NX Customer Defaults: The Short Version

NX customer defaults are the starting values Siemens NX uses for new parts, dialogs and sessions, from units and drafting standards to assembly load options, stored in .dpv files at site, group and user level. inteliScience, a Siemens NX team in Cluj-Napoca, runs them as one locked, versioned site standard. Result: every workstation starts NX identically.

Level Defined by File NX reads Who should write it What belongs there
ShippedNothing to setDelivered with NX, read-onlySiemensFactory values
SiteUGII_SITE_DIRnx_site.dpv in the startup subfolderOne CAD administratorThe company standard and its locks
GroupUGII_GROUP_DIRnx_group.dpv in the startup subfolderThe administrator, on request of a departmentJustified deviations, for example for manufacturing
UserUGII_LOCAL_USER_DEFAULTSnx_user.dpv per userThe designerPersonal choices that are not locked

The Problem: Fifty Workstations, Fifty Versions of “Default”

Open File, Utilities, Customer Defaults on a workstation nobody has configured and the only writable level is User. Every designer who changes a value writes a personal nx_user.dpv, and from then on that seat behaves differently from the next one. Multiply by fifty seats and three years, and “the default” no longer exists.

The effects are rarely dramatic. They are expensive in small amounts: an assembly that loads a different reference set on one machine, a drawing with another arrow style, a part created from the Blank template in the wrong units, a Teamcenter save that behaves differently for one team. Each costs a support call or a review loop, and nobody connects it to a setting buried in a dialog with hundreds of tabs.

Customer defaults also decide what a part carries for life. Part settings come from the customer defaults when a part is created from the Blank template, are saved with that part and stay there. Changing the default later does not touch existing parts. Getting this under control is usually the first job when we take over NX administration for a design team.

How NX Customer Defaults Work: Levels, Inheritance and Locks

NX customer defaults work in four levels: Shipped, Site, Group and User. Each higher level passes its values down, and a lock on a higher level stops every lower level from changing that value. A site lock binds group and user, a group lock binds users, and users cannot lock anything at all.

You open the dialog with File, Utilities, Customer Defaults; no part needs to be open. The Defaults Level field at the top tells you where you are writing. Site, Group and User only appear when the matching environment variables are defined, and once any custom level exists, the Shipped level disappears from the list. Without write access to the current level, NX warns you at the first change and the OK and Apply buttons stay unavailable.

Three tools in the dialog do most of the administrative work:

  1. Find Default searches all applications for a string, so you do not have to know whether a setting lives under Gateway, Assemblies or Teamcenter Integration for NX.
  2. Manage Current Settings lists every value changed at the current level and lets you comment on it, delete the change, and import or export defaults files.
  3. The lock toggle next to each value, set at site or group level for everything your standards depend on.

Changes in the tabbed pages apply from the next NX session. Tell users to restart, or they will report that the new standard does not work.

Part settings and session settings behave differently

This distinction causes most of the confusion. A part setting, such as the drafting standard for new parts, is copied into a part created from the Blank template and then belongs to that part. Parts created from your own templates take their settings from the template, not from the defaults. A session setting, such as assembly load behavior, applies to everything you open after the next restart. Some session values can also be overridden by entries in UserPreferences.txt, which NX keeps per user and per functional release under %LOCALAPPDATA%\Siemens\.

Where the NX Customer Defaults File Lives

The NX customer defaults file of each level is a .dpv file named after product and level: nx_site.dpv, nx_group.dpv, nx_user.dpv. Site and group files sit in a startup subfolder of the directories that UGII_SITE_DIR and UGII_GROUP_DIR point to. The user file goes wherever UGII_LOCAL_USER_DEFAULTS points.

Since NX 3, Siemens wants these files changed through the dialog only, not in a text editor. That leaves the administrator two jobs: keep the site and group files in a controlled place, and make every workstation find them. One detail that trips people up: UGII_USER_PROFILE_DIR relocates many per-user files, including UserPreferences.txt, dialog memory and roles, but not the user customer defaults. Those follow their own variable.

Our clear recommendation: site defaults on a read-only share, written by one administrator account, with one folder per NX functional release. A share every designer can write to is just a user level with extra steps.

# Point an NX workstation at the company customer defaults.
# Run with administrator rights, or set the same variables by group policy.
$Release = "2606"
$Share   = "\\cadfs01\nx-standards\customer-defaults\$Release"

# Site level: one company standard, read-only for designers.
[Environment]::SetEnvironmentVariable("UGII_SITE_DIR", "$Share\site", "Machine")

# Group level: only for a department with a justified deviation.
[Environment]::SetEnvironmentVariable("UGII_GROUP_DIR", "$Share\group-manufacturing", "Machine")

# NX reads nx_site.dpv and nx_group.dpv from the startup subfolder.
foreach ($file in "$Share\site\startup\nx_site.dpv", "$Share\group-manufacturing\startup\nx_group.dpv") {
    if (-not (Test-Path $file)) { Write-Warning "Missing: $file" }
}

If people from different departments share workstations, set the group variable per user instead of per machine. The share itself stays simple: site\startup\nx_site.dpv, one group-\startup\nx_group.dpv per department, and a changelog next to them.

How to Export, Import and Reset NX Customer Defaults

To export NX customer defaults, open Manage Current Settings at the level you want and export the changed values to a .dpv file. To import, use Import Defaults in the same dialog. Resetting means deleting changes there, which returns each value to whatever the level above provides.

The buttons are easy. The details are where imports go wrong:

Task Where What to watch
Copy to another workstationManage Current Settings, export at the level you want to copyOnly the values changed at that level travel, not inherited ones
Document the standardManage Current Settings, Export All Defaults Data to SpreadsheetOne row per default with its values per level, good for reviews
ImportManage Current Settings, Import DefaultsNothing is saved until you click OK or Apply in the Customer Defaults dialog
Read the import resultThe Information windowTotals for imported, rejected (invalid or locked above), unchanged and unrecognized settings
Reset one valueManage Current Settings, delete the changeThe value falls back to the next higher level
Explain a valueManage Current Settings, Edit CommentThe comment shows as a tooltip next to the default

Two traps. Defaults with list values, such as the symbolic thread method, are not imported and have to be set in the dialog. And a value rejected because it is locked at a higher level is not an error; that is the lock doing its job. Search the Information window for “This value was invalid and was not imported” to find the real problems.

For a full reset of one user, close NX and rename that user’s nx_user.dpv. NX then starts again from the group, site and shipped values. Siemens’ support knowledge base also advises resetting dialog memory (Preferences, User Interface, Dialog and Precision, Reset Dialog Memory) before working with new defaults, because remembered dialog entries can hide the new values.

Managing NX Customer Defaults Across a Company

Manage NX customer defaults like a released standard: one owner, a short written spec of what is set and why, the site file under version control, a comment on every changed value, and locks on whatever your templates, drawings and Teamcenter integration depend on. Everything else stays free for users.

What to lock is a judgment call. We lock the units for new parts, the drafting and PMI standard, the Teamcenter integration settings that affect saving and naming, and the assembly load options that decide what a large assembly pulls into memory. Colors, UI layout and most selection preferences stay open; locking taste only produces workarounds. We’d also advise against a group level per project. Groups are for stable differences between departments, design versus manufacturing for instance, not for the wishes of the current program.

Then check what the workstations actually do. The journal below uses the general NXOpen Python API (the OptionsManager class) to list every default that is set at site, group or user level on a workstation, which ones are locked, and where a user value differs from the site value. Run it on a handful of seats and drift becomes a CSV instead of a feeling.

# Customer defaults audit: which defaults are set at site, group and user level,
# which are locked, and where a user value differs from the site value.
# NXOpen Python, general API. Batch example:
#   run_journal.exe defaults_audit.py -args C:\nx-audit\defaults_audit.csv
import csv
import sys

import NXOpen
import NXOpen.Options as Opt

LEVELS = [("site", Opt.LevelType.Site), ("group", Opt.LevelType.Group), ("user", Opt.LevelType.User)]


def read(manager, name, *level):
    """Value as text; the effective session value if no level is given."""
    kind = manager.GetOptionType(name)
    if kind == Opt.OptionType.Int:
        return str(manager.GetIntValue(name, *level))
    if kind == Opt.OptionType.Real:
        return str(manager.GetRealValue(name, *level))
    if kind == Opt.OptionType.Logical:
        return str(manager.GetLogicalValue(name, *level))
    if kind == Opt.OptionType.String:
        return manager.GetStringValue(name, *level)
    if kind == Opt.OptionType.Utf8string:
        return manager.GetUtf8stringValue(name, *level)
    if kind == Opt.OptionType.StringList:
        return ";".join(manager.GetStringListValue(name, *level))
    return "(list type, not read)"


def check(test, name, level):
    try:
        return test(name, level)
    except NXOpen.NXException:
        return False  # level not defined on this workstation


def main(out_csv):
    manager = NXOpen.Session.GetSession().OptionsManager
    with open(out_csv, "w", newline="", encoding="utf-8") as f:
        writer = csv.writer(f)
        writer.writerow(["default", "effective", "set_at", "locked_at", "site", "user", "user_differs"])
        for name in manager.GetAllOptions():
            set_at = [label for label, level in LEVELS if check(manager.IsValueSet, name, level)]
            if not set_at:
                continue  # still the shipped value
            locked_at = [label for label, level in LEVELS[:2] if check(manager.IsValueLocked, name, level)]
            site = read(manager, name, Opt.LevelType.Site) if "site" in set_at else ""
            user = read(manager, name, Opt.LevelType.User) if "user" in set_at else ""
            writer.writerow([name, read(manager, name), "/".join(set_at), "/".join(locked_at),
                             site, user, "yes" if site and user and site != user else ""])


if __name__ == "__main__":
    main(sys.argv[-1])  # the value passed after -args

The first column shows internal option names, not dialog labels. Sort by user_differs: those rows are the seats that no longer follow your standard. If you already check models against company rules, the same discipline belongs on the settings that create them; our article on measuring Siemens NX CAD quality covers the model side.

A clean site file on one share is a prototype. What’s missing for production: a written spec your methods team owns, the same defaults on every seat and per department, locks that match your templates and Teamcenter setup, an audit of the seats that drifted, and a plan for the next release. We set this up and keep it current as part of our NX administration services for Siemens NX teams, delivered by our engineers in Cluj-Napoca.

Since the June 2026 release (Designcenter 2606), Live Share sessions synchronize customer defaults automatically between participants, according to Siemens’ release announcement. Useful, and it raises the stakes: whatever your site file says now also shapes shared editing sessions.

NX Customer Defaults Across Upgrades

Every NX functional release installs into its own directory, and your customer defaults have to move with you. Siemens’ procedure: import the previous release’s .dpv file per level with Import Defaults, read the summary, then review the defaults that are new or changed in the release before you lock anything.

The import builds a new .dpv file with your old values applied to matching defaults in the new release. Settings that no longer exist are reported as not recognized, values that are no longer valid as rejected. Next, Find Default with the release number: typing a version such as 2606 lists the defaults that are new or changed in that release, and a plus sign (2512+) includes the changes from its monthly updates. Siemens’ documentation shows the same search with older numbers such as 1953.

Our routine per functional release:

  1. Copy the site and group folders into a new release folder (for example ...\customer-defaults\2606) and import there. The old release keeps its own files during parallel operation.
  2. Import site first, then group, then a few user files, and attach the Information window output to the change ticket.
  3. Run Find Default for the new release number and decide per new default: accept, change or lock.
  4. Run the audit journal on the same workstation in the old and the new release and compare both CSV files.
  5. Point a pilot group at the new folder for a few weeks, then switch everyone.

Siemens ships two functional releases a year, so this is a twice-yearly routine, not a project. Designcenter 2606 arrived on 23 June 2026, and Siemens opened the early access program for Designcenter 2612 on 31 August 2026. Teams that skip a release import from an older file; the procedure is the same, the summary just gets longer. Defaults are only one item on that list, next to templates, NXOpen programs, CAM posts and Teamcenter, which our NX release upgrade service handles as one package.

Frequently Asked Questions

Where are NX customer defaults stored?

NX customer defaults are stored in .dpv files, one per level: nx_site.dpv and nx_group.dpv in the startup subfolder of the directories set by the UGII_SITE_DIR and UGII_GROUP_DIR environment variables, and nx_user.dpv where UGII_LOCAL_USER_DEFAULTS points. If none of the levels is defined, NX runs on the read-only Shipped level. Other Siemens products follow the same naming pattern, for example simcenter_user.dpv.

How do you export and import NX customer defaults to another computer?

In Siemens NX, open File, Utilities, Customer Defaults, choose the level, open Manage Current Settings and export the changed values to a .dpv file. On the target computer, use Import Defaults in the same dialog, check the summary in the Information window and click OK or Apply to save. List-valued defaults are not imported and have to be set by hand.

Can NX customer defaults be locked so users cannot change them?

Yes. A value locked at site level cannot be changed at group or user level, and a value locked at group level cannot be changed by users; there are no locks at user level. Administrators need write access to the site or group directory and designers should only have read access there, otherwise the lock is a convention rather than a control.

NX customer defaults vs user preferences: what is the difference?

Customer defaults are the starting values that Siemens NX applies to new parts created from the Blank template and to new sessions, managed per level and lockable by an administrator. Preferences change the current part or session directly, and some session preferences are saved per user in UserPreferences.txt, where they can override the matching default. If a user sees a value that contradicts the site default, check UserPreferences.txt and the part’s own settings first.

How much effort does it take to standardize NX customer defaults for a design team?

For one site and one functional release, the defaults themselves take days, not weeks: an inventory of today’s user files, a decision per relevant default, a locked site file and a test on a few seats. The effort grows with every department that needs its own group level, with Teamcenter integration settings and with the number of workstations to roll out. inteliScience offers a free first call with an NX engineer and a one-week NX Engineering Assessment for €4,900 fixed that reviews customer defaults together with templates and the rest of the NX setup.


Next Step

Bring one site file and two user files from your team. In a free 60-minute call, inteliScience’s Siemens NX engineers from Cluj-Napoca show what is set where, what has drifted and what a locked, versioned standard would change, under NDA. Talk to an NX engineer about your customer defaults



References

  • Siemens Designcenter blog, Jamie Tyler, “Designcenter is for everyone, June 2026 release” (23 June 2026, Live Share synchronizes customer defaults): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 10 September 2026)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612, virtual week from 31 August 2026): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 10 September 2026)
  • Siemens Support Center knowledge base, “How to find out the new and the modified customer defaults settings specific to the upgraded version?” (PL8665238, login required): https://support.sw.siemens.com/en-US/okba/PL8665238/How-to-find-out-the-new-and-the-modified-customer-defaults-settings-specific-to-the-upgraded-version/index.html (retrieved 10 September 2026)
  • Siemens Support Center knowledge base, “Moving customer defaults and roles in NX” (PL8002562, login required): https://support.sw.siemens.com/en-US/okba/PL8002562/Moving-customer-defaults-and-roles-in-NX/index.html (retrieved 10 September 2026)
  • Siemens NX help, Customer Defaults topics (levels of customer defaults, Manage Current Settings, migrating customer defaults, user-specific settings file) and NXOpen Python reference for NXOpen.Options.OptionsManager, checked against the NX 2506 documentation set

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.