CATIA to NX: The Short Version
Going from CATIA to NX, experienced designers keep their modeling judgment but relearn where things live: the specification tree becomes the Part Navigator, publications become Product Interface plus WAVE links, and products become assemblies stored as .prt files. inteliScience sets up NX standards first, then trains switching teams on their own parts.
The Problem: CATIA Experts Become NX Beginners on a Customer’s Deadline
A CATIA to NX switch rarely starts as an internal choice. A customer, often an OEM consolidating its supply chain on one CAD platform, asks for native NX data from a given program onward. The date comes from the customer’s program plan, so the people who carry your output must relearn their tool while still delivering.
The skills that make a senior CATIA designer valuable transfer completely: design intent, sketch discipline, a feel for surface quality, GD&T, knowing what the shop floor can actually make. What does not transfer is ten or fifteen years of muscle memory and vocabulary. The middle mouse button pans in CATIA and rotates in NX. A “publication” has no menu entry of that name. The tree on the left looks familiar and behaves differently.
The dangerous phase is not day one.
It is week four, when the first NX assembly with interpart links goes through its first engineering change and something moves that nobody expected to move.
One naming note before we start. With the June 2026 release (version 2606), Siemens renamed Designcenter NX to Designcenter, and it previewed the next version, 2612, in its September 2026 Early Access Program. Customer requirements, job ads and most engineers still say NX, and so does this guide. On the other side, Dassault Systèmes still ships CATIA V5 as V5-6R2026 next to 3DEXPERIENCE CATIA, so many suppliers will run both systems for years.
CATIA to NX Terminology: What Maps and What Only Looks Similar
Most CATIA V5 concepts have an NX counterpart, but few are one-to-one. Commands map easily (Pad and Pocket become Extrude); organizing concepts do not (geometrical sets, publications, products). The table lists the mappings experienced users ask about in their first week, plus what actually changes in daily work.
| CATIA V5 | Siemens NX | What changes in practice |
|---|---|---|
| Workbench (Part Design, Generative Shape Design, Drafting) | Application (Modeling, Shape Studio, Drafting) | An application changes the commands on offer, not the file |
| Specification tree | Part Navigator (parts), Assembly Navigator (assemblies) | Two navigators; the Part Navigator lists features in timestamp order |
| Define In Work Object | Make Current Feature | Later features turn inactive until you update to the end |
| PartBody and bodies | Solid bodies, several per part | No default PartBody; the Boolean is an option inside Extrude, Revolve and similar commands |
| Pad, Pocket | Extrude with Unite or Subtract | One command, the Boolean setting decides |
| Geometrical set, ordered geometrical set | Feature group plus layers and categories | Visibility follows a layer standard, not tree folders |
| Parameters and formulas | Expressions | Expressions can reference other parts (interpart expressions) |
| Design table | Part family (spreadsheet-driven) | Family members are generated as separate part files |
| Publications | Product Interface plus WAVE Geometry Linker | Declaring what may be linked and creating the link are two steps |
| CATProduct, instance | Assembly (.prt), component | Parts, assemblies and drawings are all .prt files |
| Activating a part inside a product | Make Work Part, Make Displayed Part | Edits go to the work part, which need not be the part on screen |
| Visualization mode, cgr cache | Reference sets, load options | Reference sets decide what a parent assembly sees of a part |
| Remove Face, Replace Face on imported solids | Synchronous Modeling (Move Face, Delete Face) | Imported geometry can be edited without any feature history |
| CATDrawing | Drawing in its own master-model .prt | The drawing part holds the model as a component |
| Functional Tolerancing & Annotation (FT&A) | PMI | Annotations live on the 3D model and in model views |
| VBA and CATScript macros, CAA | Journals and NX Open (Python, C#, VB.NET, C++) | Macros are rewritten, never converted |
Two rows cause most of the trouble: publications and the work part. Single commands are the easy part. Siemens’ own three-day course, NX FastStart for CATIA Users, spends a large share of its agenda on organizing models, linking geometry and expressions between parts, assemblies and data migration, and we think that is the right weighting.
Mindset Differences That Matter More Than Menus
Menus take a week. The four mindset shifts below take longer, because they change how a model is organized and how parts talk to each other. CATIA users who get them right early build NX models their colleagues can change later; the ones who skip them build CATIA-shaped models inside NX.
Specification Tree vs Part Navigator
In CATIA, the specification tree doubles as your filing system. Bodies, geometrical sets and ordered geometrical sets hold wireframe, surfaces and solids in folders you name and arrange.
The NX Part Navigator is a history first. Every feature carries a timestamp, and the order of creation is the order of update. To insert a feature earlier, you use Make Current Feature on its predecessor, create the new feature, then update to the end. Dragging a feature to another position works only as long as nothing it references was created later.
Organization moves elsewhere. Feature groups can bundle related features (Siemens’ Content Migration Manager (CMM) turns CATIA geometrical sets into feature groups, as Siemens describes for CATIA migrations), but visibility in NX is managed with layers 1 to 256 and the layer categories defined in your template. If your company has no layer standard yet, write it before the first CATIA user opens NX.
Publications vs WAVE Links
This is the concept CATIA power users ask about first, and the one where wrong habits cost the most. A CATIA publication does two jobs at once: it names an element as an official interface and makes it available to other parts. NX separates the two. Product Interface declares which objects of a part may be referenced from outside. The WAVE Geometry Linker then creates the associative copy in the target part, and interpart expressions do the same for values.
Our clear recommendation is a written WAVE policy before the first assembly with interpart links. It fits on one page:
- Link only to objects declared as Product Interface (NX can be set to restrict WAVE selection to them).
- Links run downward from a skeleton or control part, never sideways between sibling components.
- Fix at Current Timestamp is a deliberate choice, documented in the feature name, not a default someone clicked.
- Every linked feature is named so the source part is obvious in the Part Navigator.
Teams that let each engineer improvise end up with circular and broken links that only the original author can repair, and that author is usually the one person you cannot spare in week six.
Products vs Assemblies
A CATProduct is its own file type. In NX, an assembly is a .prt file like any part, and one part file can hold components, geometry and a drawing at the same time.
Two NX concepts have no direct CATIA twin. The work part is the part that receives your edits; the displayed part defines what is on screen. Double-clicking a component makes it the work part while the assembly stays displayed, which is how in-context design works in NX. NX then offers Save, Save Work Part Only and Save All, and new users lose changes, or save changes they did not intend, until they know which is which.
Reference sets are the second concept. They decide what a parent assembly sees of a part: Model (solid bodies only, maintained automatically), Entire Part (everything, including sketches and datums) or Empty (nothing, used for large-assembly performance). Constraints map more directly: CATIA coincidence, contact and offset constraints become NX assembly constraints such as Touch Align, Concentric and Distance, listed in the Constraint Navigator.
Parameters vs Expressions
CATIA parameters and formulas become NX expressions: named values, formulas and conditions that drive features. Every dimension you type in NX creates an expression, auto-named p0, p1 and so on unless you name it, so the CATIA habit of naming key parameters carries over well.
To see what a converted or inherited part really contains, a short NX Open journal is faster than clicking through the navigator. This one lists the feature history in timestamp order and all expressions of the work part, using only standard NX Open Python calls:
# List feature history and expressions of the current work part.
# Save as list_history.py and run it via File > Execute > NX Open (Ctrl+U).
import NXOpen
def main():
session = NXOpen.Session.GetSession()
work_part = session.Parts.Work
lw = session.ListingWindow
lw.Open()
if work_part is None:
lw.WriteLine("No work part loaded.")
return
lw.WriteLine(f"Part: {work_part.Leaf}")
lw.WriteLine("--- Features in timestamp order (Part Navigator) ---")
features = sorted(work_part.Features.GetFeatures(), key=lambda f: f.Timestamp)
for feat in features:
state = "suppressed" if feat.Suppressed else "active"
lw.WriteLine(f"{feat.Timestamp:4d} {feat.FeatureType:<20} {feat.GetFeatureName():<32} {state}")
lw.WriteLine("--- Expressions (CATIA: parameters and formulas) ---")
for expr in work_part.Expressions:
lw.WriteLine(f"{expr.Name:<24} = {expr.RightHandSide}")
if __name__ == "__main__":
main()
On a part that came through a feature-based migration, the output shows at a glance which features arrived as real NX features and which ones fell back to plain bodies.
First-Week Pitfalls for CATIA Users in NX
The first-week mistakes are predictable, which makes them cheap to prevent. None is about a missing command. They come from habits that are correct in CATIA and wrong in NX, and each one is easier to fix with a template, a rule or ten minutes of mentoring than with a training slide.
- Fighting the mouse. The middle button rotates in NX and pans in CATIA. Pan is Shift plus middle button (or middle plus right button), zoom is Ctrl plus middle button or the wheel. We’d advise against hunting for a CATIA-style emulation: every NX colleague, course and video assumes the defaults.
- Editing the wrong part. In an assembly, the work part gets the edit. Check which component is the work part in the Assembly Navigator before every in-context change.
- Rebuilding geometrical sets on random layers. Without a layer and category standard in the template, each engineer invents one.
- Linking without a policy. WAVE links between sibling components feel like publications and turn into circular references at the first change.
- Ignoring reference sets. Sketches and datum planes clutter the assembly, or components seem to vanish because they were loaded with Empty.
- Putting the drawing into the model file. NX allows it, but a drawing in its own master-model part keeps model and drawing releases apart, and that is what most NX shops expect.
- Rebuilding every imported part. Converted CATIA parts without history can often be changed with Synchronous Modeling. Rebuild with features only the parts that will keep changing.
AI helps in this phase, as an add-on. Siemens’ in-product assistant, Design Copilot NX, answers “where is this command” questions well. It does not know your layer standard or your WAVE policy, though, so it complements a mentor rather than replacing one.
How Teams Switch From CATIA to NX Under an OEM Mandate Without Losing Output
Keep output stable by switching people in waves and data by need. Standards come first, then a pilot group trained on real parts, then mentored work on new, low-risk parts, while experienced CATIA users keep delivering release-critical work. Bulk data conversion waits until you know which parts will actually change in NX.
Start with what the customer actually requires. Native NX data in a specific NX release, an exchange process through Teamcenter, or JT and STEP AP242 for downstream use: each answer changes how far your switch must go and how fast.
| Phase | Timing | What happens | What protects output |
|---|---|---|---|
| 0. Standards | 2 to 4 weeks before training | NX templates for part, assembly and drawing; layer and category standard; reference-set rules; WAVE policy; attribute mapping to the PDM | Nobody models in NX without the company template |
| 1. Pilot training | Week 1 | Training for 4 to 6 engineers, on your own parts instead of demo blocks | The rest of the team keeps delivering in CATIA |
| 2. Mentored work | Weeks 2 to 6 | The pilot group builds new parts and one linked assembly in NX; short daily review with an NX expert | Release-critical work stays with experienced users until reviewed |
| 3. Data decision | In parallel | Sort CATIA data: keep in CATIA, convert as geometry, migrate with history or rebuild | Only data that will change in NX gets converted |
| 4. Rollout | After the pilot | Next groups trained; pilot engineers become internal contacts | A cut-over rule per program or part family |
The order matters more than the durations. Teams that train first and write standards afterwards spend the second month cleaning up the models built in the first.
In practice, the side-by-side period only works with a hard rule: per program or part family, one system is authoritative, and nobody edits the same part in both. At inteliScience, a Siemens NX engineering partner based in Cluj-Napoca, we put that rule into phase 0 together with the templates, because it is the part teams most often leave implicit. If you want an outside view on templates and standards before the pilot starts, that is the kind of work our Siemens NX consulting covers.
One engineer working through this guide is a pilot. A production switch needs more: NX templates and a WAVE policy before day one, training on your own parts, a decision on which CATIA data to convert, and an NX engineer to call when the first linked assembly misbehaves. We run CATIA to NX training on your own parts for teams of up to six.
What to Do With Existing CATIA Data
Not every CATIA file needs to become an NX file. Released parts that will never change can stay in CATIA or move as neutral geometry. Parts that will change need editable data, either migrated with feature history or rebuilt. The decision per part family drives cost more than the conversion tool does.
| Option | What arrives in NX | Fits when |
|---|---|---|
| Keep in CATIA | Nothing; CATIA licenses stay for changes | Legacy programs close to end of production |
| Convert as geometry (direct translator, STEP AP242, JT) | Solids, surfaces and structure, no feature history | Parts that rarely change; edits via Synchronous Modeling |
| Migrate with history (feature-based tools such as Siemens Content Migration Manager (CMM)) | NX features, feature groups from geometrical sets, most links if all referenced files are included; failed features as B-rep bodies | Part families that will keep changing |
| Rebuild in NX | A clean native model on your templates | Key parts, master models, anything with complex WAVE links |
We’d advise against converting the whole archive on day one. A sample tells you more: convert 30 to 50 representative files, look at what survives, then decide per part family. Our NX Migration Check does exactly that on up to 50 parts and assemblies, including a template gap list, an effort range for the full migration and a training plan for the switching users.
Whatever route you take, validate the converted data before people build on it. The checks that matter (closed solids, attributes, PMI, drawings that regenerate) are in our guide to CAD data quality after a migration.
For the broader decision, the Siemens NX vs CATIA comparison looks at modeling, data management and CAM side by side.
Frequently Asked Questions
How long does it take an experienced CATIA user to become productive in Siemens NX?
The basics take days, a productive routine takes weeks. Siemens’ own transition course, NX FastStart for CATIA Users, runs three days and covers the interface, part modeling, assemblies, interpart links, drawings, PMI and data migration. We recommend planning another four to six weeks of mentored work on real, low-risk parts before a CATIA expert takes over release-critical assemblies in NX alone.
What is the difference between CATIA publications and WAVE links in Siemens NX?
A CATIA publication names an element as an interface and makes it available to other parts in one step. Siemens NX splits this into Product Interface, which declares what may be referenced, and the WAVE Geometry Linker, which creates the associative copy in the target part; interpart expressions do the same for values. In both systems, a written rule about who may link to what matters more than the command itself.
Can CATIA V5 models be converted to Siemens NX with their feature history?
Partly. Feature-based migration tools such as Siemens Content Migration Manager (CMM) rebuild CATIA V5 features as NX features, turn geometrical sets into feature groups and keep most links when all referenced files are included, while features that fail arrive as B-rep bodies that need repair. Direct translators, STEP AP242 and JT bring solids and structure without history. Convert a representative sample first, then decide per part family.
How much does Siemens NX training for CATIA users cost in 2026?
Public DACH list prices for Siemens NX courses (October 2026) start at about €690 per day for a single live-online participant and reach about €2,000 per day for an in-house group of up to six, both plus VAT; Siemens’ own CATIA transition course runs three days. inteliScience quotes in-house and live online CATIA to NX training after a short call, based on modules and group size. Data migration is priced separately.
Can a team use CATIA V5 and Siemens NX side by side during a CATIA to NX switch?
Yes, and many suppliers do for a while, because legacy programs still need changes in CATIA. It works when one system is authoritative per program or part family and nobody edits the same part in both. Without that rule, the same part exists twice, both versions get changed, and nobody can say which one is released.
Next Step
If a customer has set a date for native NX data, the most useful next hour is one that sorts your situation: how many engineers, which programs, which data must move and by when. inteliScience NX engineers go through that with you and tell you plainly whether you need training, migration, standards work or just a plan.