Check-Mate Customization: Turn Company Rules Into NX Checks

Check-Mate Customization: The Short Version

Check-Mate customization turns written company design rules into checks Siemens NX runs on every part. You tune parameters and severities of standard checks, group them into profiles, and write new checkers in the Checker Editor, Knowledge Fusion or NX Open. inteliScience builds NX Open checkers, and as an official DOCUFY partner it also implements DQM when configuration is faster.

Customization level What you change Who usually does it Where Siemens documents it
Parameters and severityThreshold values of standard checks; information, warning or errorCAD administratorSet Up Tests, NX tips series (July 2023)
ProfilesWhich checkers run together, each child checker enabled or disabledCAD administratorNX Open reference, profile checkers
Checker EditorNew checker logic as a graph of nodes in the logic editorTrained power userJune 2023 release
Knowledge Fusion checkerA checker class written in NX’s rule languageKnowledge Fusion developerKnowledge Fusion help
NX Open checkerA checker written in C#, Python or another NX Open languageNX Open developerJune 2021 release, NX Open reference

The Problem: The Rule Exists, the Checker Does Not

Every NX organization has rules that no standard check knows: the approved material list, the attributes the title block reads, the layer template, the datum scheme for one part family. Check-Mate ships what Siemens describes as an extensive library of hundreds of standard checks across modeling, drafting, PMI, geometry, routing and welding, plus an authoring tool for custom checking functions. The library covers the generic rules. Your rules need customization.

In practice, this is where Check-Mate rollouts stall. The standard checks get switched on, a few thresholds get adjusted, and the company guideline stays a PDF because nobody owns the step from written rule to checker. The first half of that step, turning a guideline into an executable rule catalog with scope, severity and owner, is covered in our guide to making company design rules executable in Siemens NX. This article covers the second half: the Check-Mate mechanisms that turn one catalog entry into a check, with one working example per mechanism.

A note on names: with the June 2026 release, Siemens renamed Designcenter NX to Designcenter, announced on 23 June 2026, and its product pages say Designcenter Check-Mate. We keep the familiar names NX and Check-Mate here.

Five Levels of Check-Mate Customization, From Settings to Code

Start at the lowest level that can express the rule. Every level above it adds power and adds maintenance, and the maintenance is what decides whether a checker still runs two NX releases later. Our recommendation is blunt: never write code for a rule that a parameter on a standard check already covers.

Level 1: Parameters and severity in Set Up Tests

The cheapest customization is a setting. In Set Up Tests you choose the scope (the current part, all loaded parts, or all parts in a folder), pick checks from categories such as information, modeling, assemblies, PMI and requirements, and change the values each check tests for as well as whether a finding is reported as information, warning or error.

Working example: Siemens’ own tips series walks through the standard feature tolerance check, whose tolerance limit sits in the checker’s parameters and is visible under More Detail after a run. If your standard demands a tighter modeling tolerance than the default, the customization is one changed parameter and a severity raised from warning to error. No code, no deployment beyond the saved settings.

Level 2: Profiles that bundle checkers for one purpose

A profile is itself a checker that contains child checker instances, and each child can be enabled or disabled; the NX Open reference documents exactly this for profile checkers. Profiles are how you turn a pile of individual checks into something a designer can run with one click and a release process can rely on.

Working example: a “release” profile with the attribute checks, the feature tolerance check and the PMI checks at error severity, and a lighter “supplier data” profile for incoming geometry with the PMI checks disabled. The profile, not the single checker, is the unit you name, version and deploy.

Level 3: The Checker Editor (logic editor, since June 2023)

The June 2023 release introduced the Checker Editor, which authors Check-Mate checkers in the logic editor framework. Siemens’ stated goal was to reduce the need for language expertise when writing custom checkers. A checker becomes a graph of nodes connected by links: geometry nodes for primitives, solids and topology, input nodes for selections and values, utility, logic, list management and math nodes. Runtime debugging shows the data captured so far against the open model, and reusable snippets package logic you need in several checkers. Siemens added sample checkers and sample snippets to learn from (Siemens, What’s new in NX, June 2023, Validation).

Working example: the material rule from the worked example below is a small graph here, an input for the approved list, a node that reads the part attribute, a list node that tests membership, and a logic node that turns the answer into pass or fail. This is the right level for rules that a methods engineer should be able to read and change without a developer.

Level 4: Knowledge Fusion checkers

Knowledge Fusion is NX’s rule language, and before the Checker Editor and NX Open it was the way to write custom Check-Mate checkers: a checker class with parameters and check logic in a .dfa file, documented in the Knowledge Fusion help. Even the NX Open reference points to the Knowledge Fusion help for how checker parameters are customized, a reminder of where Check-Mate comes from. If your installation already holds Knowledge Fusion checkers, they are the natural home for closely related rules.

Working example: the same material rule as a Knowledge Fusion class carries the approved list as a parameter, reads the material attribute of the part, and logs a failed result with a message when the value is missing or not on the list. We would not start a new checker library in Knowledge Fusion today unless your team already maintains Knowledge Fusion code: it is a specialist language, while the Checker Editor needs no programming language and NX Open runs on mainstream ones such as C# and Python.

Level 5: NX Open checkers

Since the June 2021 release, Check-Mate checkers can be written in NX Open in every supported language, with all major Check-Mate functions: Set Up, Customize, Execute, Documentation, Save Results, smart checking and batch mode. Their results appear in HD3D and can be saved into Teamcenter. In the API, this lives in the NXOpen.Validate namespace: ValidationManager.CreateCheckerDefinition registers a checker class with its parameters and a handler that Check-Mate calls when it executes the checker, and a Logger records each result. This is the level for rules that need real geometry algorithms, data from outside the part, or code you want to test like any other software.

The worked example below uses it.

Worked Example: One Written Rule, End to End

The rule, as it stands in many guidelines: “Every part released to production carries a material from the approved list.” Here is how it becomes a Check-Mate checker, a profile entry and a release condition.

  1. Make it executable. Scope: every part in the release profile. Condition: the string attribute MATERIAL exists and its value is on the approved list. Severity: error. Owner: the materials or methods engineer who maintains the list. Exceptions: none in the checker; overrides are handled by governance (see below).
  2. Look for a standard check first. Check-Mate’s library is large. If a standard attribute check with a value list covers the rule, stop at Level 1.
  3. Pick the level. The list changes with purchasing decisions, so it must be a parameter, not hard-coded. We use NX Open here because the checker will later read the list from a controlled source.
  4. Implement it (code below), add it to the release profile, set the severity.
  5. Baseline in batch over existing parts before anyone is blocked (second code block).
  6. Gate the release by saving results to Teamcenter.

Step 4: the checker in NX Open (C#)

Every Check-Mate call below is documented in the Siemens NX Open .NET reference (classes ValidationManager, CheckerNode, Logger, Parameter and NXObject); the checker API requires the Check-Mate licence. We wrote it in C# because the reference documents these signatures in .NET; Siemens states that checkers can be written in every supported NX Open language, so a Python version uses the same classes.

// Rule M-01 (illustrative): every released part carries a MATERIAL attribute
// whose value is on the approved list. NX Open checker for Check-Mate.
using System;
using NXOpen;
using NXOpen.Validate;

public static class MaterialChecker
{
    const string ClassId = "cmp_material_approved";   // your own prefix
    const string ListParam = "approved_materials";     // ID and label kept identical

    // Run once per NX session, before Check-Mate lists or runs checkers.
    public static CheckerDefinition Register()
    {
        ValidationManager vm = Session.GetSession().ValidationManager;

        Parameter approved = vm.DefineParameter(
            ListParam,
            new string[] { "S235JR", "S355J2", "1.4301", "EN AW-6082" },
            new ValidationManager.ParameterOptions(ListParam, "Rule M-01", true));

        return vm.CreateCheckerDefinition(
            ClassId,
            "Material from approved list",
            "Company rules",
            new Parameter[] { approved },
            DoCheck);
    }

    // Called by Check-Mate when it executes this checker.
    static void DoCheck(CheckerNode node)
    {
        Logger log = node.AskLogger();
        string[] allowed = node.GetParameter(ListParam).GetStringValues();
        Part part = Session.GetSession().Parts.Work;   // the part under check

        if (!part.HasUserAttribute("MATERIAL", NXObject.AttributeType.String, -1))
        {
            log.LogNXObject(Validation.Result.Failed, part, "MATERIAL attribute missing");
            return;
        }

        string value = part.GetStringUserAttribute("MATERIAL", -1);
        if (Array.IndexOf(allowed, value) < 0)
            log.LogNXObject(Validation.Result.Failed, part,
                "Material '" + value + "' is not on the approved list");
        else
            log.LogResult(Validation.Result.Pass, "Material '" + value + "' approved");
    }
}

Three details matter more than the code. The approved list is a modifiable parameter, so a CAD administrator can adjust it per profile without a rebuild. The checker logs the part as the failing object, so the finding shows up in HD3D on the right object. And Register() has to run when NX starts, so the checker class exists before anyone opens Set Up Tests. How an NX Open checker library is deployed and loaded, and which part the handler sees as the part under check, is release-specific: take both from the Check-Mate documentation for the NX release you run, not from any blog, this one included.

Step 5: the baseline run over existing parts

Before the rule blocks anyone, run it over the parts that already exist and count the failures. The Validator class runs checkers or profiles over part files and returns the overall result; its options control what is saved where.

// Baseline: run a profile (or a single checker class) over a folder of parts.
// API: NXOpen.Validate.Validator and ValidatorOptions (NX Open .NET reference).
using System.IO;
using NXOpen;
using NXOpen.Validate;

public static class Baseline
{
    public static Validation.Result Run(string folder, string checkerClass)
    {
        Session s = Session.GetSession();
        string logDir = Path.Combine(folder, "checkmate_logs");
        Directory.CreateDirectory(logDir);

        Validator v = s.ValidationManager.CreateValidator("baseline_run");
        try
        {
            v.AppendCheckerNode(checkerClass);
            v.AppendPartNodes(Directory.GetFiles(folder, "*.prt"));

            ValidatorOptions o = v.ValidatorOptions;
            o.SkipChecking = false;      // baseline: check every part, even with up-to-date results
            o.SaveResultInPart = false;  // do not touch the parts
            o.SavePartFile = ValidatorOptions.SaveModeTypes.DoNotSave;
            o.SaveResultInTeamcenter = ValidatorOptions.SaveModeTypes.DoNotSave;
            o.GenerateLogFile = true;
            o.LogFileDirectory = logDir;

            return v.Commit();           // Pass, Information, Warning, Failed, Unknown or Skipped
        }
        finally
        {
            s.ValidationManager.DeleteValidator(v);
        }
    }
}

The failure rate from this run is the number the rule owner needs before the rule goes live. If half the vault fails, the rule text or the approved list is wrong, or the legacy strategy is missing; either way, you find out before designers do.

This checker runs on one workstation. What’s missing for production: Deployment to every NX seat, a regression set of passing and failing parts for each new NX release, profiles under version control, and results that land in Teamcenter as a release condition. We close that gap with custom NX quality checks built and maintained in NX Open, from the rule catalog to the release gate.

Step 6: the release gate

For the gate, the same options switch from baseline to enforcement: SaveResultInTeamcenter accepts DoNotSave, SaveIfPassed or AlwaysSave, SaveResultInPart stores results in the part file, and GenerateCheckFlag generates a check flag when the results are PASS. Siemens confirms that NX Open checker results can be saved into Teamcenter. Whether your release workflow reads that result, and blocks on it, is a Teamcenter workflow decision; we treat it as part of the same project, not an afterthought.

Where Check-Mate Results Land

Running a check is half of Check-Mate customization; deciding where the results go is the other half. Five destinations are documented.

Destination What it is good for Source
HD3D in the sessionFlow lists, visual tags, tooltips and see-through display on the failing objects; Show Info View and More Detail explain each resultSiemens product page and NX tips series
Part fileResults travel with the part (SaveResultInPart)NX Open reference
Log filesBatch evidence per run (GenerateLogFile, LogFileDirectory)NX Open reference
Quality DashboardSummary and custom reports, results per part file or per checker, graphs for trends; replaced the Java Qdashboard in 2021Siemens blog, 2021 and 2023
TeamcenterResults saved into Teamcenter as input for the release; Requirements Validation allocates requirements from Teamcenter and validates against themSiemens blog 2021, product page

Our advice: decide the destination before writing the first checker. A checker whose result only exists in one designer’s session is a hint, not a rule.

Governance: Owners, Versions and False Positives

Custom checkers are software that runs inside your release process, and they fail the way unowned software fails. Three decisions keep them alive.

Owners. Every rule has a business owner in methods or quality who decides what the rule says, and a technical owner who maintains the checker. In practice the two are rarely the same person, and the rule catalog should say who is who.

Versions. Checker code, Checker Editor graphs, Knowledge Fusion classes and profiles go into version control together with the rule catalog, and a profile version is deployed like an NX template, not copied around. Siemens follows a continuous release cycle, with the December 2025 and June 2026 releases as the two most recent, so keep a small regression set of parts, at least one passing and one failing part per rule, and run it against every new release before rollout.

False positives. Every checker produces findings that are technically correct and practically wrong: the legacy part, the prototype, the deliberate exception. Check-Mate has a documented answer: override requests. According to the NX Open reference, an override request carries a reason, a type (permanent or temporary), the state it sets the result to (passed or failed), and a decision by a Teamcenter user in the Validation Administration group; Teamcenter can make the detailed reason mandatory. Define who may decide which overrides, and review them per rule. A rule that is overridden on most parts is a wrong rule; fix the rule, not the parts.

When a Ready-Made Rule Set Such as DOCUFY DQM Is the Faster Path

Check-Mate customization is the right investment when your rules are specific, your team can own checkers through NX releases, and the licence already includes Check-Mate. It is not the fastest path when the catalog is long and mostly generic. Neither option is better in general; they are different operating models, and many organizations run both.

DOCUFY CAx Quality Manager (DQM) is a product fully integrated into Siemens NX that ships with more than 450 standardized and configurable best-practice checks, preconfigured routines that are usable out of the box, healing functions that correct deviations automatically for supported checks, and batch processing of large data volumes. Version 2026.1 of 30 March 2026 supports NX up to NX 2512, added seven base check routines and extended the Teamcenter integration, including writing properties to Item Revisions and datasets and reading and writing the Validation Master Form. DOCUFY promises that its 90-day evaluation package is ready to use after two days and includes training for later independent configuration.

Situation Faster path
Few, very company-specific rules; developer capacity in houseCheck-Mate customization
Rules that need custom geometry algorithms or external dataCustom NX Open checkers, whatever else you run
Long catalog of attribute, layer, drawing and PMI rulesDQM configuration
Findings pile up because correction is manualDQM healing for supported checks
Quality owner sits in methods, not IT, and wants configurationDQM
Routing, welding or other application-specific checksCheck-Mate standard library plus customization

The operating models are compared in detail in our DOCUFY DQM vs Siemens NX Check-Mate comparison. As an official DOCUFY partner, inteliScience also implements DQM; what it checks and how an evaluation works is on our DOCUFY CAx Quality Manager page. When a rule falls outside what DQM configuration can express, it remains custom work, and we say so before anyone buys a licence.

Frequently Asked Questions

What is Check-Mate Author in Siemens NX?

“Check-Mate Author” usually means the authoring side of Siemens NX Check-Mate, which Siemens’ product page describes as the authoring tool for creating custom checking functions. Since the June 2023 release the interactive way to author checkers is the Checker Editor in the logic editor framework; developers write checkers in Knowledge Fusion or, since June 2021, in NX Open.

Can you write Siemens NX Check-Mate checkers in NX Open with C# or Python?

Yes. Since the June 2021 release, Check-Mate checkers can be written in NX Open in all supported languages, with set up, customization, execution, documentation, result saving, smart checking and batch mode. The API is ValidationManager.CreateCheckerDefinition in the NXOpen.Validate namespace, and results appear in HD3D and can be saved into Teamcenter.

How do you run Siemens NX Check-Mate in batch mode on many parts?

Interactively, Set Up Tests can check the current part, all loaded parts or all parts in a folder. Programmatically, the NX Open Validator class appends checkers or profiles and part files, runs them with Commit(), and its options control log files, saving results in the part and saving results into Teamcenter.

Where is the official Siemens NX Check-Mate documentation for custom checkers?

The authoritative sources are the NX help for your release (Check-Mate and the Knowledge Fusion help, which has a Knowledge Fusion and NX Open section), the NX Open reference for the NXOpen.Validate namespace, and Siemens’ NX design blog for what changed per release. Use the documentation for the NX release you actually run, because menus and deployment details can change between releases.

How much effort is Check-Mate customization compared with configuring DOCUFY DQM?

Check-Mate customization costs developer time per rule plus maintenance for every NX release in Siemens’ continuous release cycle, while DQM starts from more than 450 configurable checks and DOCUFY promises its evaluation package is usable after two days. The real driver in both cases is the rule catalog: how many rules, how specific, and who owns them. A baseline run on your own parts sizes the effort better than any estimate.


Next Step

Bring one rule and a folder of parts. In an NX Sprint, inteliScience’s NX Open engineers, delivering from Romania for DACH engineering teams, turn a few of your written rules into Check-Mate checks, run the baseline over your parts and show you the failure rates, so you decide on facts whether to extend Check-Mate, configure DQM or combine both. Talk to our NX engineers about your Check-Mate rules



References

  • Siemens, “CAD design validation” (Designcenter product page: Check-Mate standard checks and authoring tool, Requirements Validation, HD3D Visual Reporting, DFMPro on the Check-Mate framework): https://www.siemens.com/en-us/products/designcenter/cad-software/mcad/design-validation/ (retrieved 3 September 2026)
  • Siemens NX Design blog, William Chanatry, “Ensure CAD Quality with NX Validation tools: What’s new” (25 August 2021): https://blogs.sw.siemens.com/designcenter/ensure-cad-quality-with-nx-validation-tools-whats-new/ (retrieved 3 September 2026)
  • Siemens NX Design blog, Shannon McGinty, “Out of the box validation checks, NX Tips and Tricks” (21 July 2023): https://blogs.sw.siemens.com/designcenter/learn-more-about-checks-with-out-of-the-box-testing-with-nx-check-mate/ (retrieved 3 September 2026)
  • Siemens NX Design blog, Shannon McGinty, “Quality Dashboard, NX Tips and Tricks” (7 August 2023): https://blogs.sw.siemens.com/designcenter/nx-tips-and-tricks-using-quality-dashboard-for-improving-design-workflows/ (retrieved 3 September 2026)
  • Siemens NX Design blog, Jamie Tyler, “What’s new in NX, June 2023, Validation” (11 August 2023): https://blogs.sw.siemens.com/designcenter/whats-new-in-nx-june-2023-validation/ (retrieved 3 September 2026)
  • Siemens NX Open .NET Reference (NX 1926), NXOpen.Validate.ValidationManager, CheckerNode, Logger, Validator, ValidatorOptions, OverrideBuilder and NXOpen.NXObject: https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09051.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09018.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09030.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09053.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09054.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a09034.html, https://docs.sw.siemens.com/documentation/external/PL20191127135844554/en-US/nx_api_sc/nx/1926/nx_api_sc/en_US/nxopen_net/a06909.html (retrieved 3 September 2026)
  • Siemens Designcenter blog, Jamie Tyler, “December 2025 release, Designcenter NX, Download now” (15 December 2025): https://blogs.sw.siemens.com/designcenter/december-2025-release-designcenter-nx-download-now/ (retrieved 3 September 2026)
  • Siemens Designcenter blog, Jamie Tyler, “Designcenter is for everyone, June 2026 release” (23 June 2026): https://blogs.sw.siemens.com/designcenter/designcenter-is-for-everyone-june-2026-release/ (retrieved 3 September 2026)
  • DOCUFY GmbH, “DOCUFY CAx Quality Manager” (product page): https://docufy.de/en/products/for-your-product-lifecycle-managementfuer-ihr-product-lifecycle-management/docufy-cax-quality-manager/ (retrieved 3 September 2026)
  • DOCUFY GmbH, “NX-Datenqualität sichern: Neue Version des DOCUFY CAx Quality Managers” (DQM 2026.1, 30 March 2026): https://docufy.de/nx-datenqualitaet-sichern-neue-version-des-docufy-cax-quality-managers/ (retrieved 3 September 2026)

Cookie settings

Choose which services we may use on this website. Your choice is stored in your browser for 12 months. You can change it at any time via “Cookie settings” at the bottom of every page.

Strictly necessary

Stores your cookie choice. This cookie cannot be switched off.

Always active
Show cookies
NameProviderPurposeStorage period
is_cookie_consentinteliScienceStores your cookie choice and when you made it12 months

Google Analytics 4 measures page views, traffic sources and form use with a pseudonymous ID. Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gaGoogleDistinguishes visitors with a pseudonymous ID2 years
_ga_<ID>GoogleStores the session state2 years

Google Ads measures which ads lead to enquiries (conversions) and lets us show our ads to previous visitors (remarketing). Provider: Google Ireland Ltd. Data may also be processed by Google LLC in the USA (EU–US Data Privacy Framework).

Show cookies
NameProviderPurposeStorage period
_gcl_au, _gcl_aw, _gcl_gsGoogleLinks ad clicks to enquiries90 days
_gcl_ls (local storage)GoogleLinks ad clicks to enquiries90 days
IDE (doubleclick.net)GoogleRemarketing and ad measurement13 months

Videos: YouTube videos only load when you press play (via youtube-nocookie.com). Only then does Google receive data.