributesApplies with reviewApplies aloneExplains it to the next hire
Sketching and part modeling to the guidelineApplies with reviewApplies aloneApplies alone
Drawings to the company standardKnows where it isApplies with reviewApplies alone
Teamcenter check-in, revisions, releaseKnows where it isApplies with reviewApplies alone
Assemblies, reference sets, WAVE rulesNot yetKnows where it isApplies with review
Product and manufacturing knowledgeNot yetAsks the right questionsApplies with review

Gaps at day 90 go into a training plan, not into a verdict. When several designers start at once, or onboarding stalls at the same point every time, the training-needs module of our NX Engineering Assessment reviews NX skills per role, the NX functions your team does not use yet and how new designers are onboarded, as part of a one-week, €4,900 fixed-price review.

A 30/60/90 plan on paper is the POC. What NX onboarding needs in production: a seat that matches your team, training on your own parts and templates, a buddy with reserved time, review checklists, and the seniors’ knowledge written down before they leave. We train new designers in-house or live online, in groups of up to six participants: Siemens NX training on your own parts.

Mentoring: Budget the Senior’s Time, Then Protect It

A buddy without reserved time turns into an interruption for both sides. Plan the mentor’s hours as explicitly as the newcomer’s: most in month one, less after that, written into the project plan. Spread topics over several seniors, so the onboarding does not depend on one calendar and the knowledge does not come from one head.

Our planning values are about an hour a day in month one, for a short morning check-in and reviews at the screen, then two to three hours a week in month two and one to two hours a week in month three. They are planning values, not measurements. They drop when templates and guideline are in good shape, because every rule written down is a question nobody has to answer.

Review at the screen together instead of redlining alone, so the reason arrives with the correction. A shared questions log helps more than people expect: the newcomer writes down every question and its answer, and after 90 days you have the onboarding FAQ for the next hire. Route topics to the right person, too. CAM questions go to the CAM programmer, Teamcenter questions to the admin, product questions to the senior who owns that product.

We’d advise against making your most senior designer the only mentor. That person has the most knowledge to capture and the least time, and a newcomer who only ever asks one person learns one person’s habits.

Capturing Senior Engineers’ Knowledge Before They Retire

Use the onboarding as the capture mechanism. Pair the newcomer with the senior who retires next, let the newcomer write and the senior correct, and capture reasons on real parts instead of in general lectures. Start about a year before the retirement date where you can, while the senior still has the time and the patience for it.

Handover documents written in the last two weeks miss what matters. Dorothy Leonard and Walter Swap describe the judgment of experienced experts as “deep smarts”, insight “based more on know-how than on facts” (Harvard Business Review, 2004). Know-how shows when someone explains a real part: why the housing has a separate machining model, why this bore gets a tighter tolerance than the general standard, which supplier cannot hold that radius.

What to capture

  1. Annotated reference parts. The senior walks through ten parts that show how your products are built, and the newcomer writes down the reasons.
  2. A decision log for the “why” questions that come up again and again: tolerances, materials, standard parts, supplier limits.
  3. Short screen recordings of the senior explaining tricky parts, five to fifteen minutes each, filed by product and kept internal because they show your geometry.
  4. The senior’s personal tooling: journals, NXOpen macros, roles, customer defaults and private templates on their own seat. When that workstation is wiped, tools that only ran there disappear with it.
  5. A contact map of who in manufacturing, purchasing or at which supplier knows what.
  6. The newcomer’s questions log from the mentoring phase, with every answer checked by the senior.

A register the newcomer writes and the senior signs off

Keep the captured knowledge in a register with one entry per question, not in one long document. The fields matter more than the tool:

# One entry of a knowledge capture register (illustrative example)
- id: KC-027
  question: "Why are cast housings modeled as a cast part plus a separate machined part?"
  answer: "Foundry and machining shop need different models; the cast part carries draft and allowance."
  answered_by: "Senior design engineer, housings"
  captured_by: "New designer, onboarding month 3"
  evidence: ["Reference part 4 with both bodies", "Walkthrough recording, 11 min"]
  becomes_rule: "Yes, candidate for the modeling guideline, chapter Interfaces"
  status: "confirmed by senior"
  reviewed: "2026-10"

Entries that turn out to be rules move into the modeling guideline or the template. Entries that stay judgment calls remain in the register, with a name attached.

Where AI helps, and where it does not

Once the register exists, an NX knowledge chatbot can answer “how do we do this here” from it, with cited sources, so follow-up questions stop landing on one senior. It does not replace the capture: an assistant can only answer from what someone wrote down. The same holds for Siemens’ own Copilot, which the June 2026 release describes as giving “instant answers grounded in Designcenter documentation and best practices”. The reasons behind your company’s parts are not in that documentation.


Frequently Asked Questions

How long does it take a new design engineer to become productive in Siemens NX?

There is no published benchmark; a structured plan aims at simple real tasks from the second month and a small work package of their own by the end of the third. The Siemens NX basics fit into a short course; following company standards takes the first month of guided practice, and product knowledge takes longer than either. Designers who already know another 3D CAD system get through the command phase faster but still need the company layer.

What should a 30-60-90 day onboarding plan for a CAD design engineer include?

A 30-60-90 day plan for a CAD design engineer should set one finish line per phase: company standards, templates and a reviewed practice part by day 30, real low-risk tasks under review by day 60, and a small work package released by day 90. It also names a mentor with reserved time, the reference parts to learn from and a skills review at the end. In Siemens NX the plan starts before day one, with a seat that uses the team’s templates and customer defaults.

How can engineering companies capture the knowledge of senior engineers before they retire?

The most reliable way is to capture knowledge on real work: pair the retiring engineer with a successor, walk through representative parts and record the reasons behind design decisions in a register that the successor writes and the senior checks. Handover documents written in the final weeks miss most of the know-how. Start about a year ahead where possible, and include the senior’s personal tools, such as NX journals, macros and customer defaults.

Siemens NX training course vs on-the-job learning: which works better for new design engineers?

Both, in that order: a short Siemens NX course for the commands, then structured on-the-job learning for the company’s standards and products. On-the-job learning alone copies the habits of whoever sits next to the new hire, and a course alone teaches generic NX without your templates. A course held on your own parts and templates closes part of that gap from the first day.

How much does Siemens NX training for new hires cost in 2026?

Published in-house rates in Germany reach about €2,000 per training day for a group of up to six, and live online offers start at €690 per day for a single participant (provider price lists, October 2026). inteliScience quotes in-house and live online courses after a short call, based on modules and group size. The larger cost of NX onboarding is the mentor’s time in the first three months, which belongs in the budget as well.


Next Step

New designers starting soon, or a senior retiring next year? Send us your templates, your modeling guideline and the start date. In a free 60-minute call, inteliScience’s NX trainers sketch a 90-day plan around your own parts and tell you which topics belong in a course and which belong with your mentor.

Plan your NX onboarding with our trainers



References

  1. Destatis (Federal Statistical Office of Germany), press release No. 330, 4 August 2022, on 12.9 million people in the labor force reaching statutory retirement age within 15 years (in German): https://www.destatis.de/DE/Presse/Pressemitteilungen/2022/08/PD22_330_13.html (retrieved 9 October 2026)
  2. Digital Skills and Jobs Platform, “STEM skills shortage: Germany persists, over 130,000 vacancies remained vacant in March 2026” (updated 15 June 2026), on the Spring 2026 STEM Report of the Cologne Institute for Economic Research: https://digital-skills-jobs.europa.eu/en/latest/news/stem-skills-shortage-germany-persists-over-130000-vacancies-remained-vacant-march-2026 (retrieved 9 October 2026)
  3. Robinson, M. A., “An empirical analysis of engineers’ information behaviors”, Journal of the American Society for Information Science and Technology 61(4), 640-658, 2010: https://doi.org/10.1002/asi.21290 (abstract retrieved via Crossref, 9 October 2026)
  4. Leonard, D., Swap, W., “Deep Smarts”, Harvard Business Review, September 2004: https://hbr.org/2004/09/deep-smarts (retrieved 9 October 2026)
  5. Siemens Designcenter blog, Jamie Tyler, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 9 October 2026)
  6. Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612): https://resources.sw.siemens.com/en-US/presentation-welcome-to-the-nx-early-access-program (retrieved 9 October 2026)
  7. Swoosh Technologies, “How to define the defaults level of Customer Defaults” (6 April 2023): https://www.swooshtech.com/2023/04/06/how-to-define-the-defaults-level-of-customer-defaults/ (retrieved 9 October 2026)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.