MBD Supplier Data Package: What Goes Inside (2026)

MBD Supplier Data Package: The Short Version

An MBD supplier data package replaces the drawing in a supplier’s inbox: STEP AP242 with semantic PMI for software, a 3D PDF or JT for people, and a manifest fixing revision and authority. inteliScience’s Siemens NX engineers specify and test it per supplier. Without it, suppliers rebuild models: 52.5 hours for one NIST test case.

Item File Who uses it When it goes in
Definition for softwareSTEP AP242 with semantic PMI and validation propertiesCAM and CMM programming, suppliers on other CAD systemsAlways, once the model is the authority
View for people3D PDF, or JT plus PDF, published from the same NX revisionEstimating, shop floor, incoming inspectionAlways, but never as the only file for programming
SheetLimited-dimension drawing as PDFAnyone whose procedure still requires a sheetWhile the part’s classification code includes a drawing
Native modelNX part with expressions and internal logic removedDevelopment partners who work in NXOnly by agreement
Transmittal and manifestOne page, plus a file list with checksumsSupplier quality, your own audit trailAlways
Validation evidenceValidation property values and a check report of the STEP fileSupplier quality, first article inspectionFirst delivery to each supplier, then with every revision

The Problem: “Just Send Them the STEP” Is Not a Data Package

Most MBD programs fix authoring first and treat the hand-over as an export button. That is where they break. A STEP file without semantic PMI, a 3D PDF the supplier’s reader cannot display, or one file a revision behind the others turns the model back into a drawing problem, except that now the supplier has to solve it.

The old hand-over is well documented. NIST researchers summarized it in 2016: the OEM provides design data to the supplier as 2D drawings, sometimes with a 3D shape-geometry model in STEP AP203. AP242 changed what can travel, “a standards-based model with embedded PMI”, and the same study set out to find the gaps in tools, standards and processes that keep supply chains from using it (Trainer, Hedberg et al., MSEC2016). Another NIST study from 2016 measured the cost of the old way: the drawing-based supplier rebuilt the 3D model from the drawing, which alone took 52.5 hours in the first of three test cases (Hedberg et al., 2016).

The UK National Physical Laboratory is blunter. Its report on MBD supply chain integration calls supplier access “the most vulnerable point where data loss is expected to occur” (NPL Report MS 46, February 2023). Suppliers without the original software convert your files into formats they can work with, and every conversion can drop something: a tolerance, a datum reference, a view.

This guide covers one deliverable. Which standard to follow, how to set up NX and how to sort suppliers into tiers is the subject of our roadmap for an MBD implementation in five stages. Here we zoom into the package itself: what goes inside, what a supplier without NX can open, and how you check it before it leaves. The opposite direction, supplier files coming into NX, has its own checks in our guide to NX STEP import.


What Goes Inside an MBD Supplier Data Package

Four items go to every supplier: a definition file for software, a viewable for people, a transmittal with a manifest, and evidence that the export was checked. A limited-dimension drawing and the native NX part are added only where procedures or the collaboration require them. Every file comes from one released revision, or the package is not released.

The definition file: STEP AP242 with semantic PMI

STEP AP242 is the file that lets the supplier’s software do work. The CAx Interoperability Forum states that semantic representation of PMI “is supported by AP242 only” (CAx-IF PMI Recommended Practices 4.1, June 2024), so AP203 and AP214 exports can carry pictures of tolerances at best.

AP242 in the header is no guarantee, though. A tessellated export can carry graphical PMI only, and a CMM programmer cannot use a picture. How to tell the two apart in an existing file is shown in our check for semantic versus graphical PMI. Export both: semantic PMI for software, linked to its presentation so that people see the same callouts in a viewer. And switch on validation properties, which we come back to below.

Why the effort pays: on a high-volume powertrain line documented by Siemens, the PMI-based approach “has saved 50 percent or more of typical CMM programming time” (Siemens NX Manufacturing blog, July 2021). That saving only reaches the supplier if the PMI they receive is semantic.

The viewable: 3D PDF or JT plus PDF

Estimators, machinists and inspectors need to read the part, not process it. In NX, the Publish Technical Data Package command “gives you the option of either 3D PDF or JT+PDF file formats”, includes the PMI and the 3D model for users without NX, and follows a template you can customize (Siemens Designcenter blog, February 2026). The JT+PDF route attaches a JT file to an ordinary PDF (ISO 32000-1, PDF 1.7), and Siemens’ free JT2Go viewer links references in the PDF to PMI, geometry, model views and assembly structure in the JT (Siemens white paper, 2017).

Our clear recommendation: build the TDP template once, with the title block data, the revision and the authority sentence on the first page. Then every viewable that leaves NX says which file governs, even when someone forwards it without the rest of the package.

The sheet: a limited-dimension drawing, only where still needed

If a supplier’s procedures or a customer contract still require a sheet, send a limited-dimension drawing derived from the model, not a fully dimensioned one. Write the ISO 16792 classification code into the transmittal. Code 3 means the annotated model and a simplified drawing are used together; code 5 means no drawing exists. A supplier who knows the code knows which artifact wins in a dispute.

The native NX part: by agreement only

We’d advise against sending native NX parts by default. A native part carries expressions, feature history and design logic you may not want to share, and a supplier on an older NX release cannot open a part saved in a newer one. For development partners who work in NX it is still the richest format, so send it there, but strip what should stay in-house first. Our team has built exactly that step for NX parts going to partners, so the geometry travels and the know-how stays.

The transmittal and manifest

The transmittal is one page that makes the package unambiguous: part number and revision, standard and edition, classification code, the authority sentence, export settings, what it supersedes and who answers questions. The manifest lists every file with its size and checksum. A starting point, to be adapted to your standard and checked by whoever signs your supplier contracts:

MBD SUPPLIER DATA PACKAGE - TRANSMITTAL
Part / revision     : 4711-100 / C
Definition          : ISO 16792:2021, classification code 3 (annotated model + simplified drawing)
Authority           : 4711-100_C.stp is the authority for all geometry not dimensioned
                      on drawing 4711-100_C_ldd.pdf. Model and drawing share revision C.
Viewables           : 4711-100_C_3d.pdf is for reading only. Do not program from it.
Files               : see manifest.csv (name, size, SHA-256 per file)
Export              : Designcenter (NX) 2606, AP242 export settings file v3
Validation          : geometric and PMI validation properties in the STEP file,
                      check report attached
Supersedes          : revision B; all files of revision B are withdrawn
Questions           : <name, e-mail>, answered within two working days

Validation evidence

The last item is proof. Attach the check report of the STEP file and record the expected validation property values with the package, so the supplier can compare what their system computes on import with what yours wrote on export.


What Suppliers Without NX Can Actually Read

More than most design teams assume, and less than most MBD slides promise. Every role at a supplier can view an MBD package with free software. Whether their software can use the PMI to program a machine or a CMM depends on the CAM and metrology systems they own, so ask for product names and versions, not for “MBD, yes or no”.

Format Exact geometry PMI that software can process Free way to open it Use it for
STEP AP242 (ISO 10303-242)YesYes, if exported as semantic PMINIST STEP File Analyzer and Viewer (Windows)CAM and CMM programming, other CAD systems
JT (ISO 14306)Tessellated; exact geometry optionalDepends on the receiving softwareSiemens JT2Go (desktop, iOS, Android)Viewing, design reviews, partners on Teamcenter
3D PDFDepends on the export; not meant for programmingNo, made for peopleA PDF reader that renders embedded 3D contentQuoting, shop floor, incoming inspection
QIF (ISO 23952:2020)Part geometry for inspectionYes, in metrology software that supports QIFNot a viewing formatCMM planning and inspection results
Native NX partYesYes, in NXNone; needs NX of the same or a newer releaseDevelopment partners working in NX

The free tools are real. NIST’s STEP File Viewer “supports parts, assemblies, dimensions, tolerances, and more” (NIST SFA), and Siemens describes JT2Go as its “free viewer for JT and Parasolid XT data” (Siemens JT2Go). JT itself became ISO 14306 in December 2012, and QIF, maintained by the Digital Metrology Standards Consortium, was published as ISO 23952:2020 (QIF Standards).

Where it gets thin is role by role:

  • Estimators and purchasing work from the 3D PDF. A 3D PDF needs a reader that renders the embedded 3D content, and many browser and mobile PDF viewers show a flat page or an empty frame instead. Some readers also ask the user to enable 3D content first.
  • CAM programmers import the STEP AP242 file. The geometry is the easy part; whether their CAM system uses the tolerances, for example to pick a reamer for an H7 bore, depends on the product. Siemens’ own standards paper advises checking “that the destination system supports the required content before embarking upon AP242-based exchange”.
  • CMM programmers benefit most from semantic PMI, in AP242 or, where both sides support it, QIF. On the NX side, NX Inspector outputs QIF and PLMXML. Without either, someone keys every tolerance in again from the 3D PDF, which is the expensive path MBD was meant to remove.
  • Incoming inspection and the shop floor read the 3D PDF on a screen or the limited-dimension drawing on paper.

Before the first package goes to a supplier, ask five questions. The answers decide the package more than any internal standard does:

  1. Which CAM system and version programs your machines, and does it import PMI from STEP AP242?
  2. Which CMM programming software do you use, and does it import semantic PMI from AP242 or QIF?
  3. Which PDF reader do estimators and inspectors use, and on which devices?
  4. Do you convert incoming CAD files before use, and into which format?
  5. Who checks incoming CAD data at your company, and against what?

The NPL report adds a point many OEMs skip: effort should also go into training and educating less digitally literate suppliers. A supplier who cannot open the package is not refusing MBD. Usually nobody has shown them how.


Validate Before You Send: Five Checks on Every Package

Check the files the supplier will receive, not the NX model they came from. A model can be perfect in NX and still leave with graphics-only PMI, a missing model view or one file a revision behind. Five checks, run in this order, catch these before the supplier does, and four of them run without NX.

  1. PMI rules in NX, before export. PMI Advisor with your company checks, or Check-Mate if you already run it, catches missing datums and unattached tolerances while they are still cheap to fix.
  2. Semantic PMI in the exported STEP file. Open the export in a second application. NIST’s free STEP File Analyzer and Viewer (SFA) reports semantic PMI, graphic PMI and validation properties against the CAx-IF recommended practices. Version 5.51 was released on 14 September 2026, after 5.50 (20 August 2026) added AP242 XML files with assembly structure to the viewer. New releases now appear only in the SFA repository on GitHub, which had 198 stars on 9 October 2026. It needs Windows and Excel, and a command-line version suits batch runs.
  3. Validation properties as checksums. Geometric validation properties (volume, surface area, centroid) are computed by the sending CAD system on export, where the export settings switch them on, and recomputed by the receiving system on import. The CAx-IF lists 0.5 percent for volume and surface area, and 0.02 mm plus a 0.1 percent ratio for the centroid of parts larger than 20 mm, as well-proven industry thresholds (CAx-IF, version 4.6, April 2023). PMI validation properties do the same for annotations: the number of semantic PMI elements per part and per type, the number of annotations and the number of views, intended “to act as a checksum”.
  4. Viewables in the supplier’s reader. Open the 3D PDF or the JT in the reader the supplier named in question 3. Every model view must be there, every callout legible, and the title block data on the first page.
  5. Package consistency. Same part number and revision on every file, all required formats present, a checksum for each file in the manifest. That one is pure bookkeeping, so a script does it.

A package check you can run today

This script needs plain Python 3 and no CAD system. It checks that each file belongs to the part and revision being released, that the required formats are present, that every STEP file is AP242 and carries geometric and PMI validation properties, and it writes the manifest with SHA-256 checksums.

# package_check.py: is an MBD supplier data package complete and consistent?
# Plain Python 3, no CAD system needed.
# Usage: python package_check.py <package folder> <part number> <revision>
# Naming rule: <part>_<rev>[_<suffix>].<ext>, e.g. 4711-100_C.stp, 4711-100_C_3d.pdf
import csv
import hashlib
import re
import sys
from pathlib import Path

REQUIRED = {".stp": "STEP AP242", ".pdf": "3D PDF"}  # adapt per supplier tier, e.g. ".jt"

folder, part, rev = Path(sys.argv[1]), sys.argv[2], sys.argv[3]
name_rule = re.compile(rf"{re.escape(part)}_{re.escape(rev)}(_\w+)?\.\w+", re.I)
files = sorted(f for f in folder.iterdir() if f.is_file() and f.name != "manifest.csv")
errors, rows = [], []

for ext, label in REQUIRED.items():
    if not any(f.suffix.lower() == ext for f in files):
        errors.append(f"missing {label} ({ext})")

for f in files:
    if not name_rule.fullmatch(f.name):
        errors.append(f"{f.name}: not part {part} revision {rev}")
    schema, props = "", ""
    if f.suffix.lower() in (".stp", ".step"):
        text = f.read_text(encoding="latin-1").upper()
        found = re.search(r"FILE_SCHEMA\s*\(\s*\(\s*'([A-Z0-9_]+)", text)
        schema = found.group(1) if found else "not found"
        geo = text.count("'GEOMETRIC VALIDATION PROPERTY'")
        pmi = text.count("'PMI VALIDATION PROPERTY'")
        props = f"geometric={geo} pmi={pmi}"
        if not schema.startswith("AP242"):
            errors.append(f"{f.name}: schema {schema}, not AP242")
        if geo == 0 or pmi == 0:
            errors.append(f"{f.name}: validation properties missing ({props})")
    sha = hashlib.sha256(f.read_bytes()).hexdigest()
    rows.append([f.name, f.stat().st_size, sha, schema, props])

with open(folder / "manifest.csv", "w", newline="") as out:
    writer = csv.writer(out)
    writer.writerow(["file", "bytes", "sha256", "step_schema", "validation_properties"])
    writer.writerows(rows)

print("\n".join(errors) or f"OK: {len(rows)} files, manifest.csv written")
sys.exit(1 if errors else 0)

We tested it on two folders. A complete revision C package returned OK: 3 files, manifest.csv written. A folder with an AP214 file and a leftover revision B drawing returned three findings: the drawing does not belong to revision C, the STEP schema is AUTOMOTIVE_DESIGN instead of AP242, and the file has geometric but no PMI validation properties. Not every translator writes PMI validation properties. If yours does not, the script says so on purpose; take the PMI counts from the SFA report into the transmittal instead.

The round trip for the first delivery

For the first package to each supplier, close the loop. The NPL report recommends that suppliers who convert files send them back, so the originator can check for data loss before the converted file is used, “akin to a 2-factor authentication process”, with the tolerances for data loss agreed in advance. We would run that round trip on the first delivery to every supplier and again after either side changes software.

You do not have to start with production data. The NIST CAD models with PMI, which the CAx-IF uses to test AP242 implementations, are public, and a set of NIST PMI STEP files ships in the SFA release folder. NIST notes that these test cases are not meant as best practice for applying GD&T, only as valid presentations of it, which is exactly what a format test needs.

This checks one package on one workstation. What’s missing for production: an AP242 export settings file under version control, a TDP template with your authority sentence, a package specification per supplier tier, and suppliers who have confirmed they can read what you send. Our fixed-price MBD Readiness Assessment (€4,900, one week, five of your parts) exports your sample parts as STEP AP242, JT and 3D PDF, checks what arrives and ends with a transition roadmap: see what the MBD Readiness Assessment covers.


Revisions, Purchase Orders and the Package Over Time

A package is released, superseded and withdrawn as a whole. When one file changes, every file gets the new revision, the manifest is rebuilt and the transmittal names what it supersedes. That rule sounds bureaucratic until a supplier machines revision C from the STEP file while inspecting against a revision B drawing.

Version the package, not the files. If we could put only one rule into your supplier quality manual, it would be this one. Three habits make it stick:

  • The purchase order references the package by part number, revision and manifest, never “the current CAD data”.
  • You archive an exact copy of what was sent. The checksums in the manifest prove which bytes left the building if a dispute comes up a year later.
  • Export settings are frozen per NX release. Designcenter 2606, the June 2026 NX release, came out on 23 June 2026, and Siemens ran the early access program for 2612 from 31 August to 25 September 2026. After every upgrade, export a reference part and run the five checks again before the next package goes out.

None of this needs a new system. It needs a written package specification per supplier tier and someone who owns it. inteliScience works on exactly this as a Siemens NX engineering partner from Cluj-Napoca, one hour ahead of CET, for design teams in the DACH region: we write the specification with your method owners, set up the TDP template and export settings in NX, and test the package with one real supplier before the next part class moves.


Frequently Asked Questions

What should an MBD supplier data package contain?

An MBD supplier data package should contain a STEP AP242 file with semantic PMI for CAM and CMM software, a 3D PDF or JT+PDF for people, a transmittal that names part number, revision, standard and the authoritative file, a manifest of all files, and evidence that the export was checked. A limited-dimension drawing is added while procedures still require a sheet, and native CAD files only by agreement. All files must come from one released revision.

How do you validate a STEP AP242 file before sending it to a supplier?

Open the exported file in a second application instead of trusting the CAD model. NIST’s free STEP File Analyzer and Viewer reports semantic PMI, graphic PMI and validation properties against the CAx-IF recommended practices. Geometric validation properties (volume, surface area, centroid) and PMI validation properties (counts of PMI elements, annotations and views) work as checksums the receiving system recomputes, and the CAx-IF lists 0.5 percent for volume and surface area as a well-proven industry threshold.

Which free viewers open STEP AP242, JT and 3D PDF files with PMI?

For STEP AP242, NIST’s STEP File Analyzer and Viewer is free and displays parts, assemblies, dimensions and tolerances; it runs on Windows. Siemens’ JT2Go is a free viewer for JT and Parasolid XT files on desktop, iOS and Android. A 3D PDF needs a PDF reader that renders embedded 3D content, which many browser-based viewers do not, so test with the reader your supplier actually uses.

STEP AP242 vs QIF: which format should carry MBD data to supplier inspection?

Use STEP AP242 as the product definition in the package, and add QIF only where both sides’ metrology software supports it. AP242 carries exact geometry and semantic PMI for any downstream system, while QIF (ISO 23952:2020) is an XML framework built for quality data such as measurement plans, results, part geometry and PMI. The two complement each other rather than compete: AP242 defines the part, QIF moves inspection data between metrology systems.

How much does it cost a supplier to work from an MBD data package instead of drawings?

Viewing costs nothing, because free viewers exist for STEP AP242, JT and 3D PDF. The cost sits in programming: CAM and CMM software that imports semantic PMI may need an upgrade or an add-on, priced by its vendor, plus training for programmers and inspectors. On the sending side, inteliScience’s fixed-price MBD Readiness Assessment (€4,900, one week, five sample parts) includes a supplier data package check with STEP AP242, JT and 3D PDF exports.


Next Step

Pick one part and the supplier who asks the most questions about it. In a free 60-minute call, inteliScience’s NX engineers look at what that supplier receives today, which file they really work from and what your package is missing. Talk to an NX engineer about your supplier data package



References

  • Trainer, Hedberg, Barnard Feeney, Fischer, Rosche, “Gaps Analysis of Integrating Product Design, Manufacturing, and Quality Data in the Supply Chain Using Model-Based Definition”, ASME MSEC2016, 27 June to 1 July 2016 (NIST publication): https://www.nist.gov/publications/gaps-analysis-integrating-product-design-manufacturing-and-quality-data-supply-chain (retrieved 9 October 2026)
  • Hedberg, Lubell, Fischer, Maggiano, Barnard Feeney, “Testing the Digital Thread in Support of Model-Based Manufacturing and Inspection”, ASME Journal of Computing and Information Science in Engineering 16(2), 2016 (NIST publication): https://www.nist.gov/publications/testing-digital-thread-support-model-based-manufacturing-and-inspection (retrieved 9 October 2026)
  • Gregorio, Lorch, Hughes, “Model Based Definition: Recommendations for Supply Chain Integration”, NPL Report MS 46, Issue 2, February 2023: https://doi.org/10.47120/npl.MS46 (retrieved 9 October 2026)
  • CAx-IF, “Recommended Practices for the Representation and Presentation of Product Manufacturing Information (PMI) (AP242)”, version 4.1 (20 June 2024), section 10 on PMI validation properties: https://www.mbx-if.org/home/wp-content/uploads/2024/06/rec_pracs_pmi_v41.pdf (retrieved 9 October 2026)
  • CAx-IF, “Recommended Practices for Geometric and Assembly Validation Properties”, version 4.6 (21 April 2023), section 4.13 on thresholds: https://www.mbx-if.org/home/wp-content/uploads/2024/05/rec_prac_gvp_v46.pdf (retrieved 9 October 2026)
  • NIST, STEP File Analyzer and Viewer (SFA): https://www.nist.gov/services-resources/software/step-file-analyzer-and-viewer, GitHub repository with release notes for versions 5.50 and 5.51: https://github.com/usnistgov/SFA (retrieved 9 October 2026)
  • NIST, Download Free CAD Models, STEP Files, and Test Results: https://www.nist.gov/ctl/smart-connected-systems-division/smart-connected-manufacturing-systems-group/mbe-pmi-0 (retrieved 9 October 2026)
  • Siemens Designcenter blog, Michael Hobson, “NX: How to move from drawing-based engineering to MBD” (12 February 2026): https://blogs.sw.siemens.com/designcenter/designcenter-nx-how-to-move-from-drawing-based-engineering-to-mbd/ (retrieved 9 October 2026)
  • Siemens PLM Software, “Realizing a Digital Enterprise driven by standards”, white paper (2017): https://www.plm.automation.siemens.com/media/global/en/Siemens%20PLM%20Realizing%20a%20Digital%20Enterprise%20driven%20by%20Standards_tcm27-62124.pdf (retrieved 9 October 2026)
  • Siemens, JT2Go: https://www.siemens.com/en-us/products/plm-components/jt/jt2go/ (retrieved 9 October 2026)
  • Digital Metrology Standards Consortium, Quality Information Framework (QIF), ISO 23952:2020: https://qifstandards.org/ (retrieved 9 October 2026)
  • Siemens NX Manufacturing blog, “Streamlining machining and quality inspection operations using PMI” (14 July 2021): https://blogs.sw.siemens.com/nx-manufacturing/streamlining-machining-and-quality-inspection-operations-using-pmi/ (retrieved 9 October 2026)
  • Siemens Designcenter blog, “What’s New in NX, NX Inspector and MBD” (December 2024 release): https://blogs.sw.siemens.com/designcenter/whats-new-in-nx-nx-inspector-and-mbd/ (retrieved 9 October 2026)
  • Siemens Designcenter blog, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 9 October 2026)
  • Siemens, “Welcome to the September 2026 Early Access Program for Designcenter” (Designcenter 2612, 31 August to 25 September 2026): https://resources.sw.siemens.com/en-US/presentation-welcome-to-designcenter-early-access-program/ (retrieved 9 October 2026)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.