Contacts
Get in touch
Close

Contacts

Romania, Cluj-Napoca – 400157
Str. Ploiești Nr. 9

Romania, Vama – 447350
Str. Fermei Nr. 14

+40 774 463 429

info@inteliscience.net

Connect PDM and ERP for AI Without Replacing Either

Connect PDM and ERP: The Short Version

To connect PDM and ERP for engineering AI, you read both systems, plus the wiki and the file servers, through their standard interfaces and link the records by one consistent project or order number. Nothing is replaced, nothing is written back. inteliScience builds this read-only layer for whatever CAD you run. The real effort is data quality, not technology.


The Problem: Four Systems, One Project, No Shared Key

A new RFQ arrives and the first question is always the same: have we built something like this before, and what did it cost? The answer exists. It is just spread over four places.

The design sits in the PDM. Costs, purchase orders and supplier history sit in the ERP. The reasons behind a design decision, and the lessons from commissioning, sit in a wiki. Specifications, test reports and customer correspondence sit on a file server, in a folder someone named years ago.

Each of these systems was introduced by a different team, for a different job, at a different time. None of them was designed to know what the others know.

An AI model does not change that on its own. A language model over one source answers questions about that one source. The value of engineering data AI (finding similar past projects, analyzing an incoming requirements specification against them, pulling real costs for a quotation) comes from the link between sources. This guide is about that link: how to build it without touching the systems themselves, and why the number on the project folder matters more than the choice of model.

What Each System Contributes to a Past-Project Record

Every source holds a different slice of the same project, and each has its own key. The table below is the map we start from. Note the last row: for metadata-based project search, the CAD system itself does not need to be connected at all.

Source What it knows about a past project Typical key Standard read path
PDM (commercial, or self-built on a SQL database)Part and assembly numbers, names, structure, revisions, project assignmentPart number, project attributeVendor API or read-only SQL access
ERP (e.g. SAP Business One, SAP S/4HANA, Proalpha, Microsoft Dynamics 365 Business Central)Articles, costs, purchase orders, suppliers, quotationsArticle number, sales order or project numberThe vendor’s standard REST or OData API
Wiki (e.g. Confluence or SharePoint)Design decisions, lessons learned, commissioning notesPage title, label, spaceConfluence REST API, Microsoft Graph
File server (Windows shares, NAS)Specifications, test reports, correspondence, exported drawingsFolder path, file nameRead-only share access
CAD (Siemens NX, CATIA, SolidWorks, Creo)GeometryModel fileNot needed for metadata search

Part and assembly numbers, names, structure and project assignment already live in the PDM. That keeps the integration CAD-neutral: NX plus whatever else your suppliers or acquired sites use. Finding parts that look alike is a different job. Geometric similarity works on shapes, not metadata, and needs a one-time index over the part library, which is a separate project with separate prerequisites.

Read-Only Integration: Connect PDM and ERP Without Replacing Either

You do not need a new platform, a migration or a data warehouse to connect PDM and ERP for AI. Mainstream ERPs offer a standard read interface, a PDM on a SQL database can be read directly, and wikis and file servers have standard connectors. The AI layer reads. It never writes back.

Our clear recommendation is read-only in phase one, without exceptions. It changes no validated process, needs no new interface owner, gets through IT security review faster, and can be switched off without side effects. Write-back can come later, if a use case truly needs it.

The ERP side is less exotic than it sounds. SAP Business One exposes its data through the Service Layer, built on HTTP and OData (version 3 under /b1s/v1, version 4 under /b1s/v2). Its user guide reached document version 1.29 on 27 July 2026, which extended the webhooks: a receiving system can now filter events and get key data in the notification, so it learns about changes without polling. Microsoft Dynamics 365 Business Central offers API v2.0 with a projects resource that carries a number and a display name. SAP S/4HANA publishes released OData APIs on the SAP Business Accelerator Hub. And Proalpha announced in April 2026 that it will rely on an API-centric reference architecture and REST interfaces going forward.

Two read-only lookups, one per ERP, show how little is involved:

# Read-only project lookups through standard ERP APIs (GET only, nothing is written)

# SAP Business One Service Layer, OData v4 (after POST /b1s/v2/Login)
GET https://erp-host:50000/b1s/v2/Projects?$select=Code,Name,ValidFrom&$filter=startswith(Code,'P-24')

# Microsoft Dynamics 365 Business Central, API v2.0
GET https://api.businesscentral.dynamics.com/v2.0/{tenant}/{environment}/api/v2.0/companies({companyId})/projects?$select=number,displayName

The same read path delivers article, cost and procurement data for every hit, which is what turns a list of similar projects into a usable reference for a quotation.

Wikis and file shares follow the same principle. The Confluence Cloud REST API v2 returns only the pages the calling user may view. In SharePoint, Microsoft Graph’s Sites.Selected scope grants an application access to named sites only, with a read role, and in delegated mode the application never exceeds the user’s own permissions. A Windows file share is read through an account with read rights and nothing else.

One delimitation. This is the opposite direction from CAD-to-ERP BOM sync, which writes released structures into the ERP. That is a legitimate project with its own risk profile, change control and owners. Linking for AI only reads, so it never competes with it. The read-only pattern described here is the base of everything we build under engineering data AI.

The Project Number Is the Linking Thread

The cheapest link between four systems is a number they already share: the project, order or commission number of an engineer-to-order job. If the same number appears on the PDM project, the ERP sales order, the wiki page and the folder on the file server, linking is a join. If it does not, linking is still solvable, but it becomes part of the project.

Situation in your data What linking looks like What drives the effort
Same number, same format in all four systemsDirect matchAccess rights and permissions, little else
Same number, different formats (P-24017, P24017, 24017-A)Agreed normalization rulesAgreeing on the rules with the data owners
Number missing in one source (e.g. wiki pages titled by topic)Derived links via folder paths, article overlap and dates, confirmed by an engineerReviewing ambiguous matches
Numbering scheme changed, e.g. after an ERP switchA mapping table, built onceBuilding the table and naming an owner for it

Part numbers are the second thread. Either the PDM part number and the ERP article number are identical, or there is a maintained field that maps one to the other. Where neither exists, a hit in the PDM cannot be priced from the ERP until someone builds that mapping.

Do not expect naming to be stable, even inside one vendor’s product. Business Central replaced the term “jobs” with “projects” in its interface and documentation from 1 April 2024, while the underlying table and field names stayed as they were. Your own systems will carry similar drift: a project in one tool is an order in the next and a commission folder in the third.

We would rather spend the first day tracing a handful of completed projects by hand through all four systems than write a single connector. That tracing tells you more about the effort ahead than any architecture slide.

Data Quality, Not Technology, Is the Real Effort

Reading four systems is standard engineering. Whether the data agrees with itself is not. That is the main uncertainty in projects of this kind, and it is why effort estimates made before anyone looks at the data are guesses.

The pattern is not specific to engineering. Gartner predicts that through 2026, organizations will abandon 60% of AI projects unsupported by AI-ready data, and in its survey of 248 data management leaders in the third quarter of 2024, 63% either lacked the right data management practices for AI or were unsure whether they had them.

In engineering data, the gaps have recognizable shapes. Projects copied from an older project carry the old number in the PDM. A numbering scheme changed with the last ERP migration and nobody kept the mapping. Wiki pages are titled by topic or by machine type instead of by project. The most useful file server folders belong to colleagues who have left. None of this is unusual, and none of it stops a project. It just has to be found before it is promised away.

To be precise about scope: this is not a cleanup of part classification or characteristics in the master data. It is about whether a record in one system can find its counterpart in the others.

Our advice is to resist the big data-cleansing program. Clean what the first use case needs and nothing more: one product family and a handful of completed projects. That is the scope of our NX Sprint, and the Quick Scan with an on-site workshop before it looks at exactly the questions below, on your data.

Data-Readiness Checklist: Seven Questions Before You Connect PDM and ERP

Answer these before anyone writes a connector. Each “no” is not a blocker. It is a line item in the plan.

  1. One number per job: Is there one project or order number that identifies a job from quotation to delivery, in one agreed format?
  2. PDM carries it: Is the number a field or attribute on the project or top-level assembly, not only part of a folder name?
  3. ERP carries it where it matters: Does it appear on the sales order or project, and on purchase orders and cost postings?
  4. Wiki and file server carry it: In page titles, labels or spaces, and in folder paths?
  5. Part and article numbers match: Identical in PDM and ERP, or mapped by a maintained field?
  6. Completed means completed: Is there a status that separates finished projects from open ones and from lost quotations?
  7. Read access has an owner: For each source, who grants a read-only account or role, and who decides which data the AI may see?

Questions 1 to 4 can be measured with a few exports. Export the project numbers from each source (a directory listing of the project folders is enough for the file server) and run a trace test like this one:

# Data-readiness trace test: which project numbers appear in every source?
# Input: one CSV export per source with a column "project".
import csv
import re
from pathlib import Path

SOURCES = ["pdm.csv", "erp.csv", "wiki.csv", "fileserver.csv"]

def normalize(raw):
    """'P-24017', 'p24017 ', '24017-A' -> '24017'. Adapt the pattern to your scheme."""
    match = re.search(r"(\d{5})", raw or "")
    return match.group(1) if match else None

numbers = {}
for name in SOURCES:
    with Path(name).open(newline="", encoding="utf-8") as f:
        values = {normalize(row["project"]) for row in csv.DictReader(f)}
    numbers[name] = {v for v in values if v}

in_all = set.intersection(*numbers.values())
in_any = set.union(*numbers.values())
print(f"{len(in_all)} of {len(in_any)} project numbers appear in all sources")
for name, values in numbers.items():
    gaps = sorted(in_any - values)[:10]
    print(f"{name}: {len(values)} numbers, first gaps: {gaps}")

If most numbers show up in all four sources, linking is mostly access work. If the intersection is small, the gap lists tell you which system breaks the thread, and whether a normalization rule or a mapping table will close it.

This trace runs as a POC on exports. What’s missing for production: access under each user’s own permissions, change detection instead of re-imports, citations back to the source record, and operation inside your own infrastructure. We take linked engineering data from a spreadsheet test to a search your engineers use daily: see how similar project search works on linked PDM and ERP data.


For Teamcenter and SAP specifically, our Teamcenter SAP integration page explains the standard connector, custom interfaces and how the transfer is tested.

Frequently Asked Questions

What is the difference between PDM and ERP?

PDM (product data management) manages engineering data: CAD models, drawings, part and assembly structures, revisions and release status. ERP (enterprise resource planning) manages the business side: articles, orders, costs, purchasing, inventory and production planning. In engineer-to-order work, every project lives in both, which is why linking them pays off.

Can you connect PDM and ERP without replacing either system?

Yes. Both can be read through standard interfaces, a vendor API or read-only database access for the PDM and the vendor’s REST or OData API for the ERP, while each system stays the master of its own data. For AI search and analysis, read-only access is enough; write-back is only needed for processes such as BOM transfer.

Through a shared key: either a maintained field that maps PDM part numbers to ERP article numbers, or the project or order number both systems carry. Where neither exists, links are derived from overlaps such as article lists, dates and folder paths, and an engineer confirms the ambiguous ones. The work lies in agreeing on the rules, not in the matching code.

How much does it cost to connect PDM and ERP for an AI project?

It depends mainly on data quality and on the number of sources, not on the interfaces, which are standard. If one project number runs consistently through every system, linking is a small part of the project; if it does not, building the mapping becomes the main effort. A bounded proof of value on one product family and a handful of completed projects gives a reliable estimate before any larger commitment.

Is it safe to give an AI system read access to ERP, SharePoint and Confluence data?

It can be, as long as the AI inherits the permissions of the source systems instead of bypassing them. The Confluence REST API returns only pages the calling user may view, and Microsoft Graph’s Sites.Selected scope limits an application to named SharePoint sites with a read role. Keep the index and the model inside your own infrastructure or private cloud, and log every query.


Next Step

Pick one completed project you know well and check whether its number shows up in all four places. Then talk to inteliScience: CAD-neutral engineers with deep Siemens NX roots, delivering nearshore from Romania for DACH manufacturers. We will tell you what a Quick Scan with an on-site workshop on your data would look at and where the thread is likely to break.

Talk to our engineers about linking PDM and ERP data



Sources

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.